Yuxiao Zhang

Yuxiao Zhang

Auto-generated profile, based on publicly available information

Yuxiao Zhang

State Key Laboratory of Advanced Electromagnetic Engineering and Technology School of Electrical and Electronic Engineering Huazhong University of Science and Technology Wuhan People's Republic of China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2017 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
CXChen Xu
Chen Xu
KDKe Dai
Ke Dai
XCXinwen Chen
Xinwen Chen
LPLi Peng
Li Peng
YZYuxiao Zhang
Yuxiao Zhang
ZDZiwei Dai
Ziwei Dai
Due to capacitor elements and inductive line impedance in power system, parallel resonance could be triggered in the presence of harmonic currents from nonlinear load, whose frequency may shift resulting from intermittent switching of the capacitor devices. So it is difficult for shunt active power filter (SAPF) to damp parallel resonance. This paper investigates parallel resonance detection with square-wave current active injection and selective compensation control with closed-loop regulation of point of common coupling (PCC) voltage for SAPF. The principles of parallel resonance and its frequency detection are analyzed by means of equivalent circuit. Through injecting given square-wave current lasting for 0.5 s, SAPF could fast detect parallel resonance with the help of spectrum analysis of resonance power index. In order to improve power quality of both PCC voltage and grid current, SAPF is controlled to suppress specified harmonic currents from nonlinear load and selectively damp parallel resonance at the same time. In addition, ordinary proportional-integral plus advanced repetitive controller in parallel is used to improve current tracking performance. Experiment test results are provided to verify the validity of proposed detection and control methods.

28 September 2018 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YZYuxiao Zhang
Yuxiao Zhang
KDKe Dai
Ke Dai
XCXinwen Chen
Xinwen Chen
YKYong Kang
Yong Kang
ZDZiwei Dai
Ziwei Dai
This paper addresses the stability analysis of shunt active power filter (SAPF) with capacitive load for selective harmonic suppression and resonance damping. If the capacitive load current is measured as part of harmonic suppression current reference, the SAPF with conventional selective harmonic suppression would amplify the corresponding harmonic beyond resonance frequency. Previous studies could not clearly explain this harmonic amplification phenomenon without the selective harmonic extraction model in stability analysis. By viewing discrete Fourier transform (DFT) as cluster of band-pass filter (BPF), the modeling process is taken into consideration and is well simplified. The stability condition for suppressing and damping each selected harmonic can be easily estimated with the help of Nyquist stability criterion or root locus method in different SAPF control scenarios. To avoid the instability and compensate the harmonic current, a novel combined control strategy of SAPF is carried out to simultaneously suppress the harmonics whose frequencies are lower than the resonance frequency and mitigate the rest of harmonics by resonance damping method. Experiments have been performed to verify the effectiveness of the proposed strategy.

1 May 2017 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
XCXinwen Chen
Xinwen Chen
KDKe Dai
Ke Dai
CXChen Xu
Chen Xu
LPLi Peng
Li Peng
YZYuxiao Zhang
Yuxiao Zhang
Shunt active power filter (SAPF) is conventionally designed to compensate harmonic currents from non‐linear load. However, due to parallel resonance between line impedance and capacitive load, the distortion of the voltage at point of common coupling (PCC) and grid current may not be mitigated completely by traditional manner of SAPF. This paper investigates harmonic compensation and resonance damping combined control for SAPF with selective closed‐loop regulation of PCC voltage. Through developing equivalent circuit model, physical principle of SAPF with the proposed scheme is analysed as well as resonance frequency shifting phenomenon. To compensate specified harmonic currents, compensation reference is extracted flexibly by means of improved recursive discrete Fourier transform algorithm with phase‐angle compensation. Meanwhile, selective virtual conductance with proportional–integral (PI) regulation of PCC voltage is proposed to damp parallel resonance. Then, a zero steady‐state error controller composed of ordinary PI and advanced repetitive controller in parallel under synchronous rotation frame is adopted to improve current tracking performance of SAPF. Experimental results are provided to verify the effectiveness of the proposed method.

