Ahmed Alsadig Ahmed

Mr. Ahmed Alsadig Ahmed

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2023 in Talanta
Verified
Journal Article
Closed access
GSgiulia siciliano
giulia siciliano
AAAhmed Alsadig Ahmed
Ahmed Alsadig Ahmed
MCMaria Serena Chiriacò
Maria Serena Chiriacò
ATAntonio Turco
Antonio Turco
AFAlessia Foscarini
Alessia Foscarini
EPElisabetta Primiceri
Elisabetta Primiceri

14 April 2023 in Molecules
Verified
Journal Article
Open access
PDF file
AAAbdullahi Abbas Adam
Abdullahi Abbas Adam
HSHassan Soleimani
Hassan Soleimani
John Ojur DennisJohn Ojur Dennis
John Ojur Dennis
Osamah AldaghriOsamah Aldaghri
Osamah Aldaghri
AAAhmed Alsadig Ahmed
Ahmed Alsadig Ahmed
MSM.F. Shukur
M.F. Shukur
The increased interest in the transition from liquid to solid polymer electrolytes (SPEs) has driven enormous research in the area polymer electrolyte technology. Solid biopolymer electrolytes (SBEs) are a special class of SPEs that are obtained from natural polymers. Recently, SBEs have been generating much attention because they are simple, inexpensive, and environmentally friendly. In this work, SBEs based on glycerol-plasticized methylcellulose/pectin/potassium phosphate (MC/PC/K3PO4) are investigated for their potential application in an electrochemical double-layer capacitor (EDLC). The structural, electrical, thermal, dielectric, and energy moduli of the SBEs were analyzed via X-ray diffractometry (XRD), Fourier transforms infrared spectroscopy (FTIR), electrochemical impedance spectroscopy (EIS), transference number measurement (TNM), and linear sweep voltammetry (LSV). The plasticizing effect of glycerol in the MC/PC/K3PO4/glycerol system was confirmed by the change in the intensity of the samples’ FTIR absorption bands. The broadening of the XRD peaks demonstrates that the amorphous component of SBEs increases with increasing glycerol concentration, while EIS plots demonstrate an increase in ionic conductivity with increasing plasticizer content owing to the formation of charge-transfer complexes and the expansion of amorphous domains in polymer electrolytes (PEs). The sample containing 50% glycerol has a maximal ionic conductivity of about 7.5 × 10−4 scm−1, a broad potential window of 3.99 V, and a cation transference number of 0.959 at room temperature. Using the cyclic voltammetry (CV) test, the EDLC constructed from the sample with the highest conductivity revealed a capacitive characteristic. At 5 mVs−1, a leaf-shaped profile with a specific capacitance of 57.14 Fg−1 was measured based on the CV data.

21 November 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
FUFahad Usman
Fahad Usman
John Ojur DennisJohn Ojur Dennis
John Ojur Dennis
AAA.I. Aljameel
A.I. Aljameel
MAM.K.M. Ali
M.K.M. Ali
Osamah AldaghriOsamah Aldaghri
Osamah Aldaghri
fabrice meriaudeaufabrice meriaudeau
fabrice meriaudeau
Lung cancer is the most common and deadliest cancer type globally. Its early diagnosis can guarantee a five-year survival rate. Unfortunately, application of the available diagnosis methods such as computed tomography, chest radiograph, magnetic resonance imaging (MRI), ultrasound, low-dose CT scan, bone scans, positron emission tomography (PET), and biopsy is hindered due to one or more problems, such as phenotypic properties of tumours that prevent early detection, invasiveness, expensiveness, and time consumption. Detection of lung cancer biomarkers using a biosensor is reported to solve the problems. Among biosensors, optical biosensors attract greater attention due to being ultra-sensitive, free from electromagnetic interference, capable of wide dynamic range detection, free from the requirement of a reference electrode, free from electrical hazards, highly stable, capable of multiplexing detection, and having the potential for more information content than electrical transducers. Inspired by promising features of plasmonic sensors, including surface plasmon resonance (SPR), localised surface plasmon resonance (LSPR), and surface enhanced Raman scattering (SERS) such as ultra-sensitivity, single particle/molecular level detection capability, multiplexing capability, photostability, real-time measurement, label-free measurement, room temperature operation, naked-eye readability, and the ease of miniaturisation without sophisticated sensor chip fabrication and instrumentation, numerous plasmonic sensors for the detection of lung cancer biomarkers have been investigated. In this review, the principle plasmonic sensor is explained. In addition, novel strategies and modifications adopted for the detection of lung cancer biomarkers such as miRNA, carcinoembryonic antigen (CEA), cytokeratins, and volatile organic compounds (VOCs) using plasmonic sensors are also reported. Furthermore, the challenges and prospects of the plasmonic biosensors for the detection of lung cancer biomarkers are highlighted.

