Lidan Zhou

Dr. Lidan Zhou

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2025 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
ZWZiqiang Wang
Ziqiang Wang
LZLidan Zhou
Lidan Zhou
Linyun XiongLinyun Xiong
Linyun Xiong
QZQuan Zhou
Quan Zhou
WHWentao Huang
Wentao Huang
YCYandong Chen
Yandong Chen
Green hydrogen produced from renewable energy generation (RES) is facilitating the energy transition. Due to the complicated operational constraints of green-hydrogen hybrid energy storage system (GH-HESS), the existing two-layer power-based control architecture is prevalent, but it heavily relies on the communication infrastructure and the prediction accuracy of RES’s power. Therefore, this paper proposes a novel voltage-source hierarchical control framework for the grid-connected GH-HESS to solve the above problems. Considering the electricity price, the hot-standby current and safety of the hydrogen production of the electrolyzer, the current allocation between hydrogen energy storage and power grid is achieved for the continuous stable operation of GH-HESS even in the situation with potential communication failure. When the current rate limiter is adopted for the fuel starvation phenomenon of fuel cell, the current feed-forward loop and current-based secondary control are designed to solve the trade-off problem between the current overshoot and convergence speed of the tradition voltage-source control, where the large current overshoot will cause irreversible damage to hydrogen energy storage. Battery energy storage rapidly responses the power fluctuation from RES, while the steady-state power vacancy is undertaken by hydrogen energy storage. Finally, a 800V DC microgrid based on NI-PXI real-time platform is built to validate its advantages.

10 May 2024 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
ZWZiqiang Wang
Ziqiang Wang
LZLidan Zhou
Lidan Zhou
Linyun XiongLinyun Xiong
Linyun Xiong
Haosen YangHaosen Yang
Haosen Yang
Jie WangJie Wang
Jie Wang
Sunhua HuangSunhua Huang
Sunhua Huang
Information disclosure is a potential challenge in the practical implement of distributed algorithm and wireless communications on islanded AC microgrid (MG) for better flexibility and low cost. It can be solved by the initial-value-around and real-time-values privacy preservations against internal curious distributed generations (DGs) and external cyber attackers respectively. However, three problems should be solved before the existing information privacy-preserving mechanisms implemented on control level: (i) Encryption algorithm for real-time-values privacy will exacerbate the delay problem; (ii) When the delay problem is solved by the existing distributed model predictive controls, the decaying disturbance for initial-value-around privacy will impact the stability of islanded AC MG; (iii) The compromise problem between the privacy-preserving performance and transient performance of distributed model-predictive control (DMPC) is unacceptable. For the above problems, this paper proposes a parameter-adaptive DMPC (PA-DMPC), where two decaying functions are designed to adjust parameters in terminal constraints and optimal cost function for the third problem. The optimal control results are obtained by solving time-varying quadratic programming (QP) problem. The real-time simulation platform based on NI-PXI (National Instruments-PCI eXtensions for Instrumentation) and Wireless Local Area Network (WLAN) is built to validate its effectiveness and advantages.

10 January 2020 in Electronics
Verified
Journal Article
Open access
PDF file
RBRABAH BOUDINA
RABAH BOUDINA
Jie WangJie Wang
Jie Wang
Mohamed BenbouzidMohamed Benbouzid
Mohamed Benbouzid
GYGang Yao
Gang Yao
LZLidan Zhou
Lidan Zhou
The future adoption of electric vehicles (EV) as the main means of commuting will put an additional stress on the distribution grid; the level where EVs are mainly expected to be charged. Estimation of the EV charging influence on the distribution grid is a critical task for distribution system operators (DSO) in order to plan for grid reinforcement and to avoid service failure. Due to the unpredictable nature of daily human activities, stochastic modeling for daily EVs’ owner behavior and residential power consumption is needed. In our study a new estimation model for the EV power demand during the charging process is developed to accurately estimate the charging demand, which is combined with daily household power consumption loads based on real life measurements to estimate the total demand in the system. This demand can be applied to the standard IEEE 69 distribution system and can quantify the influence of different penetration levels under an uncontrolled (dumb) charging case, also under a proposed controlled charging algorithm for both summer and winter seasons.

