Unbalanced voltage fluctuation at the point of common coupling (PCC) is a challenging power quality problem in power distribution system. This study presents an unbalanced PCC voltage regulation scheme with positive‐ and negative‐sequence control for modular multilevel converter (MMC) in medium‐voltage distribution static synchronous compensator (DSTATCOM) application. The proposed positive‐sequence control is utilised to regulate the positive‐sequence component of PCC voltage to rated value, while the negative‐sequence control aims to cancel out the negative‐sequence component of PCC voltage completely. Compensation commands whether in positive‐ or negative‐sequence control are generated from unbalanced PCC voltage without utilisation of unbalanced load currents. DC circulating currents transferring active power among three phases of MMC are also analysed to illustrate power balance issue resulting from negative‐sequence control. Then comparison of negative‐sequence compensation capacity between MMC and full‐bridge cascaded converter with delta‐connection is illustrated. Experiment results acquired from a downscaled 85 V/1.5 kVA apparatus validate the effectiveness of the proposed control scheme.
28 September 2018 in IEEE Transactions on Industry Applications
This paper addresses the stability analysis of shunt active power filter (SAPF) with capacitive load for selective harmonic suppression and resonance damping. If the capacitive load current is measured as part of harmonic suppression current reference, the SAPF with conventional selective harmonic suppression would amplify the corresponding harmonic beyond resonance frequency. Previous studies could not clearly explain this harmonic amplification phenomenon without the selective harmonic extraction model in stability analysis. By viewing discrete Fourier transform (DFT) as cluster of band-pass filter (BPF), the modeling process is taken into consideration and is well simplified. The stability condition for suppressing and damping each selected harmonic can be easily estimated with the help of Nyquist stability criterion or root locus method in different SAPF control scenarios. To avoid the instability and compensate the harmonic current, a novel combined control strategy of SAPF is carried out to simultaneously suppress the harmonics whose frequencies are lower than the resonance frequency and mitigate the rest of harmonics by resonance damping method. Experiments have been performed to verify the effectiveness of the proposed strategy.
Shunt active power filter (SAPF) is conventionally designed to compensate harmonic currents from non‐linear load. However, due to parallel resonance between line impedance and capacitive load, the distortion of the voltage at point of common coupling (PCC) and grid current may not be mitigated completely by traditional manner of SAPF. This paper investigates harmonic compensation and resonance damping combined control for SAPF with selective closed‐loop regulation of PCC voltage. Through developing equivalent circuit model, physical principle of SAPF with the proposed scheme is analysed as well as resonance frequency shifting phenomenon. To compensate specified harmonic currents, compensation reference is extracted flexibly by means of improved recursive discrete Fourier transform algorithm with phase‐angle compensation. Meanwhile, selective virtual conductance with proportional–integral (PI) regulation of PCC voltage is proposed to damp parallel resonance. Then, a zero steady‐state error controller composed of ordinary PI and advanced repetitive controller in parallel under synchronous rotation frame is adopted to improve current tracking performance of SAPF. Experimental results are provided to verify the effectiveness of the proposed method.
Shunt active power filter (APF), with higher switching frequency, has a potential market for suppressing wideband harmonics in the more electric aircraft (MEA) or high-speed train (HST) power grid. In this case, the selective extraction of harmonic current reference is essential. Recursive discrete Fourier transform (RDFT) is widely adopted for its excellent selectivity and low computational burden. However, RDFT is tough to implement in the higher frequency APF with the shorter switching cycle, and suffers from the demerit of slow dynamics. To alleviate those, three improved RDFTs are proposed in this paper. Firstly, it is revealed that RDFT can be regarded as a series of DFT and inverse-DFT (IFT), and its settling time depends on the comb filter of DFT. Then, by rearranging the sampling frequency of DFT according to the extracted harmonic, the computational burden of twice-sampling RDFT (TS-RDFT) is reduced while satisfying the same extraction accuracy. Furtherly, to improve the dynamics of TS-RDFT while retaining the merits of simplicity and selectivity, the comb filter is reconfigured based on the load current spectrum. For balanced loads, the settling time of TS-RDFT can be shortened from 1 to 1/6 fundamental cycle in the synchronous reference frame. For unbalanced loads, it is shortened to 1/2 cycle in the $\alpha \beta $ frame. Finally, the simulations with Matlab for harmonic extraction in 400Hz grid and the experiments with the APF prototype for harmonic suppression in 50Hz grid are carried out to verify the effectiveness of the proposed methods.
This study presents a kind of three‐phase three‐wire double‐star‐type transformer‐less modular multilevel converters (MMCs) in medium‐voltage distribution static synchronous compensators (DSTATCOMs) application based on pulse‐width‐modulated cascaded half‐bridge modules. An advanced steady‐state analysis for arm current and capacitor voltage is presented to give the explicit converter performance evaluation in project installation. Two key equations based on first and second component equivalent circuits are formulated to obtain the undetermined circulating second harmonic current and actual modulation index. Based on the proposed analysis, the internal active and reactive power control and the external droop control for the voltage at the point of common coupling (PCC) are introduced for MMC‐DSTATCOM, respectively. The droop control enlarges the operation area of the converter and the PCC voltage is allowed to vary in a larger acceptable range. Experiment tests acquired from a 60 V/2 kVA prototype in a simplified downscaled power distribution system verify the accuracy of the analysis and the feasibility of the PCC voltage droop control simultaneously.
With the rapid increase in the penetration rate of renewable energy, the power quality of grid-connected wind farm is deteriorated seriously with power fluctuation and point of common coupling (PCC) voltage instability. The conventional solution is to use the energy storage device and the reactive power compensation apparatus to adjust separately, which complicates the system structure. Besides, an active power filter is needed additionally when harmonic pollution caused by local nonlinear load is serious. To solve these problems, this paper investigates the modular multilevel converter-based battery energy storage system (MMC-BESS), which can realize fluctuating power suppression, PCC voltage regulation, and harmonic mitigation simultaneously in grid-connected wind farm. Firstly, the topology and energy flow of MMC-BESS have been studied. Then, three-layer balance control of the state of charge (SOC) is proposed, which is essential to maintaining the normal operation of the device. Finally, the overall control of MMC-BESS applied in the grid-connected wind farm is given. Plenty of experimental results are obtained from a downscaled MMC-BESS prototype, which validate the effectiveness of the proposed control strategy.