Resistive switching memory (RRAM) based on the redox-induced conductivity change in some metal oxides attracts considerable interest as a new technology for next-generation nonvolatile electronic storage. Although resistance-switching phenomena in several transition metal oxides have been known from decades, the details of the switching mechanisms and the nature of the different resistive states are still largely debated. For nonvolatile memory applications, the scaling potential of RRAMs is the most relevant issue, and understanding the scaling capability of RRAM devices requires a sound interpretation of resistance-switching operation and reliability aspects. This work addresses the scaling dependence of RRAM switching parameters. The dependence on the electrode area and on the size of the conductive filament (CF) responsible for low-resistance memory state is investigated. The RRAM conduction modes depending on CF size are discussed based on temperature dependent resistance analysis. Reset characteristics in different resistance states are explained by a Joule heating model for CF oxidation.
The process of the formation and disruption of nanometric conductive filaments in a HfO2/TiN structure is investigated by conductive atomic force microscopy. The preforming state evidences nonhomogeneous conduction at high fields through conductive paths, which are associated with pre-existing defects and develop into conductive filaments with a forming procedure. The disruption of the same filaments is demonstrated as well, according to a bipolar operation. In addition, the conductive tip of the microscopy is exploited to perform electrical operations on single conductive spots, which evidences that neighboring conductive filaments are not electrically independent. We propose a picture that describes the evolution of the shape of the conductive filaments in the processes of their formation and disruption, which involves the development of conductive branches from a common root; this root resides in the pre-existing defects that lay at the HfO2/TiN interface.
27 December 2005 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
In this paper we report the design, fabrication process, and characterization of a 64-elements capacitive micromachined ultrasonic transducer (cMUT), 3 MHz center frequency, 100% fractional bandwidth. Using this transducer, we developed a linear probe for application in medical echographic imaging. The probe was fully characterized and tested with a commercial echographic scanner to obtain first images from phantoms and in vivo human body. The results, which quickly follow similar results obtained by other researchers, clearly show the great potentiality of this new emerging technology. The cMUT probe works better than the standard piezoelectric probe as far as the axial resolution is concerned, but it suffers from low sensitivity. At present this can be a limit, especially for in depth operation. But we are strongly confident that significant improvements can be obtained in the very near future to overcome this limitation, with a better transducer design, the use of an acoustic lens, and using well matched, front-end electronics between the transducer and the echographic system.