Sasha Cai Lesher-Perez

Mr. Sasha Cai Lesher-Perez

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2017 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
SLSasha Cai Lesher-Perez
Sasha Cai Lesher-Perez
GKGe-Ah Kim
Ge-Ah Kim
CKChuan-Hsien Kuo
Chuan-Hsien Kuo
BLBrendan M. Leung
Brendan M. Leung
SMSanda Mong
Sanda Mong
STShuichi Takayama
Shuichi Takayama
Oxygen measurements in different microtissue culture environments were accomplished with the use of phase fluorimetry on dispersible oxygen microsensors.

5 May 2021 in Small
Verified
Journal Article
Open access
PDF file
PSPriyanka Sharan
Priyanka Sharan
ANAudrey Nsamela
Audrey Nsamela
SLSasha Cai Lesher-Perez
Sasha Cai Lesher-Perez
JSJuliane Simmchen
Juliane Simmchen
This paper provides an updated review of recent advances in microfluidics applied to artificial and biohybrid microswimmers. Sharing the common regime of low Reynolds number, the two fields have been brought together to take advantage of the fluid characteristics at the microscale, benefitting microswimmer research multifold. First, microfluidics offer simple and relatively low‐cost devices for high‐fidelity production of microswimmers made of organic and inorganic materials in a variety of shapes and sizes. Microscale confinement and the corresponding fluid properties have demonstrated differential microswimmer behaviors in microchannels or in the presence of various types of physical or chemical stimuli. Custom environments to study these behaviors have been designed in large part with the help of microfluidics. Evaluating microswimmers in increasingly complex lab environments such as microfluidic systems can ensure more effective implementation for in‐field applications. The benefits of microfluidics for the fabrication and evaluation of microswimmers are balanced by the potential use of microswimmers for sample manipulation and processing in microfluidic systems, a large obstacle in diagnostic and other testing platforms. In this review various ways in which these two complementary technology fields will enhance microswimmer development and implementation in various fields are introduced.

28 July 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
AMAlexander McMillan
Alexander McMillan
ETEmma K. Thomée
Emma K. Thomée
ADAlessandra Dellaquila
Alessandra Dellaquila
HNHussam Nassman
Hussam Nassman
TSTatiana Segura
Tatiana Segura
SLSasha Cai Lesher-Perez
Sasha Cai Lesher-Perez
Leveraging the advantageous material properties of recently developed soft thermoplastic elastomer materials, this work presents the facile and rapid fabrication of composite membrane-integrated microfluidic devices consisting of FlexdymTM polymer and commercially available porous polycarbonate membranes. The three-layer devices can be fabricated in under 2.5 h, consisting of a 2-min hot embossing cycle, conformal contact between device layers and a low-temperature baking step. The strength of the FlexdymTM-polycarbonate seal was characterized using a specialized microfluidic delamination device and an automated pressure controller configuration, offering a standardized and high-throughput method of microfluidic burst testing. Given a minimum bonding distance of 200 μm, the materials showed bonding that reliably withstood pressures of 500 mbar and above, which is sufficient for most microfluidic cell culture applications. Bonding was also stable when subjected to long term pressurization (10 h) and repeated use (10,000 pressure cycles). Cell culture trials confirmed good cell adhesion and sustained culture of human dermal fibroblasts on a polycarbonate membrane inside the device channels over the course of one week. In comparison to existing porous membrane-based microfluidic platforms of this configuration, most often made of polydimethylsiloxane (PDMS), these devices offer a streamlined fabrication methodology with materials having favourable properties for cell culture applications and the potential for implementation in barrier model organ-on-chips.

12 June 2025 in Acta Biomaterialia
Verified
Journal Article
Closed access
IZIrene W. Zhang
Irene W. Zhang
LCLucia S. Choi
Lucia S. Choi
NFNicole E. Friend
Nicole E. Friend
AMAtticus J. McCoy
Atticus J. McCoy
FMFiraol S. Midekssa
Firaol S. Midekssa
APAndrew J. Putnam
Andrew J. Putnam

27 November 2014 in Micromachines
Verified
Journal Article
Open access
PDF file
SLSasha Cai Lesher-Perez
Sasha Cai Lesher-Perez
PWPriyan Weerappuli
Priyan Weerappuli
Sung-Jin KimSung-Jin Kim
Sung-Jin Kim
CZChao Zhang
Chao Zhang
STShuichi Takayama
Shuichi Takayama
The ability to elicit distinct duty cycles from the same self-regulating microfluidic oscillator device would greatly enhance the versatility of this micro-machine as a tool, capable of recapitulating in vitro the diverse oscillatory processes that occur within natural systems. We report a novel approach to realize this using the coordinated modulation of input volumetric flow rate ratio and fluidic capacitance ratio. The demonstration uses a straightforward experimental system where fluid inflow to the oscillator is provided by two syringes (of symmetric or asymmetric cross-sectional area) mounted upon a single syringe pump applying pressure across both syringes at a constant linear velocity. This produces distinct volumetric outflow rates from each syringe that are proportional to the ratio between their cross-sectional areas. The difference in syringe cross-sectional area also leads to differences in fluidic capacitance; this underappreciated capacitive difference allows us to present a simplified expression to determine the microfluidic oscillators duty cycle as a function of cross-sectional area. Examination of multiple total volumetric inflows under asymmetric inflow rates yielded predictable and robust duty cycles ranging from 50% to 90%. A method for estimating the outflow duration for each inflow under applied flow rate ratios is provided to better facilitate the utilization of this system in experimental protocols requiring specific stimulation and rest intervals.

5 February 2021 in Nano Select
Verified
Journal Article
Open access
AMAlexander McMillan
Alexander McMillan
JMJuan Mora‐Macías
Juan Mora‐Macías
JTJoan Teyssandier
Joan Teyssandier
RTRaymond Thür
Raymond Thür
EREmmanuel Roy
Emmanuel Roy
SLSasha Cai Lesher-Perez
Sasha Cai Lesher-Perez