Padraig Looney

Padraig Looney

Auto-generated profile, based on publicly available information

Padraig Looney

Mirada Medical Ltd., Oxford, United Kingdom

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
PLPadraig Looney
Padraig Looney
YYYi Yin
Yi Yin
SCSally L. Collins
Sally L. Collins
KNKypros H. Nicolaides
Kypros H. Nicolaides
WPWalter Plasencia
Walter Plasencia
GSGordon Stevenson
Gordon Stevenson
Volumetric placental measurement using 3-D ultrasound has proven clinical utility in predicting adverse pregnancy outcomes. However, this metric cannot currently be employed as part of a screening test due to a lack of robust and real-time segmentation tools. We present a multiclass (MC) convolutional neural network (CNN) developed to segment the placenta, amniotic fluid, and fetus. The ground-truth data set consisted of 2093 labeled placental volumes augmented by 300 volumes with placenta, amniotic fluid, and fetus annotated. A two-pathway, hybrid (HB) model using transfer learning, a modified loss function, and exponential average weighting was developed and demonstrated the best performance for placental segmentation (PS), achieving a Dice similarity coefficient (DSC) of 0.84- and 0.38-mm average Hausdorff distances (HDAV). The use of a dual-pathway architecture improved the PS by 0.03 DSC and reduced HDAV by 0.27 mm compared with a naïve MC model. The incorporation of exponential weighting produced a further small improvement in DSC by 0.01 and a reduction of HDAV by 0.44 mm. Per volume inference using the FCNN took 7-8 s. This method should enable clinically relevant morphometric measurements (such as volume and total surface area) to be automatically generated for the placenta, amniotic fluid, and fetus. The ready availability of such metrics makes a population-based screening test for adverse pregnancy outcomes possible.

14 May 2022 in Physics and Imaging in Radiation Oncology
Verified
Journal Article
Open access
FVFemke Vaassen
Femke Vaassen
DBDjamal Boukerroui
Djamal Boukerroui
PLPadraig Looney
Padraig Looney
RCRichard Canters
Richard Canters
KVKarolien Verhoeven
Karolien Verhoeven
WEWouter van Elmpt
Wouter van Elmpt
User-adjustments after deep-learning (DL) contouring in radiotherapy were evaluated to get insight in real-world editing during clinical practice. This study assessed the amount, type and spatial regions of editing of auto-contouring for organs-at-risk (OARs) in routine clinical workflow for patients in the thorax region. A total of 350 lung cancer and 362 breast cancer patients, contoured between March 2020 and March 2021 using a commercial DL-contouring method followed by manual adjustments were retrospectively analyzed. Subsampling was performed for some OARs, using an inter-slice gap of 1–3 slices. Commonly-used whole-organ contouring assessment measures were calculated, and all cases were registered to a common reference shape per OAR to identify regions of manual adjustment. Results were expressed as the median, 10th-90th percentile of adjustment and visualized using 3D renderings. Per OAR, the median amount of editing was below 1 mm. However, large adjustments were found in some locations for most OARs. In general, enlarging of the auto-contours was needed. Subsampling DL-contours showed less adjustments were made in the interpolated slices compared to simulated no-subsampling for these OARs. The real-world performance of automatic DL-contouring software was evaluated and proven useful in clinical practice. Specific regions-of-adjustment were identified per OAR in the thorax region, and separate models were found to be necessary for specific clinical indications different from training data. This analysis showed the need to perform routine clinical analysis especially when procedures or acquisition protocols change to have the best configuration of the workflow.

