Carolin Gabler

Ms. Carolin Gabler


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
CGCarolin Gabler
Carolin Gabler
CZCarmen Zietz
Carmen Zietz
RGRebecca Göhler
Rebecca Göhler
AFAndreas Fritsche
Andreas Fritsche
TLTobias Lindner
Tobias Lindner
RBRainer Bader
Rainer Bader
By means of plasma polymerization, positively charged, nanometre-thin coatings can be applied to implant surfaces. The aim of the present study was to quantify the adhesion of human bone cells in vitro and to evaluate the bone ongrowth in vivo, on titanium surfaces modified by plasma polymer coatings. Different implant surface configurations were examined: titanium alloy (Ti6Al4V) coated with plasma-polymerized allylamine (PPAAm) and plasma-polymerized ethylenediamine (PPEDA) versus uncoated. Shear stress on human osteoblast-like MG-63 cells was investigated in vitro using a spinning disc device. Furthermore, bone-to-implant contact (BIC) was evaluated in vivo. Custom-made conical titanium implants were inserted at the medial tibia of female Sprague-Dawley rats. After a follow-up of six weeks, the BIC was determined by means of histomorphometry. The quantification of cell adhesion showed a significantly higher shear stress for MG-63 cells on PPAAm and PPEDA compared to uncoated Ti6Al4V. Uncoated titanium alloyed implants showed the lowest BIC (40.4%). Implants with PPAAm coating revealed a clear but not significant increase of the BIC (58.5%) and implants with PPEDA a significantly increased BIC (63.7%). In conclusion, plasma polymer coatings demonstrate enhanced cell adhesion and bone ongrowth compared to uncoated titanium surfaces.

1 January 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
CGCarolin Gabler
Carolin Gabler
CZCarmen Zietz
Carmen Zietz
RBRichard Bieck
Richard Bieck
RGRebecca Göhler
Rebecca Göhler
TLTobias Lindner
Tobias Lindner
RBRainer Bader
Rainer Bader
A common method to derive both qualitative and quantitative data to evaluate osseointegration of implants is histomorphometry. The present study describes a new image reconstruction algorithm comparing the results of bone-to-implant contact (BIC) evaluated by means ofµCT with histomorphometry data. Custom-made conical titanium alloyed (Ti6Al4V) implants were inserted in the distal tibial bone of female Sprague-Dawley rats. Different surface configurations were examined: Ti6Al4V implants with plasma-polymerized allylamine (PPAAm) coating and plasma-polymerized ethylenediamine (PPEDA) coating as well as implants without surface coating. After six weeks postoperatively, tibiae were explanted and BIC was determined byµCT (3D) and afterwards by histomorphometry (2D). In comparison to uncoated Ti6Al4V implants demonstrating low BIC of 32.4% (histomorphometry) and 51.3% (µCT), PPAAm and PPEDA coated implants showed a nonsignificant increase in BIC (histomorphometry: 45.7% and 53.5% andµCT: 51.8% and 62.0%, resp.). Mean BIC calculated byµCT was higher for all surface configurations compared to BIC detected by histomorphometry. Overall, a high correlation coefficient of 0.70 (p<0.002) was found between 3D and 2D quantification of BIC. TheμCT analysis seems to be suitable as a nondestructive and accurate 3D imaging method for the evaluation of the bone-implant interface.

