Hybrid sorption-compression systems are gaining interest for heating/cooling/ refrigeration purposes in different applications, since they allow exploiting the benefits of both technologies and a better utilization of renewable sources. However, design of such components is still difficult, due to the intrinsic complexity of the systems and the lack of reliable models. In particular, the combination of adsorption-compression cascade unit has not been widely explored yet and there are no simulations or sizing tools reported in the literature. In this context, the present paper describes a model of a hybrid adsorption-compression system, realised in Modelica language using the commercial software Dymola. The models of the main components of the sorption and vapour compression unit are described in details and their validation presented. In addition, the integrated model is used for proving the feasibility of the system under dynamic realistic conditions and an example of the technical sizing that the model is able to accomplish is given.
The need for innovative heating and cooling systems to decarbonize the building sector is widely recognized. It is especially important to increase the share of renewables at building level by maximizing self-consumption and reducing the primary energy demand. Accordingly, in the present paper, the results on a wide experimental campaign on a hybrid system are discussed. The system included a sorption module working as the topping cycle in a cascade configuration with a DC-driven vapor compression heat pump. A three-fluids heat exchanger with a phase change material (PCM), i.e., RT4 with nominal melting temperature of 4 °C, was installed on the evaporator side of the heat pump, for simultaneous operation as thermal storage and heat pumping purposes. The heat pump was connected to a DC-bus that included PV connection and electricity storage (batteries). Results showed that the energy efficiency of the heat pump in cascade operation was double compared to compression-only configuration and that, when simultaneously charging and discharging the latent storage in cascade configuration, no penalization in terms of efficiency compared to the compression-only configuration was measured. The self-sufficiency of the system was evaluated for three reference weeks in summer conditions of Athens climate and it was found that up to 100% of the electricity needed to drive the system could be self-produced for a modest cooling demand and up to 67% for the warmer conditions with high cooling demand.
Ejector-based cooling systems have gathered scientific interest as a low-cost alternative for solar-assisted cooling applications, especially in regions with solar abundance. This work presents the experimental investigation of a solar ejector cooling prototype system. The system, developed at the National Technical University of Athens, includes a custom-made ejector and is powered by a 48 m2 flat plate solar collector field, assisted by an auxiliary natural gas boiler. Experimental testing under varying operating conditions was conducted to assess the system’s performance, focusing on the influence of evaporation and condensation temperatures. The maximum coefficient of performance (COP) was measured at approximately 0.160–0.165, corresponding to an entrainment ratio of 0.19 at an evaporation temperature of 9 °C and condensation temperatures of 26–27 °C. Ejector performance substantially declined with increased condensation temperatures. However, the influence of the evaporator pressure on system performance was less significant. These findings demonstrate the feasibility of ejector-based solar cooling as a sustainable solution for reducing electricity use in cooling applications, highlighting the critical influence of operating parameters in the system’s performance optimization.
This study regards the evaluation of the performance of a thermally stratified tank as an intermediate combi-storage tank for a solar-driven residential thermal system coupled to a seasonal energy storage system. In such applications, the efficient operation of this intermediate tank is crucial to the enhanced exploitation of the harvested solar energy and the minimization of heat losses. In this perspective, the development of a dedicated model in TRNSYS software and its validation with experimental results are investigated. With respect to the simulation model’s discretization, it was found that beyond 60 nodes, the benefits to the model’s accuracy are almost negligible. Comparing the experimental data with the simulation’s results, the predicted temperature profile converges accurately to the measured values under steady-state conditions (threshold stabilization period of 1000 s after charging/discharging has occurred). However, the response of the model deviates considerably under transient conditions due to the lack of detailed inertia modeling of both the tank and the rest of the system components. Conclusively, the developed 1D simulation model is adequate for on- and off-design models where transient phenomena are of reduced importance, whereas for dynamic and semi-dynamic simulations, more detailed models are needed.