The screening and early diagnosis of diseases are crucial for a patient’s treatment to be successful and to improve their survival rate, especially for cancer. The development of non-invasive analytical methods able to detect the biomarkers of pathologies is a critical point to define a successful treatment and a good outcome. This study extensively reviews the electrochemical methods used for the development of biosensors in a liquid biopsy, owing to their ability to provide a rapid response, precise detection, and low detection limits. We also discuss new developments in electrochemical biosensors, which can improve the specificity and sensitivity of standard analytical procedures. Electrochemical biosensors demonstrate remarkable sensitivity in detecting minute quantities of analytes, encompassing proteins, nucleic acids, and circulating tumor cells, even within challenging matrices such as urine, serum, blood, and various other body fluids. Among the various detection techniques used for the detection of cancer biomarkers, even in the picogram range, voltammetric sensors are deeply discussed in this review because of their advantages and technical characteristics. This widespread utilization stems from their ability to facilitate the quantitative detection of ions and molecules with exceptional precision. A comparison of each electrochemical technique is discussed to assist with the selection of appropriate analytical methods.
The removal of pollutants, such as heavy metals, aromatic compounds, dyes, pesticides and pharmaceuticals, from water is still an open challenge. Many methods have been developed and exploited for the purification of water from contaminants, including photocatalytic degradation, biological treatment, adsorption and chemical precipitation. Absorption-based techniques are still considered among the most efficient and commonly used approaches thanks to their operational simplicity. In recent years, polydopamine-coated magnetic nanoparticles have emerged for the uptake of heavy metals in water treatment, since they combine specific affinity towards pollutants and magnetic separation capacity. In this context, this work focuses on the synthesis of polydopamine (PDA)-coated Super Paramagnetic Iron Oxide Nanoparticles (PDA@SPIONs) as adsorbents for Cu2+ ions, designed to serve as functional nanostructures for the removal of Cu2+ from water by applying a magnetic field. The synthetic parameters, including the amount of SPIONs and PDA, were thoroughly investigated to define their effects on the nanostructure features and properties. Subsequently, the ability of the magnetic nanostructures to bind metal ions was assessed on Cu2+-containing solutions. A systematic investigation of the prepared functional nanostructures was carried out by means of complementary spectroscopic, morphological and magnetic techniques. Inductively coupled plasma atomic emission spectroscopy (ICP-AES) measurements were performed in order to estimate the Cu2+ binding ability. The overall results indicate that these nanostructures hold great promise for future bioremediation applications.
In this study, we present an innovative optical biosensor designed to detect Interleukin-6 (IL-6), a pivotal cytokine implicated in many pathological conditions. Our sensing platform is made of a porous silicon (PSi) nanostructured substrate modified with a thin (~5 nm) molecularly imprinted polymer (MIP), ensuring both high specificity and sensitivity toward IL-6 molecules. The fabrication process involves electrochemical etching of silicon chips to create the porous structure, followed by the electrodeposition of the MIP, which is tailored to selectively bind the IL-6 target. Extensive testing over a broad IL-6 concentration range demonstrates a clear, proportional optical response, yielding a limit of detection (LOD) of 13 nM. Moreover, the biosensor robustness was verified by evaluating its performance in bovine serum, a complex biological matrix. Despite the presence of various interfering components, the sensor maintained its selectivity and displayed minimal matrix effects, underlining its practical applicability in real-world diagnostic scenarios.
Screening and early diagnosis of diseases are crucial for a patient's treatment to be successful and to improve their survival rate, especially in cancer. The development of non-invasive analytical methods able to detect biomarkers of pathologies is a critical point to define a successful treat-ment and a good outcome. This study extensively reviews electrochemical methods used for the development of biosensors in liquid biopsy, owing to their ability to provide rapid response, pre-cise detection, and low detection limits. We also discuss new developments in electrochemical biosensors, which can improve the specificity and sensitivity of standard analytical procedures. Electrochemical biosensors demonstrate remarkable sensitivity in detecting minute quantities of analytes, encompassing proteins, nucleic acids, and circulating tumor cells, even within challeng-ing matrices such as urine, serum, blood, and various other body fluids. Among the various de-tection techniques used for the detection of cancer biomarkers, even in the picogram range, volt-ammetric sensors are deeply discussed in this review because of their advantages and technical characteristics. This widespread utilization stems from their ability to facilitate quantitative de-tection of ions and molecules with exceptional precision. The comparison of each electrochemical technique is discussed to provide the selection of appropriate analytical methods.