Sophia Sakellariou

Sophia Sakellariou


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2009
Verified
Book Chapter
Closed access
PDF file
SSSophia Sakellariou
Sophia Sakellariou
BWBen M. Ward
Ben M. Ward
Vassilis CharissisVassilis Charissis
Vassilis Charissis
DCDavid Chanock
David Chanock
PAPaul Anderson
Paul Anderson

8 October 2016 in Medical Engineering & Physics
Verified
Journal Article
Closed access
SSSophia Sakellariou
Sophia Sakellariou
WLWenguang Li
Wenguang Li
Manosh PaulManosh Paul
Manosh Paul
GRGiles Roditi
Giles Roditi
Iodinated contrast media (CM) are the most commonly used injectables in radiology today. A range of different media are commercially available, combining various physical and chemical characteristics (ionic state, osmolality, viscosity) and thus exhibiting distinct in vivo behaviour and safety profiles. In this paper, numerical simulations of blood flow with contrast media were conducted to investigate the effects of contrast viscosity on generated vessel wall shear stress and vessel wall pressure to elucidate any possible relation to extravasations. Five different types of contrast for Iodine fluxes ranging at 1.5-2.2gI/s were modelled through 18G and 20G cannulae placed in an ideal vein at two different orientation angles. Results demonstrate that the least viscous contrast media generate the least maximum wall shear stress as well as the lowest total pressure for the same flow rate. This supports the empirical clinical observations and hypothesis that more viscous contrast media are responsible for a higher percentage of contrast extravasations. In addition, results support the clinical hypothesis that a catheter tip directed obliquely to the vein wall always produces the highest maximum wall shear stress and total pressure due to impingement of the contrast jet on the vessel wall.

1 May 2022 in British Journal of Radiology
Verified
Journal Article
Closed access
FCFotios Constantinidis
Fotios Constantinidis
SSSophia Sakellariou
Sophia Sakellariou
SCSau Lee Chang
Sau Lee Chang
SLSvetlana Linder
Svetlana Linder
BMBarbara MacPherson
Barbara MacPherson
ASArchana Seth
Archana Seth
Objectives: The purpose of this article is to review the technical and radiological aspects of MagSeed® localisation, to assess its accuracy based on post-localisation mammograms and excision specimen X-rays and to discuss the radiological experience of our institutions. Methods: Two-year data were collected retrospectively from three NHS boards from the West of Scotland. A total of 309 MagSeeds® were inserted under mammographic or ultrasonographic guidance in 300 women with unifocal, multifocal and/or bilateral breast lesions at the day of surgery or up to 30 days prior to it. Radiological review of post-localisation mammograms and intraoperative specimen X-rays as well as a review of the surgical outcomes were performed to assess the accuracy and efficacy of the method. Our experience relating to the technique’s strengths and downsides were also noted. Results: The MagSeeds® were inserted on average 7.2 days before surgery. The localisation technique was straight forward for the radiologists. In 99% of the cases, the MagSeed® was successfully deployed and 100% of the successfully localised lesions were excised at surgery. There was no difference in the accuracy of the localisation whether this was mammographically or ultrasonographically guided. On post-localisation mammograms, the MagSeed® was radiologically accurately positioned in 97.3% of the cases. No delayed MagSeed® migration was observed. On the specimen X-rays, the lesion was centrally positioned in 45.1%, eccentric within more than 1 mm from the margin in 35.7% and in 14.8% it was at the specimen’s margin. The re-excision rate was 18.3%. Conclusion: The MagSeed® is an accurate and reliable localisation method in breast conserving surgery with good surgical outcomes. Advances in knowledge: To our knowledge, the radiological aspects of MagSeed® localisation have not been widely described in peer-reviewed journals thus far.

1 January 2011
Verified
Book Chapter
Closed access
PDF file
SSSophia Sakellariou
Sophia Sakellariou
Vassilis CharissisVassilis Charissis
Vassilis Charissis
SGStephen Grant
Stephen Grant
JTJanice Turner
Janice Turner
DKDianne Kelly
Dianne Kelly
CCChistodoulos Christomanos
Chistodoulos Christomanos

Verified
Journal Article
Open access
PDF file
SKSoheeb Khan
Soheeb Khan
Vassilis CharissisVassilis Charissis
Vassilis Charissis
SSSophia Sakellariou
Sophia Sakellariou
The hip joint is highly prone to traumatic and degenerative pathologies resulting in irregular locomotion. Monitoring and treatment depend on high-end technology facilities requiring physician and patient co-location, thus limiting access to specialist monitoring and treatment for populations living in rural and remote locations. Telemedicine offers an alternative means of monitoring, negating the need for patient physical presence. In addition, emerging technologies, such as virtual reality (VR) and immersive technologies, offer potential future solutions through virtual presence, where the patient and health professional can meet in a virtual environment (a virtual clinic). To this end, a prototype asynchronous telemedicine VR gait analysis system was designed, aiming to transfer a full clinical facility within the patients’ local proximity. The proposed system employs cost-effective alternative motion capture combined with the system’s immersive 3D virtual gait analysis clinic. The user interface and the tools in the application offer health professionals asynchronous, objective, and subjective analyses. This paper investigates the requirements for the design of such a system and discusses preliminary comparative data of its performance evaluation against a high-fidelity gait analysis clinical application.

1 January 2014
Verified
Conference Paper
Closed access
MKM.S. Khan
M.S. Khan
WCW. Chan
W. Chan
Vassilis CharissisVassilis Charissis
Vassilis Charissis
DHD.K. Harrison
D.K. Harrison
SSSophia Sakellariou
Sophia Sakellariou