Rex Tan

Dr. Rex Tan

AEvice Health
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2019 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
WLWenjie Lai
Wenjie Lai
LCLin Cao
Lin Cao
RTRex Tan
Rex Tan
PPPhuoc Thien Phan
Phuoc Thien Phan
JHJianzhong Hao
Jianzhong Hao
SPSoo Jay Phee
Soo Jay Phee

13 November 2018 in ACS Sensors
Verified
Journal Article
Closed access
SYStephanie Hui Kit Yap
Stephanie Hui Kit Yap
YCYi-Hsin Chien
Yi-Hsin Chien
RTRex Tan
Rex Tan
AAAbdul Rahman bin Shaik Alauddin
Abdul Rahman bin Shaik Alauddin
WJWen Bin Ji
Wen Bin Ji
KYKen-Tye Yong
Ken-Tye Yong

5 June 2018 in Sensors
Verified
Journal Article
Open access
PDF file
RTRex Tan
Rex Tan
SYStephanie Hui Kit Yap
Stephanie Hui Kit Yap
YTYung Chuen Tan
Yung Chuen Tan
Swee Chuan TjinSwee Chuan Tjin
Swee Chuan Tjin
MIMorten Ibsen
Morten Ibsen
WLWenn Jing Lai
Wenn Jing Lai
We present a novel superstructure fiber Bragg grating fiber end sensor capable of detecting variations in refractive index (RI) of liquids and potentially that of gases, and demonstrated an application in the detection of heavy metal ions in water. The sensor is capable of sensing RI variations in the range of 1.333 to 1.470 with good sensitivity of up to 230 dB/RIU achieved for the RI range of 1.370 to 1.390. The sensor is capable of simultaneously measuring variations in ambient temperature along with RI. A simple chemical coating was employed as a chelating agent for heavy metal ion detection at the fiber end to demonstrate an possible application of the sensor. The coated fiber sensor can conclusively detect the presence of heavy metal ions with concentrations upwards of 100 ppm. RI sensing capability of the sensor is neither affected by temperature nor strain and is both robust and easily reproducible.

29 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
RTRex Tan
Rex Tan
DHDaryl Ho
Daryl Ho
CTChun Ho Tse
Chun Ho Tse
YTYung Chuen Tan
Yung Chuen Tan
SYSeongwoo Yoo
Seongwoo Yoo
MIMorten Ibsen
Morten Ibsen
We demonstrate a simple-to-fabricate refractometer based on the inscription of fiber Bragg gratings in a special C-shaped optical fiber. The C-shaped fiber was drawn into shape using a quarter cladding removed preform of a commercial standard single-mode fiber by simple machining. The sensor did not suffer from cross-sensitivity of the refractive index with ambient temperature fluctuations, commonly occurring with many optical fiber refractometers. A refractive index sensitivity of 1300 pm per refractive index unit (RIU) was achieved without employing any additional sensitization techniques such as tapering or etching.

5 December 2019 in Chemosensors
Verified
Journal Article
Open access
PDF file
RTRex Tan
Rex Tan
MIMorten Ibsen
Morten Ibsen
Swee Chuan TjinSwee Chuan Tjin
Swee Chuan Tjin
Research into optical fiber refractometers yielded remarkable results over the past decade. Numerous sensing schemes were proposed and demonstrated, which possessed different advantages while facing unique limitations. On top of their obvious applications in measuring refractive index changes of the ambient environment, several studies reported advanced applications of such sensors in heavy metal ion detection by means of surface coating of the refractometers with heavy metal ion sensitive materials. This paper surveys the effort these optical fiber metal ion sensors based on surface coated optical fiber refractometer, discusses different technologies and methods involved, and highlights recent notable advancements.

10 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
BXBing Xue
Bing Xue
WSWen Shi
Wen Shi
SCSanjay Haresh Chotirmall
Sanjay Haresh Chotirmall
VKVivian Ci Ai Koh
Vivian Ci Ai Koh
YAYi Yang Ang
Yi Yang Ang
Wee SerWee Ser
Wee Ser
Smart wearable sensors are essential for continuous health-monitoring applications and detection accuracy of symptoms and energy efficiency of processing algorithms are key challenges for such devices. While several machine-learning-based algorithms for the detection of abnormal breath sounds are reported in literature, they are either too computationally expensive to implement into a wearable device or inaccurate in multi-class detection. In this paper, a kernel-like minimum distance classifier (K-MDC) for acoustic signal processing in wearable devices was proposed. The proposed algorithm was tested with data acquired from open-source databases, participants, and hospitals. It was observed that the proposed K-MDC classifier achieves accurate detection in up to 91.23% of cases, and it reaches various detection accuracies with a fewer number of features compared with other classifiers. The proposed algorithm’s low computational complexity and classification effectiveness translate to great potential for implementation in health-monitoring wearable devices.