Min Sook Kim

Dr. Min Sook Kim

Department Architectural Engineering, Kyung Hee University, Seoul 02447, Korea.
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2022 in Materials
Verified
Journal Article
Open access
PDF file
MKMin Sook Kim
Min Sook Kim
YLYoung Hak Lee
Young Hak Lee
In the existing reinforced concrete columns where they are insufficient seismic details, critical failure mode such as shear failure can be observed under seismic loads. One strategy for the retrofitting of existing concrete columns is to use concrete jacketing. Concrete jacketing consists of a new concrete layer with longitudinal and transverse reinforcements, and can improve seismic resistance capacity. In this paper, a detail of concrete jacket that can be expected for easy construction and improved adhesion performance of longitudinal and transverse reinforcement was proposed. Additionally, a combined cyclic loading test was conducted to consider the seismic load with multiaxial characteristics. The concrete jacket details utilize three components: Steel Grid Reinforcement (SGR), Steel Wire Mesh (SWM), and Steel Fiber Non-Shrinkage Mortar (SFNM). One RC column with non-seismic details and two jacketed RC columns were fabricated to demonstrate the construction efficiencies and structural capacities of the jacketed columns. Two details of jacketed section were considered as variables. It was observed that the specimens retrofitted with concrete jacket resisted torsional load more than the un-retrofitted specimen in terms of crack and failure mode. The experimental results showed that the maximum load of retrofitted specimens was increased by more than 8 times compared to the un-retrofitted specimen, regardless of the jacket details. Newly designed concrete jacket effectively increased the strength. Compared with the un-retrofitted column, the columns retrofitted with the proposed details achieved significant increase in initial stiffness and energy dissipation.

6 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MKMin Sook Kim
Min Sook Kim
YLYoung Hak Lee
Young Hak Lee
Many structural retrofitting methods tend to only focus on how to improve the strength and ductility of structural members. It is necessary for developing retrofitting strategy to consider not only upgrading the capacity but also achieving rapid and economical construction. In this paper, a new retrofitting details and technique is proposed to improve structural capacity and constructability for retrofitting reinforced concrete beams. The components of retrofitting are prefabricated, and the components are quickly assembled using bolts and chemical anchors on site. The details of modularized steel plates for retrofitting have been chosen based on the finite element analysis. To evaluate the structural performance of concrete beams retrofitted with the proposed details, five concrete beams with and without retrofitting were tested. The proposed retrofitting method significantly increased both the maximum load capacity and ductility of reinforced concrete beams. The test results showed that the flexural performance of the existing reinforced concrete beams increased by 3 times, the ductility by 2.5 times, and the energy dissipation capacity by 7 times.

1 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
KRkyong min ro
kyong min ro
MKMin Sook Kim
Min Sook Kim
YLYoung Hak Lee
Young Hak Lee
The concrete jacketing method for retrofitting old reinforced concrete (RC) columns should secure confinement and seismic performance under torsion as well as unidirectional later loads. In a previous study, a hybrid concrete jacketing method was proposed using steel wire mesh (SWM), steel grid reinforcement (SGR), which can replace reinforcement of existing concrete jacketing method, and using steel fiber non-shrinkage mortar (SFNM). These details can simplify the retrofitting process of the existing concrete jacketing method, and seismic performance was evaluated by conducting a cyclic loading test under unidirectional loading. In this paper, the torsional behavior of RC columns retrofitted with the hybrid concrete jacketing method was investigated. Four specimens were fabricated and conducted cyclic loading tests under two types of loading schemes, unidirectional and bidirectional loading, to examine the effect of the loading path. The strength and energy dissipation capacity of retrofitted columns with hybrid concrete jackets increased approximately eight times compared to the old RC columns under torsional loading. Therefore, the hybrid concrete jacketing method can improve torsional resistance.

27 April 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KRkyong min ro
kyong min ro
MKMin Sook Kim
Min Sook Kim
YLYoung Hak Lee
Young Hak Lee
This paper evaluated the validity of a design method for anchorage zones in post-tensioned concrete members using Grade 2400 strands from American Concrete Institute (ACI) Building Code, ACI 318-19 and Association of State Highway and Transportation Officials (AASHTO) codes. For this purpose, the behaviors of anchorage zones in ten specimens were investigated and compared with ACI 318-19 and AASHTO codes, considering the jacking force and ultimate flexural load. The anchor shape, number of strands, and reinforcement details of the anchorage zone were considered as variables. The test results showed that ACI 318-19 and AASHTO codes could not predict where the maximum bursting force would occur. In addition, they calculated bursting force by summation of the pre-stressing forces from the individual strands, whereas the experimental results were not linearly proportional to the number of strands. The ACI 318-19 and AASHTO standards were inadequate to calculate bearing force of post-tensioned members using high-strength strands. Furthermore, additional stress in the anchorage zone occurred as the flexural load increased, which may have been caused by a failure in the anchorage zone. The experimental results indicated that the method used to predict stress and design of anchorage zone in current codes should be improved to consider stress distribution and additional stress in post-tensioned concrete members using high-strength strands.

12 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KRkyong min ro
kyong min ro
MKMin Sook Kim
Min Sook Kim
YLYoung Hak Lee
Young Hak Lee
Buildings constructed with non-seismic details are at risk of damage and collapse when an earthquake occurs due to a lack of strength, stiffness, and ductility. For reinforced concrete (RC) moment-resisting frames, seismic retrofitting methods that can enhance strength or ductility should be applied. However, such strategies have many disadvantages related to constructability, serviceability, securing integrity, and cost. In this paper, a welded concrete-filled steel tube (WCFST) system was examined in order to resolve the problems of the existing seismic retrofitting methods for RC moment-resisting frames. To evaluate the seismic performance of the proposed system, two specimens, one with non-seismic details and another reinforced with a WCFST seismic system, were manufactured for the cyclic loading tests. As a result of the experiments, the specimen retrofitted with the WCFST system showed maximum load, effective stiffness, and energy dissipation capacity values approximately 3, 2, and 2.5 times greater, respectively, than those obtained from the existing reinforced concrete frame specimen. The experimental results indicate that the proposed WCFST system is expected to be effective at improving the seismic performance by enhancing both the strength of the existing reinforced concrete frame structures and the dissipation of the seismic energy.

18 March 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MKMin Sook Kim
Min Sook Kim
YLYoung Hak Lee
Young Hak Lee
In this study, the structural behavior of reinforced concrete flat plates shear reinforced with vertical grids made of a glass fiber reinforced polymer (GFRP) was experimentally evaluated. To examine the shear strength, experiments were performed on nine concrete slabs with different amounts and spacings of shear reinforcement. The test results indicated that the shear strength increased as the amount of shear reinforcement increased and as the spacing of the shear reinforcement decreased. The GFRP shear reinforcement changed the cracks and failure mode of the specimens from a brittle punching to flexure one. In addition, the experimental results are compared with a shear strength equation provided by different concrete design codes. This comparison demonstrates that all of the equations underestimate the shear strength of reinforced concrete flat plates shear reinforced with GFRP vertical grids. The shear strength of the equation by BS 8110 is able to calculate the punching shear strength reasonably for a concrete flat plate shear reinforced with GFRP vertical grids.