Marco Farronato

Dr. Marco Farronato

Faculty of Medicine, Orthodontics department, Università degli Studi di Milano, 20122 Milan, Italy
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 April 2021 in Materials
Verified
Journal Article
Open access
PDF file
Gianluca TartagliaGianluca Tartaglia
Gianluca Tartaglia
AMAndrea Mapelli
Andrea Mapelli
Cinzia MasperoCinzia Maspero
Cinzia Maspero
TSTommaso Santaniello
Tommaso Santaniello
MSMarco Serafin
Marco Serafin
Alberto CaprioglioAlberto Caprioglio
Alberto Caprioglio
The recent introduction of three-dimensional (3D) printing is revolutionizing dentistry and is even being applied to orthodontic treatment of malocclusion. Clear, personalized, removable aligners are a suitable alternative to conventional orthodontic appliances, offering a more comfortable and efficient solution for patients. Including improved oral hygiene and aesthetics during treatment. Contemporarily, clear aligners are produced by a thermoforming process using various types of thermoplastic materials. The thermoforming procedure alters the properties of the material, and the intraoral environment further modifies the properties of a clear aligner, affecting overall performance of the material. Direct 3D printing offers the creation of highly precise clear aligners with soft edges, digitally designed and identically reproduced for an entire set of treatment aligners; offering a better fit, higher efficacy, and reproducibility. Despite the known benefits of 3D printing and the popularity of its dental applications, very limited technical and clinical data are available in the literature about directly printed clear aligners. The present article discusses the advantages of 3D printed aligners in comparison to thermoformed ones, describes the current state of the art, including a discussion of the possible road blocks that exist such as a current lack of approved and marketed materials and limited existence of aligner specific software. The present review suggests the suitability of 3D direct printed aligners is superior to that of thermoformed manufactured aligners because of the prior’s increased accuracy, load resistance, and lower deformation. It is an overall more stable way to produce an aligner where submillimeter movements can make a difference in treatment outcome. Direct 3D printing represents a complex method to control the thickness of the aligner and therefore has a better ability to control the force vectors that are used to produce tooth movement. There is currently no other approved material on the market that can do this. The conclusion of this article is that we encourage further in vitro and in vivo studies to test these new technologies and materials.

11 January 2022 in Materials
Verified
Journal Article
Open access
PDF file
Riccardo NuceraRiccardo Nucera
Riccardo Nucera
CDCarolina Dolci
Carolina Dolci
ABAngela Mirea Bellocchio
Angela Mirea Bellocchio
SCStefania Costa
Stefania Costa
SBSerena Barbera
Serena Barbera
Marco PortelliMarco Portelli
Marco Portelli
This systematic review aims to highlight the differences between different clear aligner therapies that differ in the presence of attachments or in attachment configuration. Eight electronic databases were searched up to March 2020. Two authors independently proceeded to study selection, data extraction, and risk of bias assessment. The analysis of the results was carried out examining six groups of movements (mesio-distal tipping/bodily movement; anterior bucco-lingual tipping/root torque; posterior bucco-lingual tipping/expansion; intrusion; extrusion; rotation). Five clinical trials were selected and all of them showed a medium risk of bias. Literature showed that attachments mostly increase the effectiveness of orthodontic treatment with clear aligners, improving anterior root torque, rotation, and mesio-distal (M-D) movement; they are also important to increase posterior anchorage. However, some articles showed contradictory or not statistically significant results. Attachments also seem to improve intrusion, but the evidence about this movement, as well as extrusion, is lacking. No studies evaluated posterior bucco-lingual tipping/expansion. Further clinical trials are strongly suggested to clarify the influence of attachments and their number, size, shape, and position on each orthodontic movement.

Verified
Journal Article
Open access
PDF file
Cinzia MasperoCinzia Maspero
Cinzia Maspero
Andrea AbateAndrea Abate
Andrea Abate
davide cavagnettodavide cavagnetto
davide cavagnetto
MMMohamed El Morsi
Mohamed El Morsi
AFAndrea Fama
Andrea Fama
Marco FarronatoMarco Farronato
Marco Farronato
Background: COVID-2019 spread rapidly throughout the world from China. This infection is highly contagiousness, has a high morbidity, and is capable of evolving into a potentially lethal form of interstitial pneumonia. Numerous countries shut-down various activities that were considered “not essential.” Dental treatment was in this category and, at the time of writing, only non-deferrable emergencies are still allowed in many countries. Therefore, follow-up visits of ongoing active therapies (e.g., orthodontic treatment) must be handled taking special precautions. This literature review aims at reducing in-office appointments by providing an overview of the technologies available and their reliability in the long-distance monitoring of patients, i.e., teledentistry. Methods: A literature review was made according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses Protocols (PRISMA-P) guidelines. Randomized clinical trials, cross sectional, observational, and case-control studies were evaluated with the Mixed Methods Appraisal Tool for quality assessment and study limitations. Results: A primary search found 80 articles, 69/80 were excluded as non-relevant on the basis of: the abstract, title, study design, bias, and/or lack of relevance. Twelve articles were included in the qualitative analysis. Conclusions: Teleorthodontics can manage most emergencies, reassuring and following patients remotely. The aim set by dental teleassistance was met as it reduced patients’ office visits whilst maintaining regular monitoring, without compromising the results. Although our preliminary findings should be further investigated to objectively evaluate the efficacy, cost-effectiveness, and long-term results, we are confident that teleassistance in orthodontics will have a role to play in the near future.

