Laura Pol

Laura Pol

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2019 in Nanomaterials
Verified
Journal Article
Open access
PDF file
LPLaura Pol
Laura Pol
CEChris Eckstein
Chris Eckstein
LALaura K. Acosta
Laura K. Acosta
EXElisabet Xifre-Perez
Elisabet Xifre-Perez
Josep Ferré-BorrullJosep Ferré-Borrull
Josep Ferré-Borrull
Lluis F. MarsalLluis F. Marsal
Lluis F. Marsal
The chemical modification, or functionalization, of the surfaces of nanomaterials is a key step to achieve biosensors with the best sensitivity and selectivity. The surface modification of biosensors usually comprises several modification steps that have to be optimized. Real-time monitoring of all the reactions taking place during such modification steps can be a highly helpful tool for optimization. In this work, we propose nanoporous anodic alumina (NAA) functionalized with the streptavidin-biotin complex as a platform towards label-free biosensors. Using reflective interferometric spectroscopy (RIfS), the streptavidin-biotin complex formation, using biotinylated thrombin as a molecule model, was monitored in real-time. The study compared the performance of different NAA pore sizes in order to achieve the highest response. Furthermore, the optimal streptavidin concentration that enabled the efficient detection of the biotinylated thrombin attachment was estimated. Finally, the ability of the NAA-RIfS system to quantify the concentration of biotinylated thrombin was evaluated. This study provides an optimized characterization method to monitor the chemical reactions that take place during the biotinylated molecules attachment within the NAA pores.

1 October 2018 in Journal of Biological Engineering
Verified
Journal Article
Open access
PDF file
PFP. Formentín
P. Formentín
ÚCÚrsula Catalán
Úrsula Catalán
LPLaura Pol
Laura Pol
SFSara Fernández-Castillejo
Sara Fernández-Castillejo
RSRosa Solà
Rosa Solà
Lluis F. MarsalLluis F. Marsal
Lluis F. Marsal
The ability to direct the cellular response by means of biomaterial surface topography is important for biomedical applications. Substrate surface topography has been shown to be an effective cue for the regulation of cellular response. Here, the response of human aortic endothelial cells to nanoporous anodic alumina and macroporous silicon with collagen and fibronectin functionalization has been studied. Confocal microscopy and scanning electron microscopy were employed to analyse the effects of the material and the porosity on the adhesion, morphology, and proliferation of the cells. Cell spreading and filopodia formation on macro- and nanoporous material was characterized by atomic force microscopy. We have also studied the influence of the protein on the adhesion. It was obtained the best results when the material is functionalized with fibronectin, regarding cells adhesion, morphology, and proliferation. These results permit to obtain chemical modified 3D structures for several biotechnology applications such as tissue engineering, organ-on-chip or regenerative medicine.

19 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
LPLaura Pol
Laura Pol
LALaura Karen Acosta
Laura Karen Acosta
Josep Ferré-BorrullJosep Ferré-Borrull
Josep Ferré-Borrull
Lluis F. MarsalLluis F. Marsal
Lluis F. Marsal
Aptamer biosensors are one of the most powerful techniques in biosensing. Achieving the best platform to use in aptamer biosensors typically includes crucial chemical modifications that enable aptamer immobilization on the surface in the most efficient manner. These chemical modifications must be well defined. In this work we propose nanoporous anodic alumina (NAA) chemically modified with streptavidin as a platform for aptamer immobilization. The immobilization of biotinylated thrombin binding aptamer (TBA) was monitored in real time by means of reflective interferometric spectroscopy (RIfS). The study has permitted to characterize in real time the path to immobilize TBA on the inner pore walls of NAA. Furthermore, this study provides an accurate label-free method to detect thrombin in real-time with high affinity and specificity.

6 March 2018 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
CEChris Eckstein
Chris Eckstein
LALaura K. Acosta
Laura K. Acosta
LPLaura Pol
Laura Pol
EXElisabet Xifre-Perez
Elisabet Xifre-Perez
JPJosep Pallares
Josep Pallares
Lluis F. MarsalLluis F. Marsal
Lluis F. Marsal

24 January 2026 in Movement Disorders
Verified
Journal Article
Closed access
MTMoritz Thiel
Moritz Thiel
KBKaterina Bernardi
Katerina Bernardi
ESEnrique Gonzalez Saez‐Diez
Enrique Gonzalez Saez‐Diez
JRJoshua Rong
Joshua Rong
NDNathalie Dorison
Nathalie Dorison
DEDarius Ebrahimi-Fakhari
Darius Ebrahimi-Fakhari

