30 August 2013 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
HHHans Holten-Lund
Hans Holten-Lund
RNRonnie Thorup Nilsson
Ronnie Thorup Nilsson
MHMartin Hansen
Martin Hansen
ULUlrik Darling Larsen
Ulrik Darling Larsen
MRMorten Fischer Rasmussen
Morten Fischer Rasmussen
The Synthetic Aperture Real-time Ultrasound System (SARUS) for acquiring and processing synthetic aperture (SA) data for research purposes is described. The specifications and design of the system are detailed, along with its performance for SA, nonlinear, and 3-D flow estimation imaging. SARUS acquires individual channel data simultaneously for up to 1024 transducer elements for a couple of heart beats, and is capable of transmitting any kind of excitation. The 64 boards in the system house 16 transmit and 16 receive channels each, where sampled channel data can be stored in 2 GB of RAM and processed using five field-programmable gate arrays (FPGAs). The fully parametric focusing unit calculates delays and apodization values in real time in 3-D space and can produce 350 million complex samples per channel per second for full non-recursive synthetic aperture B-mode imaging at roughly 30 high-resolution images/s. Both RF element data and beamformed data can be stored in the system for later storage and processing. The stored data can be transferred in parallel using the system's sixty-four 1-Gbit Ethernet interfaces at a theoretical rate of 3.2 GB/s to a 144-core Linux cluster.

23 February 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
KBKevin Brenner
Kevin Brenner
AEArif Sanli Ergun
Arif Sanli Ergun
KFKamyar Firouzi
Kamyar Firouzi
MRMorten Fischer Rasmussen
Morten Fischer Rasmussen
QSQuintin Stedman
Quintin Stedman
BKButrus T. Khuri-Yakub
Butrus T. Khuri-Yakub
Capacitive micromachined ultrasonic transducer (CMUT) technology has enjoyed rapid development in the last decade. Advancements both in fabrication and integration, coupled with improved modelling, has enabled CMUTs to make their way into mainstream ultrasound imaging systems and find commercial success. In this review paper, we touch upon recent advancements in CMUT technology at all levels of abstraction; modeling, fabrication, integration, and applications. Regarding applications, we discuss future trends for CMUTs and their impact within the broad field of biomedical imaging.

28 August 2019 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
SKSri-Rajasekhar Kothapalli
Sri-Rajasekhar Kothapalli
GSGeoffrey Alexander Sonn
Geoffrey Alexander Sonn
JCJung Woo Choe
Jung Woo Choe
ANAmin Nikoozadeh
Amin Nikoozadeh
ABAnshuman Bhuyan
Anshuman Bhuyan
SGSanjiv S. Gambhir
Sanjiv S. Gambhir
Transrectal ultrasound and photoacoustic imaging simultaneously provide structural and molecular contrasts of normal and cancerous human prostates.

26 September 2014 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MPMichael Johannes Pihl
Michael Johannes Pihl
MSMatthias Bo Stuart
Matthias Bo Stuart
BTBorislav Gueorguiev Tomov
Borislav Gueorguiev Tomov
MRMorten Fischer Rasmussen
Morten Fischer Rasmussen
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
The 3-D transverse oscillation method is investigated by estimating 3-D velocities in an experimental flow-rig system. Measurements of the synthesized transverse oscillating fields are presented as well. The method employs a 2-D transducer; decouples the velocity estimation; and estimates the axial, transverse, and elevation velocity components simultaneously. Data are acquired using a research ultrasound scanner. The velocity measurements are conducted with steady flow in sixteen different directions. For a specific flow direction with [α, β] = [45, 15]°, the mean estimated velocity vector at the center of the vessel is (v x , v y , v z ) = (33.8, 34.5, 15.2) ± (4.6, 5.0, 0.6) cm/s where the expected velocity is (34.2, 34.2, 13.0) cm/s. The velocity magnitude is 50.6 ± 5.2 cm/s with a bias of 0.7 cm/s. The flow angles α and β are estimated as 45.6 ± 4.9° and 17.6 ± 1.0°. Subsequently, the precision and accuracy are calculated over the entire velocity profiles. On average for all direction, the relative mean bias of the velocity magnitude is -0.08%. For α and β, the mean bias is -0.2° and -1.5°. The relative standard deviations of the velocity magnitude ranges from 8 to 16%. For the flow angles, the ranges of the mean angular deviations are 5° to 16° and 0.7° and 8°.

1 July 2013
Verified
Conference Paper
Closed access
MRMorten Fischer Rasmussen
Morten Fischer Rasmussen
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
A real-time 3-D ultrasound measurement using only 32 elements and 32 emissions is presented. The imaging quality is compared to a conventionally fully addressed array using 1024 elements and 256 emissions. The main-lobe of the measured line spread function is almost identical, but the side-lobe levels are higher for the row-column addressed array. The cystic resolution sampled at a relative intensity difference of 20 dB shows a cyst size of 5.00mm for the row-column addressed array and 2.39mm for the fully sampled array. A simulation study is carried out which compares how the imaging quality of the two addressing methods scales with the number of beamforming channels used. It is shown that for any fixed number of active elements, a row-column addressed array achieves a better image quality than fully addressing the array. When using 128 channels, the main-lobe when fully addressing the array is 510% larger than when row-column addressing the array. The cyst radius needed to achieve -20 dB intensity in the cyst is 396% larger for the fully addressed array compared to the row-column addressed array. The measurements were made using the experimental ultrasound scanner SARUS and a 32×32 element ultrasound probe made by Vermon S.A.

26 September 2014 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MRMorten Fischer Rasmussen
Morten Fischer Rasmussen
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
This paper demonstrates that synthetic aperture imaging (SAI) can be used to achieve real-time 3-D ultrasound phased-array imaging. It investigates whether SAI increases the image quality compared with the parallel beamforming (PB) technique for real-time 3-D imaging. Data are obtained using both simulations and measurements with an ultrasound research scanner and a commercially available 3.5- MHz 1024-element 2-D transducer array. To limit the probe cable thickness, 256 active elements are used in transmit and receive for both techniques. The two imaging techniques were designed for cardiac imaging, which requires sequences designed for imaging down to 15 cm of depth and a frame rate of at least 20 Hz. The imaging quality of the two techniques is investigated through simulations as a function of depth and angle. SAI improved the full-width at half-maximum (FWHM) at low steering angles by 35%, and the 20-dB cystic resolution by up to 62%. The FWHM of the measured line spread function (LSF) at 80 mm depth showed a difference of 20% in favor of SAI. SAI reduced the cyst radius at 60 mm depth by 39% in measurements. SAI improved the contrast-to-noise ratio measured on anechoic cysts embedded in a tissue-mimicking material by 29% at 70 mm depth. The estimated penetration depth on the same tissue-mimicking phantom shows that SAI increased the penetration by 24% compared with PB. Neither SAI nor PB achieved the design goal of 15 cm penetration depth. This is likely due to the limited transducer surface area and a low SNR of the experimental scanner used.