To study the influence of different water–binder ratios on the corrosion, permeability, and freezing properties of concrete, we produced different strengths of concrete with respective water–binder ratios of 0.32, 0.38, 0.50, and 0.66. The corrosion resistance of the concrete was studied via three corrosion methods: full immersion, half immersion, and dry and wet cycles. The impermeability and frost resistance of concrete with different water–binder ratios were tested and analyzed. The test results show that the corrosion modes in order from strong to weak were dry and wet cycles, half soaking, and full soaking. The relative dynamic elasticity modulus and freeze–thaw index were used to evaluate the frost resistance of concrete based on the analysis of three indices of frost resistance. To study the internal mechanism of corrosion of concrete with different water–binder ratios, microscopic pore structure testing of the concrete was conducted using a Micromeritics AutoPore IV 9500 Series instrument. The porosimeter studies show that the smaller the water–binder ratio, the more small pores and the denser the concrete. The smaller the water–binder ratio, the higher the strength and the better the corrosion, permeability, and frost resistance.
To study different lateral restraints, different constituents of expansion agents, the influence of different steel ratios, and concrete creep properties, we carried out experiments with lateral restraint and without lateral restraint conditions separately on 12 specimens with the expansion agent content accounting for 4%, 8%, and 12% respectively. In addition, the creep tests were performed on specimens with different steel ratios of 0.0%, 3.8%, 6.6%, and 9.2%. The test results show that the lateral restraint improves the strength of the system (concrete-filled steel tubes) which resists further load after the concrete ultimate strength is surpassed and reduces the creep. The creep degree of the concrete-filled steel tube with lateral restraint is about 0.09–0.30 times smaller than that of the tube without lateral restraints. The creep degree of the concrete-filled steel tube increases as the steel ratio decreases. Creep tests with different amounts of expansion agent indicate that the creep degree of the concrete structure increases as expansion agent content decreases. To study the internal mechanism of the creep of concrete-filled steel tubes with different lateral restraints and different expansion agent concentrations, a microscopic pore structure test on the steel core concrete was conducted using the RapidAir457 pore structure instrument. Microscopic studies show that the air content and the length of the bubble chord of the laterally restrained core concrete are lower than those without lateral restraint core concrete. The amount of air content and the length of the bubble chord of core concrete specimens increase as the expansion agent content in the core concrete specimens decreases from 12% to 4%. Under the same external loading conditions, as steel ratio increases, the lateral restraint causes a further reduction of creep. The results of this study suggest that the creep of concrete can be reduced by selecting appropriate lateral restraint conditions and an optimal amount of expansion agent in the mix design of concrete for concrete-filled steel tubes.
This study evaluates the impact of compaction on the soil–water characteristic curve of unsaturated remodeled weakly expansive soils by assessing changes in soil pore structure resulting from variations in compaction. The remodeled weakly expansive soil in the Xinjiang Hami area is taken as the research subject to investigate how compaction affects microscopic pore structure using mercury intrusion testing. Subsequently, mercury intrusion porosimetry is employed to examine pore structure and distribution patterns at different dry densities. Based on the capillary principle and experimental methods (filter paper method and pressure plate method test), modified soil–water characteristic curves are obtained by fitting them with a three-parameter model law. The results indicate that higher dry density leads to an increased air intake value and significantly reduces the total volume of large pores within samples. Both the Fredlund and Xing model and the three-parameter model effectively capture the influence of initial dry density on the development pattern of the soil–water characteristic curve.