Yi Yin

Yi Yin

Auto-generated profile, based on publicly available information

Yi Yin

Nuffield Department of Women's and Reproductive Health University of Oxford Oxford UK

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2012 in Pattern Recognition
Verified
Journal Article
Closed access
YYYi Yin
Yi Yin
MAMouloud Adel
Mouloud Adel
SBSalah Bourennane
Salah Bourennane

8 December 2013 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
YYYi Yin
Yi Yin
MAMouloud Adel
Mouloud Adel
SBSalah BOURENNANE
Salah BOURENNANE
The automatic analysis of retinal blood vessels plays an important role in the computer-aided diagnosis. In this paper, we introduce a probabilistic tracking-based method for automatic vessel segmentation in retinal images. We take into account vessel edge detection on the whole retinal image and handle different vessel structures. During the tracking process, a Bayesian method with maximum a posteriori (MAP) as criterion is used to detect vessel edge points. Experimental evaluations of the tracking algorithm are performed on real retinal images from three publicly available databases: STARE (Hoover et al., 2000), DRIVE (Staal et al., 2004), and REVIEW (Al-Diri et al., 2008 and 2009). We got high accuracy in vessel segmentation, width measurements, and vessel structure identification. The sensitivity and specificity on STARE are 0.7248 and 0.9666, respectively. On DRIVE, the sensitivity is 0.6522 and the specificity is up to 0.9710.

25 May 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
PLPadraig Looney
Padraig Looney
YYYi Yin
Yi Yin
SCSally L. Collins
Sally L. Collins
KNKypros H. Nicolaides
Kypros H. Nicolaides
WPWalter Plasencia
Walter Plasencia
GSGordon Stevenson
Gordon Stevenson
Volumetric placental measurement using 3-D ultrasound has proven clinical utility in predicting adverse pregnancy outcomes. However, this metric cannot currently be employed as part of a screening test due to a lack of robust and real-time segmentation tools. We present a multiclass (MC) convolutional neural network (CNN) developed to segment the placenta, amniotic fluid, and fetus. The ground-truth data set consisted of 2093 labeled placental volumes augmented by 300 volumes with placenta, amniotic fluid, and fetus annotated. A two-pathway, hybrid (HB) model using transfer learning, a modified loss function, and exponential average weighting was developed and demonstrated the best performance for placental segmentation (PS), achieving a Dice similarity coefficient (DSC) of 0.84- and 0.38-mm average Hausdorff distances (HDAV). The use of a dual-pathway architecture improved the PS by 0.03 DSC and reduced HDAV by 0.27 mm compared with a naïve MC model. The incorporation of exponential weighting produced a further small improvement in DSC by 0.01 and a reduction of HDAV by 0.44 mm. Per volume inference using the FCNN took 7-8 s. This method should enable clinically relevant morphometric measurements (such as volume and total surface area) to be automatically generated for the placenta, amniotic fluid, and fetus. The ready availability of such metrics makes a population-based screening test for adverse pregnancy outcomes possible.

27 April 2017 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YYYi Yin
Yi Yin
OSOliver Sedlaczek
Oliver Sedlaczek
BMBenedikt Muller
Benedikt Muller
AWArne Warth
Arne Warth
MGMargarita González-Vallinas
Margarita González-Vallinas
DDDirk Drasdo
Dirk Drasdo
Diffusion-weighted magnetic resonance imaging (DWI) is a key non-invasive imaging technique for cancer diagnosis and tumor treatment assessment, reflecting Brownian movement of water molecules in tissues. Since densely packed cells restrict molecule mobility, tumor tissues produce usually higher signal (a.k.a. less attenuated signal) on isotropic maps compared with normal tissues. However, no general quantitative relation between DWI data and the cell density has been established. In order to link low-resolution clinical cross-sectional data with high-resolution histological information, we developed an image processing and analysis chain, which was used to study the correlation between the diffusion coefficient (D value) estimated from DWI and tumor cellularity from serial histological slides of a resected non-small cell lung cancer tumor. Color deconvolution followed by cell nuclei segmentation was performed on digitized histological images to determine local and cell-type specific 2d (two-dimensional) densities. From these, the 3d cell density was inferred by a model-based sampling technique, which is necessary for the calculation of local and global 3d tumor cell count. Next, DWI sequence information was overlaid with high-resolution CT data and the resected histology using prominent anatomical hallmarks for co-registration of histology tissue blocks and non-invasive imaging modalities' data. The integration of cell numbers information and DWI data derived from different tumor areas revealed a clear negative correlation between cell density and D value. Importantly, spatial tumor cell density can be calculated based on DWI data. In summary, our results demonstrate that tumor cell count and heterogeneity can be predicted from DWI data, which may open new opportunities for personalized diagnosis and therapy optimization.

14 July 2015 in The Journal of Pathology
Verified
Journal Article
Closed access
PDF file
BMBenedikt Müller
Benedikt Müller
MBMichael Bovet
Michael Bovet
YYYi Yin
Yi Yin
DSDamian Stichel
Damian Stichel
MMMona Malz
Mona Malz
KBKai Breuhahn
Kai Breuhahn

25 August 2020 in EMJ Reproductive Health
Verified
Journal Article
Open access
PDF file
PDPedro H. B. Diniz
Pedro H. B. Diniz
YYYi Yin
Yi Yin
SCSally Collins
Sally Collins
In medical imaging, the most commonly employed deep learning methods are convolutional neural networks (CNN).1-8 Compared to classical machine learning...