Sri-Rajasekhar Kothapalli

Dr. Sri-Rajasekhar Kothapalli

Pennsylvania State University, University Park, United States
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 August 2019 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
SKSri-Rajasekhar Kothapalli
Sri-Rajasekhar Kothapalli
GSGeoffrey Alexander Sonn
Geoffrey Alexander Sonn
JCJung Woo Choe
Jung Woo Choe
ANAmin Nikoozadeh
Amin Nikoozadeh
ABAnshuman Bhuyan
Anshuman Bhuyan
SGSanjiv S. Gambhir
Sanjiv S. Gambhir
Transrectal ultrasound and photoacoustic imaging simultaneously provide structural and molecular contrasts of normal and cancerous human prostates.

28 November 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
ADAjay Dangi
Ajay Dangi
CCChristopher Cheng
Christopher Cheng
SASumit Agrawal
Sumit Agrawal
STSudhanshu Tiwari
Sudhanshu Tiwari
GDGaurav Ramesh Datta
Gaurav Ramesh Datta
SKSri-Rajasekhar Kothapalli
Sri-Rajasekhar Kothapalli
A linear piezoelectric micromachined ultrasound transducer (PMUT) array was fabricated and integrated into a device for photoacoustic imaging (PAI) of tissue phantoms. The PMUT contained 65 array elements, with each element having 60 diaphragms of 60 μm diameter and 75 μm pitch. A lead zirconate titanate (PZT) thin film was used as the piezoelectric layer. The in-air vibration response of the PMUT array elements showed a first mode resonance between 6 and 8 MHz. Hydrophone measurements showed 16.2 kPa average peak ultrasound pressure output at 7.5 mm from one element excited with 5 Vpp input. A receive sensitivity of ~0.48 mV/kPa was observed for a PMUT array element with 0 dB gain. The PMUT array was bonded to a custom-printed circuit board to enable compact integration with an optical fiber bundle for PAI. A broad photoacoustic bandwidth of ~89% was observed for the photoacoustic response captured from absorbing pencil lead targets. Linear scanning of a single element of a PMUT array was performed on different tissue phantoms embedded with light-absorbing targets to successfully demonstrate B-mode PAI using PMUTs.

29 October 2019 in Optics Letters
Verified
Journal Article
Closed access
PDF file
ADAjay Dangi
Ajay Dangi
SASumit Agrawal
Sumit Agrawal
SKSri-Rajasekhar Kothapalli
Sri-Rajasekhar Kothapalli
This Letter demonstrates lithium niobate (LiNbO3)-based transparent ultrasound transducers (TUTs) for photoacoustic imaging applications. The TUTs were fabricated by coating the top and bottom surfaces of a 0.25 mm thick LiNbO3wafer with transparent indium-tin-oxide (ITO) electrodes. The resulting transducers showed ∼80% optical transparency in the wavelength range of 690–970 nm. The TUTs had a resonant frequency of 14.5 MHz and ∼70% photoacoustic bandwidth. The versatility of the TUT approach is demonstrated by introducing two different transparent photoacoustic imaging (PAI) geometries. In one method, which suits endoscopy applications, an optical fiber of a laser diode is directly fixed on the backside of a 2.5 mm diameter TUT, and the fiber-TUT device is raster scanned to form 3D photoacoustic images. In the second method, which suits high-throughput applications, a free-space optical-only raster scanning of the laser fiber across a 1  cm×1  cm planar TUT yielded 3D photoacoustic images. The proposed TUT approach is low in cost, easy to manufacture, compatible with conventional clinical ultrasound electronics, and scalable for different configurations, including 2D TUT arrays to achieve real-time 3D high-throughput PAI.

