This paper proposes a model predictive direct power control scheme for nonredundant fault tolerant grid-connected bidirectional voltage source converter (BVSC) with balanced dc-link split capacitor voltage and high reliability. Based on the operation analysis of fault-tolerant BVSC with phase leg faults, a power predictive model of three-phase four-switch fault-tolerant topology in αβ coordinates is established, and the space voltage vectors with unbalanced dc-link split capacitor voltage are analyzed. According to the power predictive model and cost function, the optimal space voltage vector is selected to achieve a flexible, smooth transition between inverter and rectifier mode with direct power control. Pulse width modulation and phase locked loop are not required in the proposed method. The constraint of dc-link voltage constraint is designed for the cost function to achieve a central point of dc-link voltage offset suppression, which can reduce the risk of electrolytic capacitor failure for over-voltage operation. With the proposed control method, the converter can work continuously in both inverter mode and rectifier mode, even if phase leg faults occur. The simulation and experimental results show good steady-state and dynamic performance of the proposed control scheme to enhance the reliability of bidirectional power conversion.
The future adoption of electric vehicles (EV) as the main means of commuting will put an additional stress on the distribution grid; the level where EVs are mainly expected to be charged. Estimation of the EV charging influence on the distribution grid is a critical task for distribution system operators (DSO) in order to plan for grid reinforcement and to avoid service failure. Due to the unpredictable nature of daily human activities, stochastic modeling for daily EVs’ owner behavior and residential power consumption is needed. In our study a new estimation model for the EV power demand during the charging process is developed to accurately estimate the charging demand, which is combined with daily household power consumption loads based on real life measurements to estimate the total demand in the system. This demand can be applied to the standard IEEE 69 distribution system and can quantify the influence of different penetration levels under an uncontrolled (dumb) charging case, also under a proposed controlled charging algorithm for both summer and winter seasons.
In the modern shipboard power system, there is a growing concern about reduced fuel economy, efficiency improvement, and minimized emission in recent years. Besides, considering the islanded nature of the shipboard power system, ensuring the system reliability at both generation and load side is crucial. In this context, a hybrid medium voltage DC (MVDC) distribution system concept with diesel engine, PV system, and battery energy storage system (BESS) as the generators for the shipboard power system is proposed. Variable speed operation of a diesel engine is considered for the benefit of minimal specific fuel oil consumption (SFOC). Regarding the fault-tolerant characteristics of six-phase permanent magnet synchronous machine (PMSM), it is used for both generating and motoring application, thus maintaining system reliability at any time. A hierarchical control system is designed and implemented to ensure proper load power-sharing among the generators and to regulate the dc-link voltage of the proposed MVDC distribution system. To bolster the intent of minimal SFOC zone operation of diesel engines and coordination between the generators and load, a deterministic rule-based power management system is proposed and implemented. The simulation is carried out for potential operational modes of a cruise ship in the MATLAB/Simulink environment. Simulation results show that the proposed topological and control structure has satisfactory performance in terms of power delivery, stable dc-link dynamics, and overall system stability.
Modern multi-MW wind generators have used multi-level converter structures as well as parallel configuration of a back to back three-level neutral point clamped (3L-NPC) converters to reduce the voltage and current stress on the semiconductor devices. These configurations of converters for offshore wind energy conversion applications results in high cost, low power density, and complex control circuitry. Moreover, a large number of power devices being used by former topologies results in an expensive and inefficient system. In this paper, a novel bi-directional three-phase hybrid converter that is based on a parallel combination of 3L-NPC and ‘n’ number of Vienna rectifiers have been proposed for multi-MW offshore wind generator applications. In this novel configuration, total power equally distributes by sharing of total reference current in each parallel-connected generator side power converter, which ensures the lower current stress on the semiconductor devices. Newly proposed topology has less number of power devices compared to the conventional configuration of parallel 3L-NPC converters, which results in cost-effective, compact in size, simple control circuitry, and good performance of the system. Three-phase electric grid is considered as a generator source for implementation of a proposed converter. The control scheme for a directly connected three-phase source with a novel configuration of a hybrid converter has been applied to ratify the equal power distribution in each parallel-connected module with good power factor and low current distortion. A parallel combination of a 3L-NPC and 3L-Vienna rectifier with a three-phase electric grid source has been simulated while using MATLAB and then implemented it on hardware. The simulation and experimental results ratify the performance and effectiveness of the proposed system.
Multi-phase motors and generators are regarded with great fault tolerance capability, especially on open-circuit faults. Various mathematics analytical methods are applied for their fault control. In this paper, a fault-tolerant control strategy with asymmetric phase current for the open-circuit faults with arbitrary phases in the six-phase PMSM (six-phase permanent magnetic synchronous motor, 6P-PMSM) system, is proposed for better electrical and dynamical performance of the machine. An innovative mathematical model for PMSM under one to four-phase-open circuit faults are established considering the asymmetry of the machine. Combining with time-varying relations in machines’ working conditions, targeted decoupling transformation matrixes of every kind of open-circuit faults are settled by voltage equations under different faults. Modified control strategy with a connection between the neutral point and the inverter’s DC side is presented, which aims at increasing the system redundancy and reducing the amplitude of phase currents. Besides, improved control loops with two layers are put forward as well, with which the PMSM system acquires fewer harmonics in phase current and smoother electromagnetic torque. Simulation and experimental results of open-circuit faults are provided for verification of the theoretical analysis.
The unipolar‐input bipolar‐output DC–DC converters with megawatt rating are the key equipment in the multi‐terminal HVDC and DC grids, especially in the DC wind farm. This paper presents a novel direct‐coupled transformerless DC–DC converter to interconnect unipolar DC system with bipolar DC transmission line based on cascaded sub‐modules. The sub‐modules can be achieved by active clamping (clamped diode), half bridge and full bridge. The proportional‐integral control strategy is employed to balance the capacitors' voltages in several sub‐modules and the energy between the upper and lower arms. Compared with other bipolar output DC–DC converters, the new direct‐coupled DC–DC converter offers several merits: (1) The volume and the cost can be reduced due to the absence of the transformer and the large‐scale sub‐module capacitance; (2) There is no extra AC–DC conversion process, so it can achieve higher efficiency; (3) The IGBTs only turn on or off once in a period, which results in lower power loss; (4) High step‐up ratio, redundancy, and fault tolerance can be achieved by changing the number of sub‐modules. Finally, the simulation of the proposed DC–DC converter based on MATLAB/Simulink platform is given to verify the feasibility of the topology and the accuracy of the theoretical analysis.