Smart campus microgrids are considered in this paper, with the aim of highlighting their applicability in the framework of the sustainable energy transition. In particular, the campus of the Hellenic Mediterranean University (HMU) in Heraklion, Crete, Greece, is selected as a case study to highlight the multiple campus microgrids’ advantages. Crete represents an interesting insular power system case, due to the high renewable energy sources capacity and the large summer tourism industry. There is also a high density of university and research campuses, making the campus microgrid concept a promising solution for the energy transition and decarbonization of the island. In this sense, policy directions that could facilitate the development of the smart campus microgrid are also given, to motivate areas with similar characteristics. For the performed case study, the HMU microgrid is assumed to consist of PV systems, wind turbines, battery energy storage systems and EV chargers. The analysis explores the financial feasibility and environmental impact of such an investment through the optimal sizing of the systems under investigation, while a sensitivity analysis regarding the battery system cost is also performed. Apart from the financial benefits of the investment, it is evident that the main grid experiences a significant load reduction, with the microgrid acting as a RES producer for many hours, hence improving system adequacy. Moreover, it is shown that the location of HMU makes the investment more sustainable compared to other locations in northern Europe, such as Stockholm and London. The methodology and the derived results are expected to motivate such investments, especially in areas with high RES capacity and a high density of university and research campuses.
25 December 2019 in IEEE Transactions on Control Systems Technology
Droop-controlled inverters are widely used to integrate distributed energy resources (DERs) to the smart grid and provide ancillary services (frequency and voltage support). However, during grid variations or faults, the droop control scheme should inherit a current-limiting property to protect both the inverter and the DER unit. In this brief, a novel structure of the recently developed current-limiting droop (CLD) controller is proposed to accomplish two main tasks: 1) guarantee current limitation with maximum power injection during grid faults and 2) rigorously guarantee asymptotic stability of any equilibrium point in a given bounded operating range of the closed-loop system for a grid-connected inverter. Since the maximum power of the DER unit can be utilized under grid faults with the proposed enhanced CLD and then inspired by the latest fault-ride-through requirements, it is further extended to provide voltage support to a faulty grid via the maximum injection of reactive power. This is achieved by simply adjusting the reactive power reference opposed to the existing control schemes that require adjustment of both the real and the reactive powers. Hence, a unified current-limiting control scheme for grid-connected inverters under both normal and faulty grids with a simplified voltage support mechanism is developed and experimentally verified in this brief.
Power hardware-in-the-loop (PHIL) simulation leverages the advanced real-time emulation based technique to carry out in-depth investigations on novel real-world power components. Power amplifiers, sensors, and signal conversion units based power interfaces (PI) incorporate physical hardware systems and real-time simulation platforms into PHIL setups. However, the employment of any interfacing technique inevitably introduces disturbances such as sensor noise, switching harmonics, or quantization noise to PHIL systems. To facilitate quantitatively analyzing and assessing the impact of external disturbances on PHIL simulation systems, a framework for sensitivity analysis of PHIL setups has been developed in this paper. Detailed modelling principles related to the sensitivity analysis of PHIL systems and the inherent relationship between sensitivity transfer functions and stability criteria are elaborated along with theoretical and experimental validation. Based on this concept, accuracy assessment methods are employed in this framework to quantify generic sensitivity criteria. Moreover, physical passive load and converter-based PHIL setups are applied and experimental results are presented to characterize and demonstrate the applicability of the proposed framework.
24 February 2023 in Electric Power Systems Research
Geographically distributed simulations (GDS) overcome the inherent limitations in capabilities of single research infrastructure to accurately represent large-scale complex power and energy systems within representative operating environments in real-time. The feasibility of GDS has been proven, however, there is a lack of confidence in its adoption owing to limited evidence of its stability and accuracy that ascertain its practical applicability. This paper presents detailed small signal stability models for GDS setups with two interface signals transformations. The models have been validated by empirical analysis and used for determining the boundaries for stable operation of GDS setups. For the common region of stability of the two transformations considered, accuracy analysis presented offers insights for their selection. This advancement, thereby, enables realisation of experimental setups that can cater for the growing need to design and validate operational schemes that ensure robust and resilient operation of critical national infrastructure.