12 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
SDSani Nazifi Dalhatu
Sani Nazifi Dalhatu
KMKolo Alhaji Modu
Kolo Alhaji Modu
Auwal Adamu MahmoudAuwal Adamu Mahmoud
Auwal Adamu Mahmoud
Zakariyya Uba Uba ZangoZakariyya Uba Uba Zango
Zakariyya Uba Uba Zango
AUAbdullahi Bello Umar
Abdullahi Bello Umar
Osamah AldaghriOsamah Aldaghri
Osamah Aldaghri
Corrosion prevention has been a global phenomenon, particularly in metallic and construction engineering. Most inhibitors are expensive and toxic. Therefore, developing nontoxic and cheap corrosion inhibitors has been a way forward. In this work, L-arginine was successfully grafted on chitosan by the thermal technique using a reflux condenser. This copolymer was characterized by Fourier-transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), and X-ray diffraction (XRD). The corrosion inhibition performance of the composite polymer was tested on mild steel in 0.5M HCl by electrochemical methods. The potentiodynamic polarization (PDP) and electrochemical impedance spectroscopy (EIS) results were consistent. The inhibition efficiency at optimum concentration rose to 91.4%. The quantum chemical calculation parameters show good properties of the material as a corrosion inhibitor. The molecular structure of the inhibitor was subjected to density functional theory (DFT) to understand its theoretical properties, and the results confirmed the inhibition efficiency of the grafted polymer for corrosion prevention.

15 January 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
AAAnas A. M. Alqanoo
Anas A. M. Alqanoo
Naser AhmedNaser Ahmed
Naser Ahmed
MHMd Roslan Hashim
Md Roslan Hashim
MAMunirah A. Almessiere
Munirah A. Almessiere
STSofyan A. Taya
Sofyan A. Taya
KIKhalid Ibnaouf
Khalid Ibnaouf
The applications of silver nanowires (AgNWs) are clearly relevant to their purity and morphology. Therefore, the synthesis parameters should be precisely adjusted in order to obtain AgNWs with a high aspect ratio. Consequently, controlling the reaction time versus the reaction temperature of the AgNWs is crucial to synthesize AgNWs with a high crystallinity and is important in fabricating optoelectronic devices. In this work, we tracked the morphological alterations of AgNWs during the growth process in order to determine the optimal reaction time and temperature. Thus, here, the UV–Vis absorption spectra were used to investigate how the reaction time varies with the temperature. The reaction was conducted at five different temperatures, 140–180 °C. As a result, an equation was developed to describe the relationship between them and to calculate the reaction time at any given reaction temperature. It was observed that the average diameter of the NWs was temperature-dependent and had a minimum value of 23 nm at a reaction temperature of 150 °C. A significant purification technique was conducted for the final product at a reaction temperature of 150 °C with two different speeds in the centrifuge to remove the heavy and light by-products. Based on these qualities, a AgNWs-based porous Si (AgNWs/P-Si) device was fabricated, and current-time pulsing was achieved using an ultra-violet (UV) irradiation of a 375 nm wavelength at four bias voltages of 1 V, 2 V, 3 V, and 4 V. We obtained a high level of sensitivity and detectivity with the values of 2247.49% and 2.89 × 1012 Jones, respectively. The photocurrent increased from the μA range in the P-Si to the mA range in the AgNWs/P-Si photodetector due to the featured surface plasmon resonance of the AgNWs compared to the other metals.

6 February 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
FUFahad Usman
Fahad Usman
KGKamarul Hawari Ghazali
Kamarul Hawari Ghazali
RMRazali Muda
Razali Muda
John Ojur DennisJohn Ojur Dennis
John Ojur Dennis
KIKhalid Ibnaouf
Khalid Ibnaouf
Rajan JoseRajan Jose
Rajan Jose
Kidney-related health problems cause millions of deaths around the world annually. Fortunately, most kidney problems are curable if detected at the earliest stage. Continuous monitoring of ammonia from exhaled breath is considered as a replacement for the conventional blood-based monitoring of chronic kidney disease (CKD) and kidney failure owing to its cost effectiveness, non-invasiveness, excellent sensitivity, and capabilities for real-time measurement. The detection of ammonia for renal failure requires a biosensor with a detection limit of 1000 ppb (1 ppm). Among biosensors, plasmonic biosensors have attracted considerable research interest due to their potential for ultra-sensitivity, single particle/molecular level detection capability, multiplexing capability, photostability, real-time measurement, label-free measurement, room temperature operation, naked-eye readability, ease of miniaturization via simple sensor chip fabrication, and instrumentation, among other features. In this review, plasmonic sensors for the detection of ammonia gas relevant to kidney problems (LOD ≤ 1 ppm) are reviewed. In addition, the utilized strategies and surface functionalization for the plasmonic sensor are highlighted. Moreover, the main limitations of the reported sensors are stated for the benefit of future researchers. Finally, the challenges and prospects of plasmonic-based ammonia gas biosensors for potential application in the monitoring and screening of renal (kidney) failure, as well as the endpoint of the dialysis session, are stated.