Samer Mabrouk

Samer Mabrouk


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
CTCaitlin N. Teague
Caitlin N. Teague
JHJ. Alex Heller
J. Alex Heller
BNBrandi N. Nevius
Brandi N. Nevius
ACAndrew M. Carek
Andrew M. Carek
SMSamer Mabrouk
Samer Mabrouk
MEMozziyar Etemadi
Mozziyar Etemadi
Objective: We designed and validated a wearable, multimodal sensor brace for knee joint health assessment. Methods: An embedded-, two-microcontroller-based approach is used to sample high-throughput, multi-microphone joint acoustics (46.785 kHz) as well as lower-rate electrical bioimpedance (EBI) (1/46.17 s), inertial (100 – 250 Hz), and skin temperature (1 Hz) data, and these data are saved onto microSD cards. Additionally, a flexible, 3D-printed brace houses the custom circuit boards and sensors to enable wearable sensing. Results: The system achieves 9 hours of continuous joint sound recording, while the EBI, inertial, and temperature sensors can sample for 35 hours using 500 mAh batteries. Further, for the entirety of these continuous recordings, there were no dropped samples for any of the sensors. Lastly, proof-of-concept measurements were used to show the system’s efficacy for recording joint sounds and swelling data. Conclusion: This is, to the best of our knowledge, the first, completely untethered wearable system for multimodal knee health monitoring. Significance: The proposed smart brace may facilitate in-clinic or at-home measurements for joint health assessment.

10 July 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SMSamer Mabrouk
Samer Mabrouk
SHSinan Hersek
Sinan Hersek
HJHyeon Ki Jeong
Hyeon Ki Jeong
DWDaniel Whittingslow
Daniel Whittingslow
VGVenu G. Ganti
Venu G. Ganti
OIOmer Inan
Omer Inan
Objective: We present a robust methodology for tracking ankle edema longitudinally based on bioimpedance spectroscopy (BIS). Methods: We designed a miniaturized BIS measurement system and employed a novel calibration method that enables accurate, high-resolution measurements with substantially lower power consumption than conventional approaches. Using this state-of-the-art wearable BIS measurement system, we developed a differential measurement technique for robust assessment of ankle edema. This technique addresses many of the major challenges in longitudinal BIS-based edema assessment, including day-to-day variability in electrode placement, positional/postural variability, and intersubject variability. Results: We first evaluated the hardware in bench-top testing, and determined the error of the bioimpedance measurements to be 0.4 Ω for the real components and 0.54 Ω for the imaginary components with a resolution of 0.2 Ω. We then validated the hardware and differential measurement technique in: 1) an ex vivo, fresh-frozen, cadaveric limb model, and 2) a cohort of 11 human subjects for proof of concept (eight healthy controls and five subjects with recently acquired acute unilateral ankle injury). Conclusion: The hardware design, with novel calibration methodology, and differential measurement technique can potentially enable long-term quantification of ankle edema throughout the course of rehabilitation following acute ankle injuries. Significance: This could lead to better-informed decision making regarding readiness to return to activities and/or tailoring of rehabilitation activities to an individual's changing needs.

2 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JSJesus Antonio Sanchez-Perez
Jesus Antonio Sanchez-Perez
JBJohn Berkebile
John Berkebile
BNBrandi N. Nevius
Brandi N. Nevius
GOGoktug Ozmen
Goktug Ozmen
CNChristopher J. Nichols
Christopher J. Nichols
OIOmer Inan
Omer Inan
Heart failure (HF) exacerbations, characterized by pulmonary congestion and breathlessness, require frequent hospitalizations, often resulting in poor outcomes. Current methods for tracking lung fluid and respiratory distress are unable to produce continuous, holistic measures of cardiopulmonary health. We present a multimodal sensing system that captures bioimpedance spectroscopy (BIS), multi-channel lung sounds from four contact microphones, multi-frequency impedance pneumography (IP), temperature, and kinematics to track changes in cardiopulmonary status. We first validated the system on healthy subjects (n = 10) and then conducted a feasibility study on patients (n = 14) with HF in clinical settings. Three measurements were taken throughout the course of hospitalization, and parameters relevant to lung fluid status—the ratio of the resistances at 5 kHz to those at 150 kHz (K)—and respiratory timings (e.g., respiratory rate) were extracted. We found a statistically significant increase in K (p < 0.05) from admission to discharge and observed respiratory timings in physiologically plausible ranges. The IP-derived respiratory signals and lung sounds were sensitive enough to detect abnormal respiratory patterns (Cheyne–Stokes) and inspiratory crackles from patient recordings, respectively. We demonstrated that the proposed system is suitable for detecting changes in pulmonary fluid status and capturing high-quality respiratory signals and lung sounds in a clinical setting.

