Paulina Ortega Bastidas

Paulina Ortega Bastidas

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PBPaulina Ortega Bastidas
Paulina Ortega Bastidas
BGBritam Gomez
Britam Gomez
Pablo AquevequePablo Aqueveque
Pablo Aqueveque
SLSoledad Luarte
Soledad Luarte
Roberto Cano de la CuerdaRoberto Cano de la Cuerda
Roberto Cano de la Cuerda
The Timed Up and Go (TUG) test is a widely used tool for assessing the risk of falls in older adults. However, to increase the test’s predictive value, the instrumented Timed Up and Go (iTUG) test has been developed, incorporating different technological approaches. This systematic review aims to explore the evidence of the technological proposal for the segmentation and analysis of iTUG in elderlies with or without pathologies. A search was conducted in five major databases, following PRISMA guidelines. The review included 40 studies that met the eligibility criteria. The most used technology was inertial sensors (75% of the studies), with healthy elderlies (35%) and elderlies with Parkinson’s disease (32.5%) being the most analyzed participants. In total, 97.5% of the studies applied automatic segmentation using rule-based algorithms. The iTUG test offers an economical and accessible alternative to increase the predictive value of TUG, identifying different variables, and can be used in clinical, community, and home settings.

6 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
PBPaulina Ortega Bastidas
Paulina Ortega Bastidas
Pablo AquevequePablo Aqueveque
Pablo Aqueveque
BGBritam Gomez
Britam Gomez
FSFrancisco Saavedra
Francisco Saavedra
Roberto Cano de la CuerdaRoberto Cano de la Cuerda
Roberto Cano de la Cuerda
Falls represent a major public health problem in the elderly population. The Timed Up & Go test (TU & Go) is the most used tool to measure this risk of falling, which offers a unique parameter in seconds that represents the dynamic balance. However, it is not determined in which activity the subject presents greater difficulties. For this, a feature-based segmentation method using a single wireless Inertial Measurement Unit (IMU) is proposed in order to analyze data of the inertial sensors to provide a complete report on risks of falls. Twenty-five young subjects and 12 older adults were measured to validate the method proposed with an IMU in the back and with video recording. The measurement system showed similar data compared to the conventional test video recorded, with a Pearson correlation coefficient of 0.9884 and a mean error of 0.17 ± 0.13 s for young subjects, as well as a correlation coefficient of 0.9878 and a mean error of 0.2 ± 0.22 s for older adults. Our methodology allows for identifying all the TU & Go sub–tasks with a single IMU automatically providing information about variables such as: duration of sub–tasks, standing and sitting accelerations, rotation velocity of turning, number of steps during walking and turns, and the inclination degrees of the trunk during standing and sitting.

14 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Pablo AquevequePablo Aqueveque
Pablo Aqueveque
BGBritam Gomez
Britam Gomez
EMEmyrna Monsalve
Emyrna Monsalve
Enrique Germany MorrisonEnrique Germany Morrison
Enrique Germany Morrison
PBPaulina Ortega Bastidas
Paulina Ortega Bastidas
EPEsteban Pino
Esteban Pino
This extended paper presents the development and implementation at a prototype level of a wireless, low-cost system for the measurement of the electrical bioimpedance of the chest with two channels using the AD5933 in a bipolar electrode configuration to measure impedance pneumography. The measurement device works for impedance measurements ranging from 1 Ω to 1800 Ω. Fifteen volunteers were measured with the prototype. We found that the left hemithorax has higher impedance compared to the right hemithorax, and the acquired signal presents the phases of the respiratory cycle with variations between 1 Ω, in normal breathing, to 6 Ω in maximum inhalation events. The system can measure the respiratory cycle variations simultaneously in both hemithorax with a mean error of −0.18 ± 1.42 BPM (breaths per minute) in the right hemithorax and −0.52 ± 1.31 BPM for the left hemithorax, constituting a useful device for the breathing rate calculation and possible screening applications.