16 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
ALAnil Lamichhane
Anil Lamichhane
LZLidan Zhou
Lidan Zhou
GYGang Yao
Gang Yao
MLMuhammad Luqman
Muhammad Luqman
In the modern shipboard power system, there is a growing concern about reduced fuel economy, efficiency improvement, and minimized emission in recent years. Besides, considering the islanded nature of the shipboard power system, ensuring the system reliability at both generation and load side is crucial. In this context, a hybrid medium voltage DC (MVDC) distribution system concept with diesel engine, PV system, and battery energy storage system (BESS) as the generators for the shipboard power system is proposed. Variable speed operation of a diesel engine is considered for the benefit of minimal specific fuel oil consumption (SFOC). Regarding the fault-tolerant characteristics of six-phase permanent magnet synchronous machine (PMSM), it is used for both generating and motoring application, thus maintaining system reliability at any time. A hierarchical control system is designed and implemented to ensure proper load power-sharing among the generators and to regulate the dc-link voltage of the proposed MVDC distribution system. To bolster the intent of minimal SFOC zone operation of diesel engines and coordination between the generators and load, a deterministic rule-based power management system is proposed and implemented. The simulation is carried out for potential operational modes of a cruise ship in the MATLAB/Simulink environment. Simulation results show that the proposed topological and control structure has satisfactory performance in terms of power delivery, stable dc-link dynamics, and overall system stability.

1 November 2019 in Energies
Verified
Journal Article
Open access
PDF file
MLMuhammad Luqman
Muhammad Luqman
GYGang Yao
Gang Yao
LZLidan Zhou
Lidan Zhou
TZTao Zhang
Tao Zhang
ALAnil Lamichhane
Anil Lamichhane
Modern multi-MW wind generators have used multi-level converter structures as well as parallel configuration of a back to back three-level neutral point clamped (3L-NPC) converters to reduce the voltage and current stress on the semiconductor devices. These configurations of converters for offshore wind energy conversion applications results in high cost, low power density, and complex control circuitry. Moreover, a large number of power devices being used by former topologies results in an expensive and inefficient system. In this paper, a novel bi-directional three-phase hybrid converter that is based on a parallel combination of 3L-NPC and ‘n’ number of Vienna rectifiers have been proposed for multi-MW offshore wind generator applications. In this novel configuration, total power equally distributes by sharing of total reference current in each parallel-connected generator side power converter, which ensures the lower current stress on the semiconductor devices. Newly proposed topology has less number of power devices compared to the conventional configuration of parallel 3L-NPC converters, which results in cost-effective, compact in size, simple control circuitry, and good performance of the system. Three-phase electric grid is considered as a generator source for implementation of a proposed converter. The control scheme for a directly connected three-phase source with a novel configuration of a hybrid converter has been applied to ratify the equal power distribution in each parallel-connected module with good power factor and low current distortion. A parallel combination of a 3L-NPC and 3L-Vienna rectifier with a three-phase electric grid source has been simulated while using MATLAB and then implemented it on hardware. The simulation and experimental results ratify the performance and effectiveness of the proposed system.

28 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
CHChen Huang
Chen Huang
LZLidan Zhou
Lidan Zhou
ZCZujia Cao
Zujia Cao
GYGang Yao
Gang Yao
Multi-phase motors and generators are regarded with great fault tolerance capability, especially on open-circuit faults. Various mathematics analytical methods are applied for their fault control. In this paper, a fault-tolerant control strategy with asymmetric phase current for the open-circuit faults with arbitrary phases in the six-phase PMSM (six-phase permanent magnetic synchronous motor, 6P-PMSM) system, is proposed for better electrical and dynamical performance of the machine. An innovative mathematical model for PMSM under one to four-phase-open circuit faults are established considering the asymmetry of the machine. Combining with time-varying relations in machines’ working conditions, targeted decoupling transformation matrixes of every kind of open-circuit faults are settled by voltage equations under different faults. Modified control strategy with a connection between the neutral point and the inverter’s DC side is presented, which aims at increasing the system redundancy and reducing the amplitude of phase currents. Besides, improved control loops with two layers are put forward as well, with which the PMSM system acquires fewer harmonics in phase current and smoother electromagnetic torque. Simulation and experimental results of open-circuit faults are provided for verification of the theoretical analysis.