19 May 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
JBJohn Berkebile
John Berkebile
SMSamer Mabrouk
Samer Mabrouk
VGVenu G. Ganti
Venu G. Ganti
ASAdith V. Srivatsa
Adith V. Srivatsa
JSJesus Antonio Sanchez-Perez
Jesus Antonio Sanchez-Perez
OIOmer Inan
Omer Inan
Objective: Evaluating convenient, wearable multi-frequency impedance pneumography (IP)-based respiratory monitoring in ambulatory persons with novel electrode positioning. Methods: A wearable multi-frequency IP system was utilized to estimate tidal volume (TV) and respiratory timings in 14 healthy subjects. A 5.1 cm × 5.1 cm tetrapolar electrode array, affixed to the sternum, and a conventional thoracic electrode configuration were employed to measure the respective IP signals, patch and thoracic IP. Data collected during static postures—sitting and supine—and activities—walking and stair-stepping—were evaluated against a simultaneously-obtained spirometer (SP) volume signal. Results: Across all measurements, estimated TV obtained from the patch and thoracic IP maintained a Pearson correlation coefficient ( r ) of 0.93 $ \pm $ 0.05 and 0.95 $ \pm $ 0.05 to the ground truth TV, respectively, with an associated root-mean-square error (RMSE) of 0.177 L and 0.129 L, respectively. Average respiration rates (RRs) were extracted from 30-second segments with mean-absolute-percentage errors (MAPEs) of 0.93% and 0.74% for patch and thoracic IP, respectively. Likewise, average inspiratory and expiratory timings were identified with MAPEs less than 6% and 4.5% for patch and thoracic IP, respectively. Conclusion: We demonstrated that patch IP performs comparably to traditional, cumbersome IP configurations. We also present for the first time, to the best of our knowledge, that IP can robustly estimate breath-by-breath TV and respiratory timings during ambulation. Significance: This work represents a notable step towards pervasive wearable ambulatory respiratory monitoring via the fusion of a compact chest-worn form factor and multi-frequency IP that can be readily adapted for holistic cardiopulmonary monitoring.

18 March 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
SMSamer Mabrouk
Samer Mabrouk
DWDaniel Whittingslow
Daniel Whittingslow
OIOmer Inan
Omer Inan
Objective: To present a robust methodology for evaluating ankle health during ambulation using a wearable device. Methods: We developed a novel data capture system that leverages changes within the ankle during ambulation for real-time tracking of bioimpedance. The novel analysis compares the range of reactance at 5 kHz to the range of reactance at 100 kHz; which removes the technique's previous reliance on a known baseline. To aid in interpretation of the measurements, we developed a quantitative simulation model based on a literature review of the effects on joint bioimpedance of variations in edematous fluid volume, muscle fiber tears, and blood flow changes. Results: The results of the simulation predicted a significant difference in the ratio of the range of the reactance from 5 kHz to 100 kHz between the healthy and injured ankles. These results were validated in 15 subjects - with 11 healthy ankles and 7 injured ankles measured. The injured subjects had lateral ankle sprains 2-4 weeks prior to the measurement. The analysis technique differentiated between the healthy and the injured population (p<<0.01), and a correlation (R = 0.8) with a static protocol previously validated for its sensitivity to edema. Conclusion: The technology presented can detect variations in ankle edema and structural integrity of ankles, and thus could provide valuable feedback to clinicians and patients during the rehabilitation of an ankle injury. Significance: This technology could lead to better-informed decision making regarding a patient's readiness to return to activity and / or tailoring rehabilitation activities to an individual's changing needs.

23 May 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KRKristine L. Richardson
Kristine L. Richardson
CTCaitlin N. Teague
Caitlin N. Teague
SMSamer Mabrouk
Samer Mabrouk
BNBrandi N. Nevius
Brandi N. Nevius
GOGoktug Ozmen
Goktug Ozmen
OIOmer Inan
Omer Inan
Objective: Rheumatoid arthritis (RA) is a chronic inflammatory syndrome that features painful and destructive joint disease. Aggressive disease-modifying treatment can result in reduced symptoms and protection from irreversible joint damage; however, assessment of treatment efficacy is currently based largely on subjective measures of patient and physician impressions. In this work, we address this compelling need to provide an accurate and quantitative capability for monitoring joint health in patients with RA. Methods: Joint acoustic emissions (JAEs), electrical bioimpedance (EBI), and kinematics were measured noninvasively from 11 patients with RA over the course of three weeks using a custom multimodal sensing brace, resulting in 49 visits with JAE recordings and 43 with EBI recordings. Features derived from all sensing modalities were fed into a linear discriminant analysis (LDA) model to predict disease activity according to the validated disease activity index (the DAS28-ESR). Erythrocyte sedimentation rate (ESR) was predicted using ridge regression and classified into a high or low class using LDA. Results: DAS28-ESR level was predicted with an area under the receiver operating characteristic curve (AUC) of 0.82. With JAEs alone, we were able to track intrasubject differences in the disease activity score as well as classify ESR level with an AUC of 0.93. The majority of patients reported both an interest and ability to use the brace at home for longitudinal monitoring. Conclusion: This work demonstrates the ability to detect RA disease activity using noninvasive sensing. Significance: This system has the potential to improve RA disease activity monitoring by giving treating clinicians objective data that can be acquired independent of a face-to-face clinic visit.