The great interest shown today in the double-fed induction generator in wind chain prompted us to analyze the performance of the separate control of active and reactive power generated by the stator of double-fed induction generator connected to the grid. The objective of the separate control of active and reactive stator powers is to provide constant power to the power grid whatever the variation of the wind speed, and to provide reactive power to correct the power factor. In this article, we present the modeling and an integrated vector control in a double-fed induction generator wind chain, which aims to independently control the active and reactive power generated by the double-fed induction generator. Knowing that the direct control of active and reactive power delivered to the grid with conventional proportional integral controllers provides good performance in permanent diet but a variable speed wind, the measured powers hardly follow the set values. To remedy this problem, we replace the conventional proportional integral controllers with proportional integral–fuzzy controllers to ensure good performance and robustness of the control of separate powers. To justify this choice, it is necessary to evaluate and compare the separate control loop for active and reactive power with conventional proportional integral controllers than with proportional integral–fuzzy controllers under the same constraint variable speed wind. The second part treated in this article is to reduce the harmonic pollution caused by the supply of the double-fed induction generator–based inverters and controlled rectifiers, which strongly infect current line. This phenomenon can have an adverse effect on the loads connected to the grid and equipment of proximity. The insertion of a filter system in the chain is needed, except that the strain of the volume and the reflection require a high cost for a more advanced and more optimal solution. Our contribution to this part is to replace the supply of the double-fed induction generator rotor side by a matrix converter controlled by the modulation technique of the difference errors between the measured values and the desired output values (least mean square errors).
23 October 2021 in International Journal of Robotics and Control Systems
The detection of faults in a wind turbine chain is of prime importance in order to maintain safety, enhance reliability and improve economic performance. In addition, wind systems have to ensure a continuity of service for a considerable period of time in the event of an electrical fault in the network or a fault in one of the elements of the electromechanical conversion system. This paper presents a fault detection methodology of the power converter within a wind turbine chain, equipped with a Doubly-Fed Induction Generator (DFIG). A configurable, fast, and accurate scheme is developed, the basis of which is the reliable identification of the failed switch. The solution proposed in this work involves the deployment of a redundant arm in the event of a fault; the replacement arm is utilized while waiting for a maintenance or repair operation to be carried out. The approach developed in this paper provides continuity of service after the occurrence of a fault in the network system and fault detection time is reduced. The validity of the proposed identification methodology is assessed by means of simulation of the model of a wind turbine conversion system.
The doubly fed induction generator (DFIG) has become one of the most widely adopted technologies in modern wind energy conversion systems due to its high efficiency, flexible operation, and capability to operate under variable wind-speed conditions. Nevertheless, maintaining high power quality, reducing harmonic distortion, and ensuring reliable operation under parameter uncertainties and grid disturbances remain major challenges. Conventional proportional–integral (PI)-based control approaches often suffer from limited robustness and sensitivity to system nonlinearities, which can adversely affect the dynamic performance and operational stability of wind energy systems. To address these limitations, this paper proposes an advanced hybrid control strategy based on the integration of fuzzy logic (FL) and a third-order sliding mode controller (TOSMC) for the control of DFIG-based wind turbines. The proposed FL–TOSMC combines the robustness and fast convergence properties of sliding mode control with the adaptive capability of fuzzy logic, thereby reducing dependence on accurate mathematical models and enhancing tolerance to parameter variations and external disturbances. The developed controller is applied to maximum power point tracking (MPPT) and direct field-oriented control of the DFIG to maximize energy extraction and ensure stable power regulation. The simulation results obtained in the MATLAB/Simulink (2021) environment demonstrate that the proposed strategy improves the dynamic response of the system by reducing overshoot, accelerating error convergence, minimizing steady-state oscillations, and decreasing total harmonic distortion compared with the conventional TOSMC approach. Furthermore, the proposed controller provides enhanced tracking performance, improved robustness against parameter uncertainties, and better power-quality characteristics under various operating conditions. These results indicate that the FL–TOSMC approach is an effective control solution for improving the operational performance of DFIG-based wind energy conversion systems.
The paper deals with the multilevel converters control strategy for photovoltaic system integrated in distribution grids. The objective of the proposed work is to design multilevel inverters for solar energy applications so as to reduce the Total Harmonic Distortion (THD) and to improve the power quality. The multilevel inverter power structure plays a vital role in every aspect of the power system. It is easier to produce a high-power, high-voltage inverter with the multilevel structure. The topologies of multilevel inverter have several advantages such as high output voltage, lower total harmonic distortion (THD) and reduction of voltage ratings of the power semiconductor switching devices. The proposed control strategy ensures an implementation of selective harmonic elimination (SHE) modulation for eleven levels. SHE is a very important and efficient strategy of eliminating selected harmonics by judicious selection of the firing angles of the inverter. Harmonics elimination technique eliminates the need of the expensive low pass filters in the system. Previous research considered that constant and equal DC sources with invariant behavior; however, this research extends earlier work to include variant DC sources, which are typical of lead-acid batteries when used in system PV. This Study also investigates methods to minimize the total harmonic distortion of the synthesized multilevel waveform and to help balance the battery voltage. The harmonic elimination method was used to eliminate selected lower dominant harmonics resulting from the inverter switching action.
Renewable resources are increasingly acknowledged as a crucial solution to address escalating energy demands and combat heightened greenhouse gas emissions within conventional energy systems. This research delves into the techno-economic feasibility of incorporating fuel cell systems into stand-alone hybrid systems tailored to electrify a community load situated in Annaba, northeastern Algeria. This load averages 6.9 kW of power and requires 165.59 kWh/day annually. Employing HOMER software, a comprehensive comparative analysis of four distinct hybrid power system configurations—namely PV/BAT, PV/BAT/DG, PV/BAT/FC, and PV/BAT/FC/DG—was conducted to pinpoint the most optimal solution in meeting energy demands. Parameters such as net present cost, energy cost, energy surplus, load satisfaction, and CO2 emissions were considered. Additionally, the study addressed the environmental impact and evaluated the impact of varying storage battery fleet sizes on the total cost of the power system. Among the configurations scrutinized, the PV/BAT/FC/DG hybrid system emerged as the most favorable option, striking a well-balanced compromise between PV penetration efficiency, energy cost, and system stability. Moreover, the findings highlight the benefits of integrating fuel cell technology into the hybrid system, including minimizing excess energy, reducing the necessity for DG interventions, and optimizing the size of the battery bank.