The paper describes a novel transmission electron microscopy (TEM) experiment with in situ ion irradiation designed to improve and validate a computer model. TEM thin foils of molybdenum were irradiated in situ by 1 MeV Kr ions up to ∼0.045 displacements per atom (dpa) at 80°C at three dose rates −5 × 10−6, 5 × 10−5, and 5 × 10−4 dpa/s – at the Argonne IVEM-Tandem Facility. The low-dose experiments produced visible defect structure in dislocation loops, allowing accurate, quantitative measurements of defect number density and size distribution. Weak beam dark-field plane-view images were used to obtain defect density and size distribution as functions of foil thickness, dose, and dose rate. Diffraction contrast electron tomography was performed to image defect clusters through the foil thickness and measure their depth distribution. A spatially dependent cluster dynamic model was developed explicitly to model the damage by 1 MeV Kr ion irradiation in an Mo thin foil with temporal and spatial dependence of defect distribution. The set of quantitative data of visible defects was used to improve and validate the computer model. It was shown that the thin foil thickness is an important variable in determining the defect distribution. This additional spatial dimension allowed direct comparison between the model and experiments of defect structures. The defect loss to the surfaces in an irradiated thin foil was modeled successfully. TEM with in situ ion irradiation of Mo thin foils was also explicitly designed to compare with neutron irradiation data of the identical material that will be used to validate the model developed for thin foils.
β-Ga2O3 was suggested to have excellent irradiation hardness which makes β-Ga2O3-based devices extremely attractive for nuclear and space applications. To discern the fundamental nano-scale structural changes with irradiation, an in situ irradiation experiment in a transmission electron microscope was carried out using 400 keV Ar ions of fluences up to 8 × 1015 cm−2 (equivalent to four displacements per atom). Contrary to previous works, which indicate a phase transition of β-Ga2O3 into the κ polymorph, the β-Ga2O3 structure was found to remain intact throughout except for (i) anisotropic lattice distortions, which are most significant at low levels of irradiation, and (ii) the appearance of additional weak reflections above 2 dpa irradiation. The origin of the extra reflections is discussed.
We present an in situ Radiated Materials (iRadMat) experimental module designed to interface with a servo-hydraulic load frame for X-ray measurements at beamline 1-ID at the Advanced Photon Source. This new capability allows in situ studies of radioactive specimens subject to thermo-mechanical loading using a suite of high-energy X-ray scattering and imaging techniques. The iRadMat is a radiation-shielded vacuum heating system with the sample rotation-under-load capability. We describe the design features and performances of the iRadMat and present a dataset from a 300 °C uniaxial tensile test of a neutron-irradiated pure Fe specimen to demonstrate its capabilities.