8 July 2019 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
Marco FarronatoMarco Farronato
Marco Farronato
Cinzia MasperoCinzia Maspero
Cinzia Maspero
Lanteri ValentinaLanteri Valentina
Lanteri Valentina
AFAndrea Fama
Andrea Fama
FFFrancesco Ferrati
Francesco Ferrati
Davide FarronatoDavide Farronato
Davide Farronato
The aim of the present systematic review was to screen the literature and to describe current applications of augmented reality. The protocol design was structured according to PRISMA-P guidelines and registered in PROSPERO. A review of the following databases was carried out: Medline, Ovid, Embase, Cochrane Library, Google Scholar and the Gray literature. Data was extracted, summarized and collected for qualitative analysis and evaluated for individual risk of bias (R.O.B.) assessment, by two independent examiners. Collected data included: year of publishing, journal with reviewing system and impact factor, study design, sample size, target of the study, hardware(s) and software(s) used or custom developed, primary outcomes, field of interest and quantification of the displacement error and timing measurements, when available. Qualitative evidence synthesis refers to SPIDER. From a primary research of 17,652 articles, 33 were considered in the review for qualitative synthesis. 16 among selected articles were eligible for quantitative synthesis of heterogenous data, 12 out of 13 judged the precision at least as acceptable, while 3 out of 6 described an increase in operation timing of about 1 h. 60% (n = 20) of selected studies refers to a camera-display augmented reality system while 21% (n = 7) refers to a head-mounted system. The software proposed in the articles were self-developed by 7 authors while the majority proposed commercially available ones. The applications proposed for augmented reality are: Oral and maxillo-facial surgery (OMS) in 21 studies, restorative dentistry in 5 studies, educational purposes in 4 studies and orthodontics in 1 study. The majority of the studies were carried on phantoms (51%) and those on patients were 11 (33%). On the base of literature the current development is still insufficient for full validation process, however independent sources of customized software for augmented reality seems promising to help routinely procedures, complicate or specific interventions, education and learning. Oral and maxillofacial area is predominant, the results in precision are promising, while timing is still very controversial since some authors describe longer preparation time when using augmented reality up to 60 min while others describe a reduced operating time of 50/100%. The following systematic review was registered in PROSPERO with RN: CRD42019120058.

1 May 2022 in The Angle Orthodontist
Verified
Journal Article
Open access
GDGiorgio D‘eTtorre
Giorgio D‘eTtorre
Marco FarronatoMarco Farronato
Marco Farronato
ECEttore Candida
Ettore Candida
VQVincenzo Quinzi
Vincenzo Quinzi
CGCristina Grippaudo
Cristina Grippaudo
Objectives: To compare three-dimensional facial scans obtained by stereophotogrammetry with two different applications for smartphone supporting the TrueDepth system, a structured light technology. Materials and Methods: Facial scans of 40 different subjects were acquired with three different systems. The 3dMDtrio Stereophotogrammetry System (3dMD, Atlanta, Ga) was compared with a smartphone (iPhone Xs; Apple, Cupertino, Calif) equipped with the Bellus3D Face Application (version 1.6.11; Bellus3D Inc, Campbell, Calif) or Capture (version 1.2.5; Standard Cyborg Inc, San Francisco, Calif). Times of image acquisition and elaboration were recorded. The surface-to-surface deviation and the distance between 18 landmarks from 3dMD reference images to those acquired with Bellus3D or Capture were measured. Results: Capturing and processing times with the smartphone applications were considerably longer than with the 3dMD system. The surface-to-surface deviation analysis between the Bellus3D and 3dMD showed an overlap percentage of 80.01% ± 5.92% and 56.62% ± 7.65% within the ranges of 1 mm and 0.5 mm discrepancy, respectively. Images from Capture showed an overlap percentage of 81.40% ± 9.59% and 56.45% ± 11.62% within the ranges of 1 mm and 0.5 mm, respectively. Conclusions: The face image acquisition with the 3dMD device is fast and accurate, but bulky and expensive. The new smartphone applications combined with the TrueDepth sensors show promising results. They need more accuracy from the operator and more compliance from the patient because of the increased acquisition time. Their greatest advantages are related to cost and portability.

1 September 2022 in Polymers
Verified
Journal Article
Open access
PDF file
EBElisa Brambilla
Elisa Brambilla
SLSilvia Alice Locarno
Silvia Alice Locarno
Salvatore GalloSalvatore Gallo
Salvatore Gallo
FOFrancesco Orsini
Francesco Orsini
CPCarolina Pini
Carolina Pini
Gianluca TartagliaGianluca Tartaglia
Gianluca Tartaglia
Thermogelling amphiphilic block copolymers have been widely investigated in the development of pharmaceutical drug carriers. In particular, thermosensitive gels based on poloxamer 407 (P407) have great potential for periodontal disease treatment, thanks to their ability to be liquid at room temperature and become viscous gels at body temperature. However, some problems, related to short in situ residence time, reduce their feasible clinical use. Thus, in order to improve the effective applicability of these materials, we studied how P407 thermogels are affected by the pH and by the inclusion of different hydrophilic polymers, used as excipients for increasing the gel stiffness. For this scope, a complete chemical-physical characterization of the synthesized gels is provided, in terms of determination of sol-gel transition temperature, viscosity and erosion degree. The data are correlated according to a statistical multivariate approach based on Principal Component Analysis and their mucoadhesion properties are also tested by Tapping mode-Atomic Force Microscopy (TM-AFM) imaging. Finally, we studied how the different P407 formulations are able to influence the release pathway of two antibacterial drugs (i.e., chlorhexidine digluconate and doxycycline hyclate) largely used in oral diseases.