2 February 2022 in IEEE Transactions on Smart Grid
Soft open points (SOPs) are power electronic devices that are usually placed at normally open points of electricity distribution networks to provide flexible power control to the networks. This paper gives a comprehensive overview of both academic research and industrial practice on SOPs in electricity distribution networks. The topologies of SOPs as multi-functional power electronic devices are identified and compared, which include back-to-back voltage source converters, multi-terminal voltage source converters, unified power flow controllers, and direct AC-to-AC modular multilevel converters. The academic research is reviewed in three aspects, i.e., benefit quantification, control, and optimal siting and sizing of SOPs. The benefit quantification indices are categorized into feeder load balancing, voltage profile improvement, power losses reduction, three-phase balancing and DG hosting capacity enhancement. The control of SOPs is summarized as a three-level control structure, where the system-level and converter-level control are further discussed. For optimal siting and sizing of SOPs, problem formulation and solution methods are analyzed. Besides the academic research, practical industrial projects of SOPs worldwide are also summarized. Finally, opportunities of research and industrial application of SOPs are discussed.
4 August 2021 in IEEE Transactions on Power Electronics
To enable fast and accurate models of SiC MOSFETs for transient simulation, a hybrid data-driven modeling methodology of SiC MOSFETs is proposed. Unlike conventional modeling methods that are based on complex nonlinear equations, data-driven artificial neural networks (ANNs) are used in this article. For model accuracy, the $I$ – $V$ characteristics are measured in the whole operation region to train the ANN. The ANN model is then combined with behavior-based equations to model the cutoff region and to avoid overfitting the ANN. In addition, the $C$ – $V$ characteristics are modeled by ANNs with a logarithmic scale for accuracy. The proposed model is implemented and simulated in SPICE simulator SIMetrix. The simulation results are compared with experimental results from a double pulse tester to validate the proposed modeling methodology. The model is also compared with the Angelov model created by the Keysight MOSFET modeling software. The comparison results show that the proposed model is more accurate than the Angelov model. Besides, when compared to the Angelov model, the proposed model requires 30% less computation time when simulating a double pulse tester. In addition, the proposed modeling method also has better adaptability to model different types of SiC MOSFETs.
24 December 2021 in IEEE Transactions on Transportation Electrification
An electric vehicle (EV) charger can operate in an autonomous mode to create its own grid by utilizing the EV batteries during grid blackouts. This requires three-phase four-wire inverters as the grid-side ac/dc port of the EV charger to supply unbalanced loads. Although silicon carbide (SiC) metal–oxide–semiconductor field-effect transistors (MOSFETs) can be adopted to increase the power density of these inverters, the second-order ripples exhibited on the dc bus caused by unbalanced loads need to be mitigated by a large dc capacitance—increasing the size of inverters. In this article, an improved neutral leg for three-phase four-wire inverters is presented, which not only provides the neutral current for unbalanced loads, such as a conventional neutral leg, but also reduces the second-order ripples on the dc bus without the need for additional hardware components. Furthermore, it can reduce by 50% the dc capacitance compared to its conventional counterpart. A control strategy featuring power decoupling capability is included for the improved leg. It was built with SiC MOSFETs and experimentally assessed with a three-phase inverter, with results verifying its effectiveness. For completeness, the performance of the improved neutral leg is also evaluated through simulations in PLECS and compared to a conventional neutral leg.