Pablo Aqueveque

Dr. Pablo Aqueveque

Department of Electrical Engineering, Faculty of Engineering, Universidad de Concepción, 219 Edmundo Larenas St., 4030000 Concepción, Chile
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2008 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
EWEduardo P. Wiechmann
Eduardo P. Wiechmann
Pablo AquevequePablo Aqueveque
Pablo Aqueveque
RBRolando Burgos
Rolando Burgos
Jose RodriguezJose Rodriguez
Jose Rodriguez
The energy performance of various types of voltage-source and current-source converters is examined. For fairness and completeness, efficiency is calculated for three major battleground scenarios. The first is a low dynamic nonregenerative group of applications such as pumps, fans, and compressors. This group represents 85% of high power (2 MW) industrial applications where energy savings are usually a primary consideration justifying investment. The second scenario considers applications requiring good dynamic response and regenerative braking. Finally, the third group considers very high power applications (over 20 MW). The evaluation presented takes into account semiconductor switching and conduction losses, losses in the medium voltage feeding transformer (determined per IEEE Standard C57.18.10-1998), and the losses in ac and dc filters. For purposes of analysis, computer simulations validated against measurements taken on a 1-MW voltage source inverter (VSI) and a 1.4-MW current source inverter (CSI) were used. The results of the first scenario show competitive efficiencies for VSI and CSI drives, whereas voltage source-based solutions are more energy efficient in the second scenario considered. For the last group, the current source load-commutated inverter exhibits the best performance.

24 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
PBPaulina Ortega Bastidas
Paulina Ortega Bastidas
BGBritam Gomez
Britam Gomez
Pablo AquevequePablo Aqueveque
Pablo Aqueveque
SLSoledad Luarte
Soledad Luarte
Roberto Cano de la CuerdaRoberto Cano de la Cuerda
Roberto Cano de la Cuerda
The Timed Up and Go (TUG) test is a widely used tool for assessing the risk of falls in older adults. However, to increase the test’s predictive value, the instrumented Timed Up and Go (iTUG) test has been developed, incorporating different technological approaches. This systematic review aims to explore the evidence of the technological proposal for the segmentation and analysis of iTUG in elderlies with or without pathologies. A search was conducted in five major databases, following PRISMA guidelines. The review included 40 studies that met the eligibility criteria. The most used technology was inertial sensors (75% of the studies), with healthy elderlies (35%) and elderlies with Parkinson’s disease (32.5%) being the most analyzed participants. In total, 97.5% of the studies applied automatic segmentation using rule-based algorithms. The iTUG test offers an economical and accessible alternative to increase the predictive value of TUG, identifying different variables, and can be used in clinical, community, and home settings.

24 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Pablo AquevequePablo Aqueveque
Pablo Aqueveque
Enrique Germany MorrisonEnrique Germany Morrison
Enrique Germany Morrison
RORodrigo Osorio
Rodrigo Osorio
FPFrancisco Pastene
Francisco Pastene
Gait analysis has been widely studied by researchers due to the impact in clinical fields. It provides relevant information on the condition of a patient’s pathologies. In the last decades, different gait measurement methods have been developed in order to identify parameters that can contribute to gait cycles. Analyzing those parameters, it is possible to segment and identify different phases of gait cycles, making these studies easier and more accurate. This paper proposes a simple gait segmentation method based on plantar pressure measurement. Current methods used by researchers and clinicians are based on multiple sensing devices (e.g., multiple cameras, multiple inertial measurement units (IMUs)). Our proposal uses plantar pressure information from only two sensorized insoles that were designed and implemented with eight custom-made flexible capacitive sensors. An algorithm was implemented to calculate gait parameters and segment gait cycle phases and subphases. Functional tests were performed in six healthy volunteers in a 10 m walking test. The designed in-shoe insole presented an average power consumption of 44 mA under operation. The system segmented the gait phases and sub-phases in all subjects. The calculated percentile distribution between stance phase time and swing phase time was almost 60%/40%, which is aligned with literature reports on healthy subjects. Our results show that the system achieves a successful segmentation of gait phases and subphases, is capable of reporting COP velocity, double support time, cadence, stance phase time percentage, swing phase time percentage, and double support time percentage. The proposed system allows for the simplification of the assessment method in the recovery process for both patients and clinicians.

14 June 2017
Verified
Book Chapter
Open access
PDF file
Pablo AquevequePablo Aqueveque
Pablo Aqueveque
POPaulina Ortega
Paulina Ortega
EPEsteban Pino
Esteban Pino
FSFrancisco Saavedra
Francisco Saavedra
Enrique Germany MorrisonEnrique Germany Morrison
Enrique Germany Morrison
BGBritam Gómez
Britam Gómez
After Stroke Movement Impairments: A Review of Current Technologies for Rehabilitation | InTechOpen, Published on: 2017-06-14. Authors: Pablo Aqueveque, Paulina Ortega, Esteban Pino, et

6 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
PBPaulina Ortega Bastidas
Paulina Ortega Bastidas
Pablo AquevequePablo Aqueveque
Pablo Aqueveque
BGBritam Gomez
Britam Gomez
FSFrancisco Saavedra
Francisco Saavedra
Roberto Cano de la CuerdaRoberto Cano de la Cuerda
Roberto Cano de la Cuerda
Falls represent a major public health problem in the elderly population. The Timed Up & Go test (TU & Go) is the most used tool to measure this risk of falling, which offers a unique parameter in seconds that represents the dynamic balance. However, it is not determined in which activity the subject presents greater difficulties. For this, a feature-based segmentation method using a single wireless Inertial Measurement Unit (IMU) is proposed in order to analyze data of the inertial sensors to provide a complete report on risks of falls. Twenty-five young subjects and 12 older adults were measured to validate the method proposed with an IMU in the back and with video recording. The measurement system showed similar data compared to the conventional test video recorded, with a Pearson correlation coefficient of 0.9884 and a mean error of 0.17 ± 0.13 s for young subjects, as well as a correlation coefficient of 0.9878 and a mean error of 0.2 ± 0.22 s for older adults. Our methodology allows for identifying all the TU & Go sub–tasks with a single IMU automatically providing information about variables such as: duration of sub–tasks, standing and sitting accelerations, rotation velocity of turning, number of steps during walking and turns, and the inclination degrees of the trunk during standing and sitting.

14 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Pablo AquevequePablo Aqueveque
Pablo Aqueveque
BGBritam Gomez
Britam Gomez
EMEmyrna Monsalve
Emyrna Monsalve
Enrique Germany MorrisonEnrique Germany Morrison
Enrique Germany Morrison
PBPaulina Ortega Bastidas
Paulina Ortega Bastidas
EPEsteban Pino
Esteban Pino
This extended paper presents the development and implementation at a prototype level of a wireless, low-cost system for the measurement of the electrical bioimpedance of the chest with two channels using the AD5933 in a bipolar electrode configuration to measure impedance pneumography. The measurement device works for impedance measurements ranging from 1 Ω to 1800 Ω. Fifteen volunteers were measured with the prototype. We found that the left hemithorax has higher impedance compared to the right hemithorax, and the acquired signal presents the phases of the respiratory cycle with variations between 1 Ω, in normal breathing, to 6 Ω in maximum inhalation events. The system can measure the respiratory cycle variations simultaneously in both hemithorax with a mean error of −0.18 ± 1.42 BPM (breaths per minute) in the right hemithorax and −0.52 ± 1.31 BPM for the left hemithorax, constituting a useful device for the breathing rate calculation and possible screening applications.