30 May 2021 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
LPLaura Pol
Laura Pol
Josep Ferré-BorrullJosep Ferré-Borrull
Josep Ferré-Borrull
EXElisabet Xifre-Perez
Elisabet Xifre-Perez
JPJosep Pallares
Josep Pallares
Lluis F. MarsalLluis F. Marsal
Lluis F. Marsal
Nanoporous anodic alumina (NAA) is a material with a high interest in nanotechnology[1]. Its physical and chemical properties combined with a cost-effective and scalable production process make it a good candidate in many nanotechnologically-related applications. Its high and tuneable surface-to-volume ratio as well as its interesting optical properties[2] have been used as the basis of different biosensing schemes[3]. Biosensing, and specifically optical biosensing is of great interest in health and environmental applications. The reflection interference spectroscopy (RIfS) method based on NAA has demonstrated its ability in detecting many kinds of molecules (proteins, antibodies[4]). One of the molecular systems with interest in biotechnological applications is the streptavidin-biotin system. The high affinity between both molecules is exploited in many applications for the binding of different biological species. For this reason, we have studied the streptavidin-biotin binding event with NAA-based RIfS, as part of a biosensing process. In our study we assess the optimal conditions for real time monitoring of the different steps (covalent streptavidin bonding, surface passivation, biotin complexation). In order to establish such optimal conditions, we have chosen the protein thrombin as a model molecule to be detected. We prepared NAA with the usual anodization conditions under oxalic acid electrolyte to obtain porous layers with uniform pore diameter and with a thickness that permits the measurement with RIfS in a flow-cell where the different species in solution can be introduced. The experiments consisted of monitoring the change in effective optical thickness (EOT, the quantitative characteristic parameter obtained from RIfS) in the different steps of the biosensing process. The NAA pore surfaces were initially functionalized with (3-aminopropyl)triethoxysilane (APTES) with the carboxyl groups activated in order to form later a peptide bond with the streptavidin. One of the parameters to be optimized was the pore diameter. Furthermore, in order to study the ability of RIfS to detect the covalent streptavidin binding to the NAA pore surface, different concentrations of streptavidin were tested. Finally, the biosensing capabilities were evaluated by detecting biotinylated thrombin at different concentrations. An example of a complete experiment with all the steps in the streptavidin-biotinylated molecule attachment detection can be seen in Figure 1. After establishing a baseline with a PBS flow, streptavidin at 50 µg/ml is introduced in the RIfS setup and its covalent attachment to APTES is detected as an increase in EOT. Following this first step, PBS is introduced to wash away the non-specifically bound molecules and a 3% Bovine Serum Albumin (BSA) solution is flowed to passivate the remaining activated carboxyl groups of APTES and the remaining hydroxyl groups on the NAA pore surface. Such steps are detected by the RIfS procedure. Then, after a subsequent PBS wash, biotinylated thrombin at a concentration of 20 µg/ml is introduced causing a steady increase in EOT reaching a value of 3.5 nm above the initial one. The experiment in Figure 1 was repeated for different NAA pore sizes revealing a higher change in EOT for bigger pore sizes. An important parameter in the detection of the biotinylated molecules binding is the concentration at the streptavidin immobilization step. Thus, different streptavidin concentrations were tested in 60 nm pore diameter NAA. Results are summarized in Figure 2: for the highest concentrations (50 µg/ml) the attachment of streptavidin shows a two-phase curve with an initial phase with a faster increase in EOT and a second phase with a slower increase after an inflection point in the EOT versus time curve. Instead, for a small concentration (1 µg/ml) an initial fast increase is followed by a stabilization of the EOT signal. These two behaviors are associated with the attachment of streptavidin to the activated carboxyl of APTES for the initial fast EOT increase, while the subsequent slower increase can be explained by the aggregation of streptavidin through amine group binding. Finally, in order to demonstrate the capability of quantifying the attachment of biotinylated molecules to the NAA surface, the process was carried out using thrombin as the model molecule and for increasing concentrations. Figure 3 shows the change in EOT as a function of the thrombin concentration. It can be seen that RIfS based on NAA sensing platforms is able to quantify such attachment. [1] Josep Ferré-Borrull, et al., Nanomaterials, vol. 7, p. 5225 (2014). [2] Josep Ferré-Borrull et al., in NANOPOROUS ALUMINA: FABRICATION, STRUCTURE, PROPERTIES AND APPLICATIONS, Springer Series in Materials Science, vol. 219, p. 185 (2015). [3] Chris Eckstein, ACS Applied Materials and Interfaces, vol. 10, p.10571 (2018). [4] Gerard Macías, Analyst, vol. 140, p. 4848 (2015). Figure 1