1 June 2020 in Gait & Posture
Verified
Journal Article
Closed access
SCSergio Clavijo-Buendía
Sergio Clavijo-Buendía
Francisco MolinaFrancisco Molina
Francisco Molina
PMPatricia Martín-Casas
Patricia Martín-Casas
PBPaulina Ortega Bastidas
Paulina Ortega Bastidas
EMEsther Monge-Pereira
Esther Monge-Pereira
Roberto Cano de la CuerdaRoberto Cano de la Cuerda
Roberto Cano de la Cuerda

30 September 2024 in Technologies
Verified
Journal Article
Open access
PDF file
MGManuel Gutierrez
Manuel Gutierrez
BGBritam Gomez
Britam Gomez
GRGustavo Retamal
Gustavo Retamal
GPGuisella Peña
Guisella Peña
Enrique Germany MorrisonEnrique Germany Morrison
Enrique Germany Morrison
Pablo AquevequePablo Aqueveque
Pablo Aqueveque
Assessing musculoskeletal disorders (MSDs) in the workplace is vital for improving worker health and safety, reducing costs, and increasing productivity. Traditional hazard identification methods are often inefficient, particularly in detecting complex risks, which may compromise risk management. This study introduces a semi-automatic platform using two motion capture systems—an optical system (OptiTrack®) and a Bluetooth Low Energy (BLE)-based system with inertial measurement units (IMUs), developed at the Biomedical Engineering Laboratory, Universidad de Concepción, Chile. These systems, tested on 20 participants (10 women and 10 men, aged 30 ± 9 years without MSDs), facilitate risk assessments via the digitized NIOSH Index method. Analysis of ergonomically significant variables (H, V, A, D) and calculation of the RWL and LI showed both systems aligned with expected ergonomic standards, although significant differences were observed in vertical displacement (V), horizontal displacement (H), and trunk rotation (A), indicating areas for improvement, especially for the BLE system. The BLE Inertial MoCap system recorded mean heights of 33.87 cm (SD = 4.46) and vertical displacements of 13.17 cm (SD = 4.75), while OptiTrack® recorded mean heights of 30.12 cm (SD = 2.91) and vertical displacements of 15.67 cm (SD = 2.63). Despite the greater variability observed in BLE system measurements, both systems accurately captured vertical vertical absolute displacement (D), with means of 32.05 cm (SD = 7.36) for BLE and 31.80 cm (SD = 3.25) for OptiTrack®. Performance analysis showed high precision for both systems, with BLE and OptiTrack® achieving precision rates of 98.5%. Sensitivity, however, was lower for BLE (97.5%) compared to OptiTrack® (98.7%). The BLE system’s F1 score was 97.9%, while OptiTrack® scored 98.6%, indicating both systems can reliably assess ergonomic risk. These findings demonstrate the potential of using BLE-based IMUs for workplace ergonomics, though further improvements in measurement accuracy are needed. The user-friendly BLE-based system and semi-automatic platform significantly enhance risk assessment efficiency across various workplace environments.

22 June 2020 in European Journal of Translational Myology
Verified
Journal Article
Open access
PDF file
Pablo AquevequePablo Aqueveque
Pablo Aqueveque
BGBritam Gomez
Britam Gomez
FSFrancisco Saavedra
Francisco Saavedra
CCCristian Canales
Cristian Canales
SCSimón Contreras
Simón Contreras
Roberto Cano de la CuerdaRoberto Cano de la Cuerda
Roberto Cano de la Cuerda
There is a lack of commercially available low-cost technologies to assess gait clinically in non-controlled environments. As a consequence of this, there has been poor massification of motion measurement technologies that are both objective and reliable in nature. Advances about the study of gait and its interpretation in recent years using inertial sensors have allowed proposing acceptable alternatives for the development of portable and low-cost systems that contribute to people’s health in places and institutions that cannot acquire or maintain the operation of commercially available systems. A system based on a custom single Inertial Measurement Unit and a mobile application is proposed. Thus, an investigation is carried out using methodologies and algorithms found in the literature in order to get the main gait events and the spatial-temporal gait parameters. Twenty healthy Chilean subjects were assessed using a motion capture system simultaneously with the proposed tool. The results show that it is possible to estimate temporal gait parameters with slight differences respect gold--standard. We reach maximum mean differences of -2.35±5.02[step/min] for cadence, 0.03±0.04[sec] for stride time,0.02±0.03[sec] for step time, ±0.02[sec] for a single support time, 0.01±0.02[sec] for double support time and 0.01±0.03[m] for step length. As a result of experimental findings, we propose a new technological tool that can perform gait analysis. Our proposed system is user-friendly, low-cost, and portable. Therefore, we suggest that it could be an attractive technological tool that healthcare professionals could harness to objectively measure gait in environments that are either within the community or controlled. We also suggest that the tool could be used in countries where advanced clinical tools cannot be acquired. Therefore, we propose in this paper that our system is an attractive, alternative system that can be used for gait analysis by health professionals worldwide.