8 August 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
CGCarolin Gabler
Carolin Gabler
JSJan-Oliver Saß
Jan-Oliver Saß
SGSusann Gierschner
Susann Gierschner
TLTobias Lindner
Tobias Lindner
RBRainer Bader
Rainer Bader
TTThomas Tischer
Thomas Tischer
In the present study, a newly introduced bovine cross-linked collagen scaffold (test material) was investigated in vivo in an Achilles tendon defect model and compared to a commercially available porcine collagen scaffold (control material). In total, 28 male Sprague Dawley rats (about 400 g) were examined. The defined Achilles tendon defect of 5 mm of the right hind limb was replaced by one of the scaffold materials. After euthanasia, the hind limbs were transected for testing. Biomechanical evaluation was carried out via tensile testing (n = 8 each group, observation time: 28 days). Nonoperated tendons from the bilateral side were used as a control (native tendon, n = 4). For the histological evaluation, 12 animals were sacrificed at 14 and 28 days postoperatively (n = 3 each group and time point). Stained slices (Hematoxylin & Eosin) were evaluated qualitatively in terms of presence of cells and cell migration into scaffolds as well as structure and degradation of the scaffold. All transected hind limbs were additionally analyzed using MRI before testing to verify if the tendon repair using a collagen scaffold was still intact after the observation period. The maximum failure loads of both scaffold materials (test material: 54.5 ± 16.4 N, control: 63.1 ± 19.5 N) were in the range of native tendon (76.6 ± 11.6 N, p ≥ 0.07). The stiffness of native tendons was twofold higher (p ≤ 0.01) and the tear strength was approximately fivefold higher (p ≤ 0.01) compared to the repaired tendons with both scaffolds. Histological findings indicated that neither the test nor the control material induced inflammation, but the test material underwent a slower remodeling process. An overall repair failure rate of 48% was observed via MRI. The experimental data of the newly developed test material showed similar outcomes compared to the commercially available control material. The high repair failure rate indicated that MRI is recommended as an auxiliary measurement tool to validate experimental data.

9 May 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
CGCarolin Gabler
Carolin Gabler
JSJuliane Spohn
Juliane Spohn
TTThomas Tischer
Thomas Tischer
RBRainer Bader
Rainer Bader
Tendon augmentation is increasingly clinically relevant due to rising amount of tendon ruptures because of the aging and more demanding population. Therefore, newly developed scaffolds based on bovine epoxide stabilized collagen maintaining the native fibril-like collagen structure were characterized and compared to two commercially available porcine collagen scaffolds. For biomechanical testing (ultimate load, ultimate stress, stiffness, and elastic modulus), bovine collagen scaffolds were hydrated and compared to reference products. Cell viability and proliferation were assessed by seeding human primary fibroblasts on each collagen-based scaffold and cultured over various time periods (3 d, 7 d, and 14 d). Live/dead staining was performed and metabolic cell activity (WST-1 assay) was measured. Biochemical degradability was investigated by enzymatic digestion. The bovine collagen scaffold showed significantly enhanced biomechanical properties. These persisted over different rehydration times. Cell biological tests revealed that the bovine collagen scaffolds support reproducible cell colonization and a significant increase in the number of viable cells during cultivation. The results are comparable with the viability and proliferation rate of cells grown on porcine reference materials. With regard to biochemical degradability, all tested materials showed comparable resistance to enzymatic degradation in vitro. Due to imitating the natural tendon structure the new scaffold material is supposed to provide beneficial effects in future clinical application.

20 October 2015 in Trauma und Berufskrankheit
Verified
Journal Article
Open access
PDF file
MMMatthias Militz
Matthias Militz
CGCarolin Gabler
Carolin Gabler
JMJosephine Mauck
Josephine Mauck
CMChristoph Miethke
Christoph Miethke
RBRobert Bialas
Robert Bialas
RBRainer Bader
Rainer Bader
Zusammenfassung Tumorchirurgische Eingriffe und Folgezustände operativer Knochenbruchbehandlungen mit komplizierten Verläufen, besonders nach Infektionen, gehen häufig mit großen Knochendefekten einher. Neben der Defektüberbrückung durch allogene Implantate stellen die Defektrekonstruktion durch Segmenttransport und die Kallusdistraktion sowie der vaskularisierte Knochentransfer die Verfahren der Wahl zur Defektrekonstruktion an langen Röhrenknochen dar. Die Heterogenität der Ursachen der Knochendefekte und der spezifischen Begleitumstände der Patienten erfordern ein differenziertes Vorgehen. Die Indikationen und Besonderheiten der verschiedenen operativen Ansätze sowie aktuelle Verfahrensentwicklungen zur Rekonstruktion großer Defekte an langen Röhrenknochen werden dargestellt.

1 January 2018
Verified
Journal Article
Closed access
CGCarolin Gabler
Carolin Gabler
SGSusann Gierschner
Susann Gierschner
TTThomas Tischer
Thomas Tischer
RBRainer Bader
Rainer Bader