Antonio IULA

Prof. Antonio IULA

University of Basilicata, Potenza, Basilicata, Italy
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2002 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
ACA. Caronti
A. Caronti
Giosue CalianoGiosue Caliano
Giosue Caliano
Antonio IULAAntonio IULA
Antonio IULA
MPM. Pappalardo
M. Pappalardo
Modeling of capacitive micromachined ultrasonic transducers (cMUTs) is based on a two-port network with an electrical and a mechanical side. To obtain a distributed model, a solution of the differential equation of motion of the diaphragm for each element of the transducer has to be found. Previous works omit the mechanical load of the cavity behind the diaphragm, i.e., the effect of the gas inside. In this paper, we propose a distributed model for cMUTs that takes this effect into account. A closed-form solution of the mechanical impedance of the membranes has been obtained, including the effect of the restoring forces because of the stiffness of the membrane and because of the compression of the air in the cavity. Simulation results based on the presented model are compared with the experimental data for two types of cMUTs reported in the recent literature. It is demonstrated that the compression of the air has a significant effect on the fundamental frequency of the air transducer, with a deviation of about 22% from the prediction of a model that does not consider the interaction between the vibrating diaphragm and the air cushion.

27 December 2005 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Giosue CalianoGiosue Caliano
Giosue Caliano
Riccardo CarotenutoRiccardo Carotenuto
Riccardo Carotenuto
ECE. Cianci
E. Cianci
VFV. Foglietti
V. Foglietti
ACA. Caronti
A. Caronti
MPM. Pappalardo
M. Pappalardo
In this paper we report the design, fabrication process, and characterization of a 64-elements capacitive micromachined ultrasonic transducer (cMUT), 3 MHz center frequency, 100% fractional bandwidth. Using this transducer, we developed a linear probe for application in medical echographic imaging. The probe was fully characterized and tested with a commercial echographic scanner to obtain first images from phantoms and in vivo human body. The results, which quickly follow similar results obtained by other researchers, clearly show the great potentiality of this new emerging technology. The cMUT probe works better than the standard piezoelectric probe as far as the axial resolution is concerned, but it suffers from low sensitivity. At present this can be a limit, especially for in depth operation. But we are strongly confident that significant improvements can be obtained in the very near future to overcome this limitation, with a better transducer design, the use of an acoustic lens, and using well matched, front-end electronics between the transducer and the echographic system.

7 August 2006 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Antonio IULAAntonio IULA
Antonio IULA
MPMassimo Pappalardo
Massimo Pappalardo
In the present work, a traveling wave ultrasonic motor (TWUSM) is proposed. It is composed of an annular-shaped stator and two cone-shaped rotors that are pressed in contact to the borders of the inner surface of the stator. A rotating traveling wave has been generated in the stator by using as vibration generators two bolted Langevin transducers (BLT) opportunely shifted in space and in time. The vibrational behavior of the stator as well as the traveling wave generation has been simulated with the finite-element method (FEM) software. A prototype of the motor has been manufactured and experimentally characterized. It exhibits a static torque of about 0.8 N·m and a maximum angular speed of about 300 rpm. Possible variations of the present design aimed to increase output torque or minimize encumbrance are described and discussed.

1 May 2002 in Ultrasonics
Verified
Journal Article
Closed access
Antonio IULAAntonio IULA
Antonio IULA
FVFernando Vazquez
Fernando Vazquez
MPMassimo Pappalardo
Massimo Pappalardo
JGJuan A. Gallego
Juan A. Gallego

1 December 2011 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
NLNicola Lamberti
Nicola Lamberti
Giosue CalianoGiosue Caliano
Giosue Caliano
Antonio IULAAntonio IULA
Antonio IULA
Alessandro Stuart SavoiaAlessandro Stuart Savoia
Alessandro Stuart Savoia

20 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Antonio IULAAntonio IULA
Antonio IULA
Biometric recognition systems are finding applications in more and more civilian fields because they proved to be reliable and accurate. Among the other technologies, ultrasound has the main merit of acquiring 3D images, which allows it to provide more distinctive features and gives it a high resistance to spoof attacks. This work reviews main research activities devoted to the study and development of ultrasound sensors and systems for biometric recognition purposes. Several transducer technologies and different ultrasound techniques have been experimented on for imaging biometric characteristics like fingerprints, hand vein pattern, palmprint, and hand geometry. In the paper, basic concepts on ultrasound imaging techniques and technologies are briefly recalled and, subsequently, research studies are classified according to the kind of technique used for collecting the ultrasound image. Overall, the overview demonstrates that ultrasound may compete with other technologies in the expanding market of biometrics, as the different commercial fingerprint sensors integrated in portable electronic devices like smartphones or tablets demonstrate.