Qimei Zhang

Dr. Qimei Zhang

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

24 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
CAChalani Abeywardena
Chalani Abeywardena
FVFrederique Vanheusden
Frederique Vanheusden
KWKate F. Walker
Kate F. Walker
RARICHARD ARM
RICHARD ARM
QZQimei Zhang
Qimei Zhang
Daily fetal movement counting based on maternal perception is widely deployed to monitor fetal wellbeing. However, the counting performed by the mother is prone to errors for various reasons. There are limited devices on the market that can provide reliable and automatic counting. This paper presents a prototype of a novel fetal movement monitoring device based on fibre Bragg grating sensors. Deformation of the skin caused by a fetal movement can lead to a change of the strain and stress on the optical fibre sensors, therefore can induce distortions to the breathing pattern of the mother. In the study data was gathered by the sensors through strain measurement and was post-processed using independent component analysis (ICA) and high-pass filtering to show the instances of the fetal movements. Information gathered during user trials with the prototype suggests that the system detects significantly higher numbers of fetus movements than that observed based on the mother’s perception. Among the various techniques available for fetal movement monitoring, fibre optic sensing provides many advantages including multiplex capability, flexibility and minimal size, making the concept an attractive solution for reliable monitoring of antenatal fetal movements.

24 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JBJames Alexander Bradbury
James Alexander Bradbury
QZQimei Zhang
Qimei Zhang
FLFrancisco U. Hernandez Ledezma
Francisco U. Hernandez Ledezma
RCRicardo Correia
Ricardo Correia
Sergiy KorposhSergiy Korposh
Sergiy Korposh
SMStephen Morgan
Stephen Morgan
Compression therapy is widely used as the gold standard for management of chronic venous insufficiency and venous leg ulcers, and the amount of pressure applied during the compression therapy is crucial in supporting healing. A fibre optic pressure sensor using Fibre Bragg Gratings (FBGs) is developed in this paper to measure sub-bandage pressure whilst removing cross-sensitivity due to strain in the fibre and temperature. The interface pressure is measured by an FBG encapsulated in a polymer and housed in a textile to minimise discomfort for the patient. The repeatability of a manual fabrication process is investigated by fabricating and calibrating ten sensors. A customized calibration setup consisting of a programmable translation stage and a weighing scale gives sensitivities in the range 0.4–1.5 pm/mmHg (2.6–11.3 pm/kPa). An alternative calibration method using a rigid plastic cylinder and a blood pressure cuff is also demonstrated. Investigations are performed with the sensor under a compression bandage on a phantom leg to test the response of the sensor to changing pressures in static situations. Measurements are taken on a human subject to demonstrate changes in interface pressure under a compression bandage during motion to mimic a clinical application. These results are compared to the current gold standard medical sensor using a Bland–Altman analysis, with a median bias ranging from −4.6 to −20.4 mmHg, upper limit of agreement (LOA) from −13.5 to 2.7 mmHg and lower LOA from −32.4 to −7.7 mmHg. The sensor has the potential to be used as a training tool for nurses and can be left in situ to monitor bandage pressure during compression therapy.

19 February 2015 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
QZQimei Zhang
Qimei Zhang
MMMelissa L. Mather
Melissa L. Mather
SMStephen Morgan
Stephen Morgan
Objective: A hybrid imaging technique, ultrasound-modulated luminescence tomography, that uses ultrasound to modulate diffusely propagating light has been shown to improve the spatial resolution of optical images. This paper investigates the underlying modulation mechanisms and the feasibility of applying this technique to improve spatial resolution in bioluminescence tomography. Methods: Ultrasound-modulated bioluminescence tomography was studied numerically to identify the effects of four factors (reduced optical scattering coefficient, optical absorption coefficient, refractive index, and luciferase concentration) on the depth of light modulation. In practice, an open source finite-element method tool for simulation of diffusely propagating light, near infrared fluorescence and spectral tomography, was modified to incorporate the effects of ultrasound modulation. The signal-to-noise ratios of detected modulated bioluminescent emissions are calculated using the optical and physical properties of a mouse model. Results: The modulation depth of the bioluminescent emission affected by the US induced variation of local concentration of the light emitting enzyme luciferase was at least two orders of magnitude greater than that caused by variations in the other factors. For surface radiances above approximately 107 photons/s/cm2/sr, the corresponding SNRs are detectable with the currently available detector technologies. Conclusion: The dominant effect in generation of ultrasound-modulated bioluminescence is ultrasound induced variation in luciferase concentration. The SNR analysis confirms the feasibility of applying ultrasound-modulated bioluminescence tomography in preclinical imaging of mice. Significance: The simulation model developed suggests ultrasound-modulated bioluminescence tomography is a potential technique to improve the spatial resolution of bioluminescence tomography.

24 October 2019 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
QZQimei Zhang
Qimei Zhang
AGAnna M. Grabowska
Anna M. Grabowska
PCphilip clarke
philip clarke
SMStephen Morgan
Stephen Morgan
The spatial resolution and light detected in fluorescence imaging for small animals are limited by light scattering, absorption and autofluorescence. To address this, novel near-infrared fluorescent contrast agents and imaging configurations have been investigated. In this paper, the influence of the light wavelength and imaging configurations (full-field illumination system and scanning system) on fluorescence imaging are compared quantitatively. The surface radiance for both systems is calculated by modifying the simulation tool Near-Infrared Fluorescence and Spectral Tomography. Fluorescent targets are embedded within a scattering medium at different positions. The surface radiance and spatial resolution are obtained for emission wavelengths between 620 nm and 1000 nm. It was found that the spatial resolution of the scanning system is independent of the tissue optical properties, whereas for full-field illumination, the spatial resolution degrades at longer wavelength. The full width at half maximum obtained by the scanning system is 25% lower than that obtained by the full-field illumination system when the targets are located in the middle of the phantom. The results indicate that although imaging at near-infrared wavelength can achieve a higher surface radiance, it may produce worse spatial resolution.

28 July 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
QZQimei Zhang
Qimei Zhang
SMStephen Morgan
Stephen Morgan
POPaul O’sHea
Paul O’sHea
MMMelissa L. Mather
Melissa L. Mather
A new imaging contrast agent is reported that provides an increased fluorescent signal upon application of ultrasound (US). Liposomes containing lipids labelled with pyrene were optically excited and the excimer fluorescence emission intensity was detected in the absence and presence of an ultrasound field using an acousto-fluorescence setup. The acousto-fluorescence dynamics of liposomes containing lipids with pyrene labelled on the fatty acid tail group (PyPC) and the head group (PyPE) were compared. An increase in excimer emission intensity following exposure to US was observed for both cases studied. The increased intensity and time constants were found to be different for the PyPC and PyPE systems, and dependent on the applied US pressure and exposure time. The greatest change in fluorescence intensity (130%) and smallest rise time constant (0.33 s) are achieved through the use of PyPC labelled liposomes. The mechanism underlying the observed increase of the excimer emission intensity in PyPC labelled liposomes is proposed to arise from the “wagging” of acyl chains which involves fast response and requires lower US pressure. This is accompanied by increased lipid lateral diffusivity at higher ultrasound pressures, a mechanism that is also active in the PyPE labelled liposomes.