Mehmet Aytac CINAR

Dr. Mehmet Aytac CINAR

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Engineering Failure Analysis
Verified
Journal Article
Closed access
BABora Alboyací
Bora Alboyací
MCMehmet Aytac CINAR
Mehmet Aytac CINAR
YDYunus Berat Demirol
Yunus Berat Demirol
AIAdem Ince
Adem Ince

30 July 2022 in Engineering Failure Analysis
Verified
Journal Article
Closed access
BABora Alboyací
Bora Alboyací
MCMehmet Aytac CINAR
Mehmet Aytac CINAR
YDYunus Berat Demirol
Yunus Berat Demirol
MUMete Uzar
Mete Uzar

23 August 2017 in International Journal of Engineering and Applied Sciences
Verified
Journal Article
Open access
Kamran DawoodKamran Dawood
Kamran Dawood
MCMehmet Aytac CINAR
Mehmet Aytac CINAR
BABora Alboyací
Bora Alboyací
OSOlus Sonmez
Olus Sonmez
Different transformer models are examined for the calculation of the no-load losses using finite element analysis. Two-dimensional and three-dimensional finite element analyses are used for the simulation of the transformer. Results of the finite element method are also compared with the experimental results. The Result shows that 3-dimensional provide high accuracy as compared to the 2 dimensional full and half model. However, the 2-dimensional half model is the less time-consuming method as compared to the 3 and 2-dimensional full model. Simulation time duration taken by the different models of the transformer is also compared. The difference between the 3-dimensional finite element method and experimental results are less than 3%. These numerical methods can help transformer designers to minimize the development of the prototype transformers.

8 December 2017 in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
Verified
Journal Article
Closed access
PDF file
MCMehmet Aytac CINAR
Mehmet Aytac CINAR
BABora Alboyací
Bora Alboyací
SÇSerenay Çürükova
Serenay Çürükova
OSOluş Sönmez
Oluş Sönmez
RYRauf Yapıcı
Rauf Yapıcı
Normal 0 21 false false false TR X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Normal Tablo"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; line-height:115%; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri",sans-serif; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi; mso-fareast-language:EN-US;} Yağlı tip transformatörlerdeki kazan ve diğer metal yapısal elemanlar üzerinde meydana gelen güç kayıpları, toplam kayıpların azaltılmasına yönelik olarak gerçekleştirilen çalışmalarda göz önünde tutulması gereken etkenlerden biridir. Bu kayıplar sargıların çevresindeki kaçak akılar sebebiyle transformatörün yapısal metal parçaları üzerinde oluşmakta ve bu parçalarda aşırı ısınmaya yol açmaktadır. Bu çalışmada, kazan duvarları üzerinde meydana gelen bu kayıpları azaltmak amacıyla kazan duvarlarının iç yüzeyine yerleştirilen şönt elemanların en uygun boyutlarının belirlenmesi amaçlanmaktadır. Bu doğrultuda özel olarak tasarlanan bir transformatör için sonlu elemanlar yöntemi kullanılarak elektromanyetik analizler gerçekleştirilmiş olup, analiz sonuçları deneysel çalışmalar ile doğrulanmıştır. Elde edilen sonuçlar ile kazan duvarlarının iç yüzeyine yerleştirilecek en uygun şönt boyutları transformatörün sargı boyutlarına bağlı olarak ifade edilmektedir. Belirlenen boyutlardaki şönt elemanların kullanımı ile kazan duvarlarında meydana gelen kayıpların %91,43, toplam kısa devre kayıplarının ise %14,9 oranında azaltılması mümkün olmuştur.

21 August 2024 in Energies
Verified
Journal Article
Open access
PDF file
MCMehmet Aytac CINAR
Mehmet Aytac CINAR
Transformers are among the most important components in the energy grid due to their missions and high costs. The challenging operating conditions deteriorate their components and shorten the life of the transformers. The health index approach is a critical and effective method for monitoring transformers in the operating environment, early diagnosis of possible malfunctions, and evaluation of their general condition. DGA, OQA, and PIF parameters, which represent the condition of the insulation materials, which mainly determine the life of transformers, constitute the basic inputs of the health index approach. In this study, a new method was proposed to determine the DGAF score based on the dissolved gases in mineral oil. With this method, in addition to the delta and rate values of the gases, the past DGA results of the transformer were also considered in determining the DGAF. In this way, faults experienced during operation are included in the health index calculation. The proposed method was tested using 36 DGA results obtained over a period of approximately 10 years from a transformer operating in the grid. The obtained results are presented in comparison with the traditional DGAF scoring method.

31 July 2022 in Demiryolu Mühendisliği
Verified
Journal Article
Closed access
PDF file
SÇSerenay Çürükova
Serenay Çürükova
YDYunus Berat Demirol
Yunus Berat Demirol
OSOluş SÖNMEZ
Oluş SÖNMEZ
MCMehmet Aytac CINAR
Mehmet Aytac CINAR
BABora Alboyací
Bora Alboyací
Demiryolu sistemlerinde kullanılan elektrikli trenlerin hareket gücünü sağlamak için kullanılan motor sürücülerini cer transformatörleri beslemektedir. Cer transformatörleri lokomotiflerin altında veya üstünde, boyutları sınırlı bir alana yerleştirilmektedir. Bunun yanında tren sistemlerinde kullanılmakta olan ekipmanların güç ihtiyaçlarını karşılayabilmek için farklı gerilim seviyelerinde çok sayıda sargı yapıları cer transformatörlerinde bulunmaktadır. Demiryolu sistemlerinde sürdürülebilirlik, verim ve işletme güvenliğinin yüksek seviyede olması için cer transformatörlerinin tasarım parametrelerinin özel olarak incelenmesi gerekmektedir. Bu kapsamda tasarım aşamasında detaylı analizlerin gerçekleştirilmesi ve standartlar referans alınarak değerlendirilmesi önemli olmaktadır. Cer transformatörlerinde kısa devre empedansı, inrush akımları, kazan kayıpları, çekirdek kayıpları gibi kritik öneme sahip elektriksel parametrelerin doğru bir şekilde hesaplanması teorik yöntemler ile her zaman mümkün olmamakta veya çok zahmetli olmaktadır. Bu durumda sonlu elemanlar analizi yönteminin birçok açıdan avantajı bulunmaktadır. Sonlu elemanlar analizleri ile yüksek doğrulukta ve kısa sürede hesaplamalar yapılabilmektedir. Bu çalışmada örnek bir cer transformatörünün elektriksel parametreleri Ansys Electronics Suite sonlu elemanlar analizi yazılımı ile hesaplanmıştır. Hesaplanan parametreler ile ilgili olarak özet bilgiler verilmiş, analiz adımları açıklanmıştır. Bu kapsamda demiryolu sistemlerinde kullanılan trenlerin kritik elemanlarından biri olan cer transformatörlerinin elektriksel analizi için sonlu elemanlar yönteminin gerekliliği ifade edilmiştir.