23 March 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
YZYuxiao Zhang
Yuxiao Zhang
KDKe Dai
Ke Dai
HXHongwei Xu
Hongwei Xu
TLTianyi Liu
Tianyi Liu
HLHaitao Lin
Haitao Lin
YKYong Kang
Yong Kang
In this paper, 100kHz sampling and switching frequency shunt active power filter (SAPF), which is based on a dual-core DSP TMS320F28377D, is designed for the potential market of high-frequency harmonic suppression in more electric aircraft (MEA) or high-speed train (HST). By utilizing the multithreading and multiprocessing method, the different computation segments, such as analog-to-digital conversion, recursive discrete Fourier transform (RDFT), inner-loop current and outer-loop voltage control, can be rearranged as several parallel operation groups. Compared to the traditional single pipeline structure of the mostly 10~20kHz switching frequency commercial SAPF, this parallel execution speeds up the signal processing so that the highly increased sampling frequency makes the current control loop reaches wider bandwidth even with simple PI regulator. Meanwhile, for wideband harmonic suppression, a multiresolution RDFT strategy is proposed to extend the range of the selected harmonic without sacrificing its extraction accuracy. After raising the sampling frequency to 100kHz, the proposed SAPF with much easier current controller could suppress wider frequency harmonics than other 10~20kHz SAPF. A 10kVA prototype with CREE SiC power module CCS050M12CM2 is set up to verify its effectiveness. The result complies with the IEEE standard 519-2014.

1 March 2017
Verified
Conference Paper
Closed access
YZYuxiao Zhang
Yuxiao Zhang
KDKe Dai
Ke Dai
XCXinwen Chen
Xinwen Chen
YKYong Kang
Yong Kang
ZDZiwei Dai
Ziwei Dai
This paper presents a hybrid compensation system with shunt active power filter(SAPF) and power capacitors. Firstly, two different load current detection points are introduced. With traditional method, hybrid compensation system is stable when capacitor current is not included in the detected load current. But, when capacitor current is included, the resonance frequency would be shifted to higher frequency which leads to SAPF self-oscillation and controller saturation. Then, an improved method that reversing part of SAPF controller current references whose spectra higher than resonance frequency is proposed. The objective of this improved method is to prevent SAPF out of control. However, harmonic mitigation is a welcome “by-product” which comes from this reversal of current reference. Terminal voltage is also detected for resonance damping which is helpful to mitigate harmonic distortion. At last, experiments results are presented to verify the proposed method.

6 June 2019 in IET Electric Power Applications
Verified
Journal Article
Open access
PDF file
YZYuxiao Zhang
Yuxiao Zhang
KDKe Dai
Ke Dai
CXChen Xu
Chen Xu
YKYong Kang
Yong Kang
ZDZiwei Dai
Ziwei Dai
The modular multilevel converter (MMC) is attractive for medium‐ and high‐power applications because of its high modularity, availability and power quality. In this study, a quadruple sampling phase‐shifted‐carrier pulse‐width modulation (PSC‐PWM) strategy based on hierarchical distributed control architecture for MMC in medium‐voltage power distribution static synchronous compensator (DSTATCOM) application is presented. Compared to centralised control architecture, the multi‐digital signal processors master–slave hierarchical control architecture can enhance the scalability of MMC‐DSTATCOM and the sub‐module (SM) number can expand without limitation. To take advantage of the proposed hierarchical architecture, the multiple sampling PSC‐PWM technique is employed to improve the converter performance. The spectrum of the electromotive force of MMC with quadruple sampling is almost the same as that of natural sampling, which leads to fewer harmonics in reactive and harmonic current compensating. Besides, it also raises the sampling frequency so that the MMC‐DSTATCOM can compensate harmonic at the low SM switching frequency. The effectivenesses of the proposed architecture and modulation method are verified by experimental results obtained from a 60 V/2 kVA downscaled prototype.