Giosue Caliano

Prof. Giosue Caliano

Dept. of Engineering, University Roma Tre, Roma, Italy
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2014 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
Giulia MatroneGiulia Matrone
Giulia Matrone
Alessandro Stuart SavoiaAlessandro Stuart Savoia
Alessandro Stuart Savoia
Giosue CalianoGiosue Caliano
Giosue Caliano
GMGiovanni Magenes
Giovanni Magenes
Most of ultrasound medical imaging systems currently on the market implement standard Delay and Sum (DAS) beamforming to form B-mode images. However, image resolution and contrast achievable with DAS are limited by the aperture size and by the operating frequency. For this reason, different beamformers have been presented in the literature that are mainly based on adaptive algorithms, which allow achieving higher performance at the cost of an increased computational complexity. In this paper, we propose the use of an alternative nonlinear beamforming algorithm for medical ultrasound imaging, which is called Delay Multiply and Sum (DMAS) and that was originally conceived for a RADAR microwave system for breast cancer detection. We modify the DMAS beamformer and test its performance on both simulated and experimentally collected linear-scan data, by comparing the Point Spread Functions, beampatterns, synthetic phantom and in vivo carotid artery images obtained with standard DAS and with the proposed algorithm. Results show that the DMAS beamformer outperforms DAS in both simulated and experimental trials and that the main improvement brought about by this new method is a significantly higher contrast resolution (i.e., narrower main lobe and lower side lobes), which turns out into an increased dynamic range and better quality of B-mode images.

15 June 2012 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Alessandro Stuart SavoiaAlessandro Stuart Savoia
Alessandro Stuart Savoia
Giosue CalianoGiosue Caliano
Giosue Caliano
MPMassimo Pappalardo
Massimo Pappalardo
Medical ultrasonography is a powerful and costeffective diagnostic technique. To date, high-end medical imaging systems are able to efficiently implement real-time image formation techniques that can dramatically improve the diagnostic capabilities of ultrasound. Highly performing and thermally efficient ultrasound probes are then required to successfully enable the most advanced techniques. In this context, ultrasound transducer technology is the current limiting factor. Capacitive micromachined ultrasonic transducers (CMUTs) are micro-electro-mechanical systems (MEMS)-based devices that have been widely recognized as a valuable alternative to piezoelectric transducer technology in a variety of medical imaging applications. Wideband operation, good thermal efficiency, and low fabrication cost, especially for those applications requiring high-volume production of small-area dice, are strength factors that may justify the adoption of this MEMS technology in the medical ultrasound imaging field. This paper presents the design, development, fabrication, and characterization of a 12-MHz ultrasound probe for medical imaging, based on a CMUT array. The CMUT array is microfabricated and packed using a novel fabrication concept specifically conceived for imaging transducer arrays. The performance of the developed probe is optimized by including analog front-end reception electronics. Characterization and imaging results are used to assess the performance of CMUTs with respect to conventional piezoelectric transducers.

1 August 2006 in Microelectronics Journal
Verified
Journal Article
Closed access
ACAlessandro Caronti
Alessandro Caronti
Giosue CalianoGiosue Caliano
Giosue Caliano
Riccardo CarotenutoRiccardo Carotenuto
Riccardo Carotenuto
Alessandro Stuart SavoiaAlessandro Stuart Savoia
Alessandro Stuart Savoia
MPM. Pappalardo
M. Pappalardo
VFV. Foglietti
V. Foglietti

7 August 2002 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
ACA. Caronti
A. Caronti
Giosue CalianoGiosue Caliano
Giosue Caliano
Antonio IULAAntonio IULA
Antonio IULA
MPM. Pappalardo
M. Pappalardo
Modeling of capacitive micromachined ultrasonic transducers (cMUTs) is based on a two-port network with an electrical and a mechanical side. To obtain a distributed model, a solution of the differential equation of motion of the diaphragm for each element of the transducer has to be found. Previous works omit the mechanical load of the cavity behind the diaphragm, i.e., the effect of the gas inside. In this paper, we propose a distributed model for cMUTs that takes this effect into account. A closed-form solution of the mechanical impedance of the membranes has been obtained, including the effect of the restoring forces because of the stiffness of the membrane and because of the compression of the air in the cavity. Simulation results based on the presented model are compared with the experimental data for two types of cMUTs reported in the recent literature. It is demonstrated that the compression of the air has a significant effect on the fundamental frequency of the air transducer, with a deviation of about 22% from the prediction of a model that does not consider the interaction between the vibrating diaphragm and the air cushion.

27 December 2005 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Giosue CalianoGiosue Caliano
Giosue Caliano
Riccardo CarotenutoRiccardo Carotenuto
Riccardo Carotenuto
ECE. Cianci
E. Cianci
VFV. Foglietti
V. Foglietti
ACA. Caronti
A. Caronti
MPM. Pappalardo
M. Pappalardo
In this paper we report the design, fabrication process, and characterization of a 64-elements capacitive micromachined ultrasonic transducer (cMUT), 3 MHz center frequency, 100% fractional bandwidth. Using this transducer, we developed a linear probe for application in medical echographic imaging. The probe was fully characterized and tested with a commercial echographic scanner to obtain first images from phantoms and in vivo human body. The results, which quickly follow similar results obtained by other researchers, clearly show the great potentiality of this new emerging technology. The cMUT probe works better than the standard piezoelectric probe as far as the axial resolution is concerned, but it suffers from low sensitivity. At present this can be a limit, especially for in depth operation. But we are strongly confident that significant improvements can be obtained in the very near future to overcome this limitation, with a better transducer design, the use of an acoustic lens, and using well matched, front-end electronics between the transducer and the echographic system.

1 December 2017 in Photoacoustics
Verified
Journal Article
Open access
MVMaëva Vallet
Maëva Vallet
FVFrançois Varray
François Varray
JBJerome Boutet
Jerome Boutet
JDJean-Marc Dinten
Jean-Marc Dinten
Giosue CalianoGiosue Caliano
Giosue Caliano
DVDidier Vray
Didier Vray
Photoacoustic (PA) signals are short ultrasound (US) pulses typically characterized by a single-cycle shape, often referred to as N-shape. The spectral content of such wideband signals ranges from a few hundred kilohertz to several tens of megahertz. Typical reception frequency responses of classical piezoelectric US imaging transducers, based on PZT technology, are not sufficiently broadband to fully preserve the entire information contained in PA signals, which are then filtered, thus limiting PA imaging performance. Capacitive micromachined ultrasonic transducers (CMUT) are rapidly emerging as a valid alternative to conventional PZT transducers in several medical ultrasound imaging applications. As compared to PZT transducers, CMUTs exhibit both higher sensitivity and significantly broader frequency response in reception, making their use attractive in PA imaging applications. This paper explores the advantages of the CMUT larger bandwidth in PA imaging by carrying out an experimental comparative study using various CMUT and PZT probes from different research laboratories and manufacturers. PA acquisitions are performed on a suture wire and on several home-made bimodal phantoms with both PZT and CMUT probes. Three criteria, based on the evaluation of pure receive impulse response, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) respectively, have been used for a quantitative comparison of imaging results. The measured fractional bandwidths of the CMUT arrays are larger compared to PZT probes. Moreover, both SNR and CNR are enhanced by at least 6 dB with CMUT technology. This work highlights the potential of CMUT technology for PA imaging through qualitative and quantitative parameters.