7 October 2023 in Physica Medica
Verified
Journal Article
Open access
FVFemke Vaassen
Femke Vaassen
CZCatharina M.L. Zegers
Catharina M.L. Zegers
DHDavid Hofstede
David Hofstede
MWMart Wubbels
Mart Wubbels
HBHilde Beurskens
Hilde Beurskens
WEWouter van Elmpt
Wouter van Elmpt
Atlas-based and deep-learning contouring (DLC) are methods for automatic segmentation of organs-at-risk (OARs). The European Particle Therapy Network (EPTN) published a consensus-based atlas for delineation of OARs in neuro-oncology. In this study, geometric and dosimetric evaluation of automatically-segmented neuro-oncological OARs was performed using CT- and MR-models following the EPTN-contouring atlas. Image and contouring data from 76 neuro-oncological patients were included. Two atlas-based models (CT-atlas and MR-atlas) and one DLC-model (MR-DLC) were created. Manual contours on registered CT-MR-images were used as ground-truth. Results were analyzed in terms of geometrical (volumetric Dice similarity coefficient (vDSC), surface DSC (sDSC), added path length (APL), and mean slice-wise Hausdorff distance (MSHD)) and dosimetrical accuracy. Distance-to-tumor analysis was performed to analyze to which extent the location of the OAR relative to planning target volume (PTV) has dosimetric impact, using Wilcoxon rank-sum tests. CT-atlas outperformed MR-atlas for 22/26 OARs. MR-DLC outperformed MR-atlas for all OARs. Highest median (95 %CI) vDSC and sDSC were found for the brainstem in MR-DLC: 0.92 (0.88-0.95) and 0.84 (0.77-0.89) respectively, as well as lowest MSHD: 0.27 (0.22-0.39)cm. Median dose differences (ΔD) were within ± 1 Gy for 24/26(92 %) OARs for all three models. Distance-to-tumor showed a significant correlation for ΔDmax,0.03cc-parameters when splitting the data in ≤ 4 cm and > 4 cm OAR-distance (p < 0.001). MR-based DLC and CT-based atlas-contouring enable high-quality segmentation. It was shown that a combination of both CT- and MR-autocontouring models results in the best quality.

11 January 2019 in Journal of Open Source Software
Verified
Journal Article
Open access
PDF file
PLPádraig Looney
Pádraig Looney
GSGordon Stevenson
Gordon Stevenson
SCSally Collins
Sally Collins
The Kretzfile format is used to store 3D ultrasound data, from GE Voluson ultrasound scanners. The geometry used in these hies is a toroidal coordinate system. Cartesian coordinates are required to allow application of advanced image libraries like ITK and scikit-image.

13 January 2015 in Journal of Digital Imaging
Verified
Journal Article
Closed access
PDF file
PLP. Looney
P. Looney
MHM. D. Halling-Brown
M. D. Halling-Brown
JOJ. M. Oduko
J. M. Oduko
KYK. C. Young
K. C. Young

1 November 2021 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
Verified
Journal Article
Open access
PDF file
SZS. Zieminski
S. Zieminski
SMStuart W.S. MacDonald
Stuart W.S. MacDonald
PLP. Looney
P. Looney
YWY. Wang
Y. Wang
Purpose/Objective(s) Cranio-spinal irradiation (CSI) using advanced modality (IMRT, VMAT, protons) requires contouring of the thecal sac, a tedious and time-consuming task. Additionally, sparing of the vertebrae to improve growth and bone marrow reserve necessitates vertebrae contours. The COG and other investigators have great interest in studying growth effects from vertebrae-sparing technique; this effort requires reporting of dose to the thecal sac and the vertebrae. The presence of bone-soft tissue interface and time required for manual contours make this an ideal use of deep-learning auto-contouring. Materials/Methods Two convolutional neural network (CNN) models were trained and validated, one with 65 patients to auto contour thecal sac, kidneys and lungs, and the other with 55 to draw vertebrae. The training set consisted of mostly pediatric and young adult patients. The models were tested on ten new patients at the age of 5, 6, 8, 9, 11, 13, 16, 20, 31 and 47. Quantitatively, auto contours were evaluated against clinical manual contours using dice similarity coefficient (DSC) and mean distance to agreement (MDA). A qualitative scoring system was used by a dosimetrist experienced in CSI contouring: 0 (accepted upright), 1 (accepted, minor editing in 1 min), 2 (accepted, moderate editing in 3 min), 3 (accepted, significant editing with efficiency gain) and 4 (rejected, gross error or no efficiency gain). The time for editing each auto contour for each patient was recorded and compared to the time required for manual contouring measured using time/slice and the number of slices for thecal sac, vertebrae and each kidney, and as whole organ for each lung. Results As shown in Table 1, on average, the DSC was above 0.90 and MDA below 1.2 mm, both well within the tolerance recommended by AAPM TG 132. The mean score was below 1.0 for all volumes. Editing thecal sac and vertebrae auto contours only required 1 min or less for all patients. The models reduced contouring time by 84 and 40 min for thecal sac and vertebrae, respectively. Conclusion The deep-learning models provided high-quality auto contours, directly acceptable for lungs and requiring only minor editing in less than one min for thecal sac, vertebrae and kidneys. Given the labor-intensive nature of manually contouring thecal sac and vertebrae, the high accuracy of the auto contours resulted in substantial reduction of contouring time and thus faster turnaround for CSI treatment. The models can provide a uniform starting point for CSI contouring in our field, which is particularly beneficial to clinics with less experiences.