9 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SASumit Agrawal
Sumit Agrawal
Mithun Kuniyil Ajith SinghMithun Kuniyil Ajith Singh
Mithun Kuniyil Ajith Singh
KJKerrick Johnstonbaugh
Kerrick Johnstonbaugh
DHDavid C. Han
David C. Han
CPColette R. Pameijer
Colette R. Pameijer
SKSri-Rajasekhar Kothapalli
Sri-Rajasekhar Kothapalli
Vascular diseases are becoming an epidemic with an increasing aging population and increases in obesity and type II diabetes. Point-of-care (POC) diagnosis and monitoring of vascular diseases is an unmet medical need. Photoacoustic imaging (PAI) provides label-free multiparametric information of deep vasculature based on strong absorption of light photons by hemoglobin molecules. However, conventional PAI systems use bulky nanosecond lasers which hinders POC applications. Recently, light-emitting diodes (LEDs) have emerged as cost-effective and portable optical sources for the PAI of living subjects. However, state-of-art LED arrays carry significantly lower optical energy (<0.5 mJ/pulse) and high pulse repetition frequencies (PRFs) (4 KHz) compared to the high-power laser sources (100 mJ/pulse) with low PRFs of 10 Hz. Given these tradeoffs between portability, cost, optical energy and frame rate, this work systematically studies the deep tissue PAI performance of LED and laser illuminations to help select a suitable source for a given biomedical application. To draw a fair comparison, we developed a fiberoptic array that delivers laser illumination similar to the LED array and uses the same ultrasound transducer and data acquisition platform for PAI with these two illuminations. Several controlled studies on tissue phantoms demonstrated that portable LED arrays with high frame averaging show higher signal-to-noise ratios (SNRs) of up to 30 mm depth, and the high-energy laser source was found to be more effective for imaging depths greater than 30 mm at similar frame rates. Label-free in vivo imaging of human hand vasculature studies further confirmed that the vascular contrast from LED-PAI is similar to laser-PAI for up to 2 cm depths. Therefore, LED-PAI systems have strong potential to be a mobile health care technology for diagnosing vascular diseases such as peripheral arterial disease and stroke in POC and resource poor settings.

11 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
HCHaoyang Chen
Haoyang Chen
SASumit Agrawal
Sumit Agrawal
ADAjay Dangi
Ajay Dangi
CWChristopher Wible
Christopher Wible
MOMohamed Osman
Mohamed Osman
SKSri-Rajasekhar Kothapalli
Sri-Rajasekhar Kothapalli
The opacity of conventional ultrasound transducers can impede the miniaturization and workflow of current photoacoustic systems. In particular, optical-resolution photoacoustic microscopy (OR-PAM) requires the coaxial alignment of optical illumination and acoustic-detection paths through complex beam combiners and a thick coupling medium. To overcome these hurdles, we developed a novel OR-PAM method on the basis of our recently reported transparent lithium niobate (LiNbO3) ultrasound transducer (Dangi et al., Optics Letters, 2019), which was centered at 13 MHz ultrasound frequency with 60% photoacoustic bandwidth. To test the feasibility of wearable OR-PAM, optical-only raster scanning of focused light through a transducer was performed while the transducer was fixed above the imaging subject. Imaging experiments on resolution targets and carbon fibers demonstrated a lateral resolution of 8.5 µm. Further, we demonstrated vasculature mapping using chicken embryos and melanoma depth profiling using tissue phantoms. In conclusion, the proposed OR-PAM system using a low-cost transparent LiNbO3 window transducer has a promising future in wearable and high-throughput imaging applications, e.g., integration with conventional optical microscopy to enable a multimodal microscopy platform capable of ultrasound stimulation.

15 September 2021 in Photoacoustics
Verified
Journal Article
Open access
SASumit Agrawal
Sumit Agrawal
TSThaarakh Suresh
Thaarakh Suresh
AGAnkit Garikipati
Ankit Garikipati
ADAjay Dangi
Ajay Dangi
SKSri-Rajasekhar Kothapalli
Sri-Rajasekhar Kothapalli
Combined ultrasound and photoacoustic (USPA) imaging has attracted several pre-clinical and clinical applications due to its ability to simultaneously display structural, functional, and molecular information of deep biological tissue in real time. However, the depth and wavelength dependent optical attenuation and the unknown optical and acoustic heterogeneities limit the USPA imaging performance in deep tissue regions. Novel instrumentation, image reconstruction, and artificial intelligence (AI) methods are currently being investigated to overcome these limitations and improve the USPA image quality. Effective implementation of these approaches requires a reliable USPA simulation tool capable of generating US based anatomical and PA based molecular contrasts of deep biological tissue. Here, we developed a hybrid USPA simulation platform by integrating finite element models of light (NIRFast) and ultrasound (k-Wave) propagations for co-simulation of B-mode US and PA images. The platform allows optimization of different design parameters for USPA devices, such as the aperture size and frequency of both light and ultrasound detector arrays. For designing tissue-realistic digital phantoms, a dictionary-based function has been added to k-Wave to generate various levels of ultrasound speckle contrast. The feasibility of modeling US imaging combined with optical fluence dependent multispectral PA imaging is demonstrated using homogeneous as well as heterogeneous tissue phantoms mimicking human organs (e.g., prostate and finger). In addition, we also demonstrate the potential of the simulation platform to generate large scale application-specific training and test datasets for AI enhanced USPA imaging. The complete USPA simulation codes together with the supplementary user guides have been posted to an open-source repository (https://github.com/KothapalliLabPSU/US-PA_simulation_codes).