Chen Xu

Dr. Chen Xu

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TYTianxiang Yin
Tianxiang Yin
CXChen Xu
Chen Xu
LLLei Lin
Lei Lin
KJKaiyuan Jing
Kaiyuan Jing
The utilization of silicon carbide (SiC) MOSFET instead of silicon (Si) IGBT can significantly improve the performance of many converters. However, modular multilevel converter (MMC) completely based on SiC MOSFET suffers from high cost and high conduction loss at high power levels. To solve these issues, a SiC MOSFET and Si IGBT hybrid MMC is proposed in this letter. In the new topology, only one full-bridge submodule (SM) of each arm uses SiC MOSFETs, while other half-bridge submodules use Si IGBTs. Meanwhile, a specialized modulation scheme is proposed to move most of the switching actions from Si SMs to the SiC SM. As a result, the advantages of SiC MOSFET and Si IGBT are both utilized, and the total loss and cost of the MMC is reduced. Finally, the experiment result proves the feasibility of the topology and modulation scheme, and the further loss analysis verifies the superiority of the hybrid MMC over others.

1 December 2016 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
CXChen Xu
Chen Xu
KDKe Dai
Ke Dai
XCXinwen Chen
Xinwen Chen
YKYong Kang
Yong Kang
Unbalanced voltage fluctuation at the point of common coupling (PCC) is a challenging power quality problem in power distribution system. This study presents an unbalanced PCC voltage regulation scheme with positive‐ and negative‐sequence control for modular multilevel converter (MMC) in medium‐voltage distribution static synchronous compensator (DSTATCOM) application. The proposed positive‐sequence control is utilised to regulate the positive‐sequence component of PCC voltage to rated value, while the negative‐sequence control aims to cancel out the negative‐sequence component of PCC voltage completely. Compensation commands whether in positive‐ or negative‐sequence control are generated from unbalanced PCC voltage without utilisation of unbalanced load currents. DC circulating currents transferring active power among three phases of MMC are also analysed to illustrate power balance issue resulting from negative‐sequence control. Then comparison of negative‐sequence compensation capacity between MMC and full‐bridge cascaded converter with delta‐connection is illustrated. Experiment results acquired from a downscaled 85 V/1.5 kVA apparatus validate the effectiveness of the proposed control scheme.

24 April 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
CXChen Xu
Chen Xu
KDKe Dai
Ke Dai
XCXinwen Chen
Xinwen Chen
LPLi Peng
Li Peng
YZYuxiao Zhang
Yuxiao Zhang
ZDZiwei Dai
Ziwei Dai
Due to capacitor elements and inductive line impedance in power system, parallel resonance could be triggered in the presence of harmonic currents from nonlinear load, whose frequency may shift resulting from intermittent switching of the capacitor devices. So it is difficult for shunt active power filter (SAPF) to damp parallel resonance. This paper investigates parallel resonance detection with square-wave current active injection and selective compensation control with closed-loop regulation of point of common coupling (PCC) voltage for SAPF. The principles of parallel resonance and its frequency detection are analyzed by means of equivalent circuit. Through injecting given square-wave current lasting for 0.5 s, SAPF could fast detect parallel resonance with the help of spectrum analysis of resonance power index. In order to improve power quality of both PCC voltage and grid current, SAPF is controlled to suppress specified harmonic currents from nonlinear load and selectively damp parallel resonance at the same time. In addition, ordinary proportional-integral plus advanced repetitive controller in parallel is used to improve current tracking performance. Experiment test results are provided to verify the validity of proposed detection and control methods.

31 July 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
LLLei Lin
Lei Lin
YLYizhe Lin
Yizhe Lin
CXChen Xu
Chen Xu
YCYu Chen
Yu Chen
Hybrid modular multilevel converter (MMC) with half-bridge sub-modules (HBSMs) and full-bridge sub-modules (FBSMs) is considered as a promising topology for high-voltage direct current (HVDC) system to deal with DC fault due to its negative output from FBSMs. In addition, the negative output from FBSMs can increase modulation index at steady state. With boosted modulation index, AC voltage can be enhanced and remain unchanged under decreased DC voltage. However, the characteristics of SM capacitor voltage fluctuation for such a hybrid MMC are different from that in traditional MMC since the impacts of FBSMs and HBSMs should be compromised. Then the SM capacitance design should adapt to the working condition. In this paper, the charging and discharging processes of capacitor in HBSMs and FBSMs are physically analyzed in detail with piecewise analysis method. Then the characteristics of capacitor voltage fluctuation in HBSMs and FBSMs are portrayed. Based on the characteristics, the runnable region for hybrid MMC is demonstrated, and the principles to obtain the maximum energy variation in both kinds of SMs are deduced. Furthermore, the quantitative design method of the SM capacitance is brought out. Experiments are implemented to verify the feasibility and validity of the proposed analysis and design method.

5 June 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CXChen Xu
Chen Xu
LLLei Lin
Lei Lin
TYTianxiang Yin
Tianxiang Yin
JHJiabing Hu
Jiabing Hu
The Phase-shifted-carrier (PSC) technique is preferred for multilevel converters in medium-voltage applications with low submodule (SM) number. This technique can elevate the equivalent switching frequency resulting in low total harmonic distortions. However, for half-/full-bridge hybrid modular multilevel converter (MMC) with boosted modulation index, the conventional PSC method is invalid due to the asymmetric voltage reference wave. The SM capacitor voltages deviate from the rated value and harmonics below equivalent switching frequency appear in the arm and equivalent AC voltages. This paper introduces an improved PSC technique with a capacitor sorting algorithm to overcome this problem. The negative part of the reference wave is turned over and then multiplied by a correction factor. The angular displacement for triangular carriers between the upper and lower arms is determined by the parity of the half-bridge number per arm. With the proposed method, the capacitor voltages are balanced and the AC voltage of MMC has the lowest harmonic distortion. Double-Fourier analysis for the proposed technique is carried out, and harmonic characteristics are revealed. The experimental results validate the correctness and feasibility of the improved PSC technique for hybrid MMC with boosted modulation index and asymmetric reference wave.

1 May 2017 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
XCXinwen Chen
Xinwen Chen
KDKe Dai
Ke Dai
CXChen Xu
Chen Xu
LPLi Peng
Li Peng
YZYuxiao Zhang
Yuxiao Zhang
Shunt active power filter (SAPF) is conventionally designed to compensate harmonic currents from non‐linear load. However, due to parallel resonance between line impedance and capacitive load, the distortion of the voltage at point of common coupling (PCC) and grid current may not be mitigated completely by traditional manner of SAPF. This paper investigates harmonic compensation and resonance damping combined control for SAPF with selective closed‐loop regulation of PCC voltage. Through developing equivalent circuit model, physical principle of SAPF with the proposed scheme is analysed as well as resonance frequency shifting phenomenon. To compensate specified harmonic currents, compensation reference is extracted flexibly by means of improved recursive discrete Fourier transform algorithm with phase‐angle compensation. Meanwhile, selective virtual conductance with proportional–integral (PI) regulation of PCC voltage is proposed to damp parallel resonance. Then, a zero steady‐state error controller composed of ordinary PI and advanced repetitive controller in parallel under synchronous rotation frame is adopted to improve current tracking performance of SAPF. Experimental results are provided to verify the effectiveness of the proposed method.