Sung-Jin Kim

Prof. Sung-Jin Kim

konkuk university
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2003 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
JKJong Soo Ko
Jong Soo Ko
Hyun C. YoonHyun C. Yoon
Hyun C. Yoon
Haesik YangHaesik Yang
Haesik Yang
HPHyeon-Bong Pyo
Hyeon-Bong Pyo
KCKwang Hyo Chung
Kwang Hyo Chung
YKYoun Tae Kim
Youn Tae Kim
This paper describes the design, fabrication, and test of a PDMS/PMMA-laminated microfluidic device for an immunosensing biochip. A poly(dimethyl siloxane) (PDMS) top substrate molded by polymer casting and a poly(methyl methacrylate) (PMMA) bottom substrate fabricated by hot embossing are bonded with pressure and hermetically sealed. Two inlet ports and an air vent are opened through the PDMS top substrate, while gold electrodes for electrochemical biosensing are patterned onto the PMMA bottom substrate. The analyte sample is loaded from the sample inlet port to the detection chamber by capillary force, without any external intervening forces. For this and to control the time duration of sample fluid in each compartment of the device, including the inlet port, diffusion barrier, reaction chamber, flow-delay neck, and detection chamber, the fluid conduit has been designed with various geometries of channel width, depth, and shape. Especially, the fluid path has been designed so that the sample flow naturally stops after filling the detection chamber to allow sufficient time for biochemical reaction and subsequent washing steps. As model immunosensing tests for the microfluidic device, functionalizations of ferritin and biotin to the sensing surfaces on gold electrodes and their biospecific interactions with antiferritin antiserum and streptavidin have been investigated. An electrochemical detection method for immunosensing by biocatalyzed precipitation has been developed and applied for signal registration. With the biochip, the whole immunosensing processes could be completed within 30 min.

29 March 2004 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
DLDae-Sik Lee
Dae-Sik Lee
SPSe Ho Park
Se Ho Park
Haesik YangHaesik Yang
Haesik Yang
KCKwang-Hyo Chung
Kwang-Hyo Chung
TYTae Hwan Yoon
Tae Hwan Yoon
YKYoun Tae Kim
Youn Tae Kim
The current paper describes the design, fabrication, and testing of a micromachined submicroliter-volume polymerase chain reaction (PCR) chip with a fast thermal response and very low power consumption. The chip consists of a bulk-micromachined Si component and hot-embossed poly(methyl methacrylate) (PMMA) component. The Si component contains an integral microheater and temperature sensor on a thermally well-isolated membrane, while the PMMA component contains a submicroliter-volume PCR chamber, valves, and channels. The micro hot membrane under the submicroliter-volume chamber is a silicon oxide/silicon nitride/silicon oxide (O/N/O) diaphragm with a thickness of 1.9 μm, resulting in a very low thermal mass. In experiments, the proposed chip only required 45 mW to heat the reaction chamber to 92 °C, the denaturation temperature of DNA, plus the heating and cooling rates are about 80 °C s−1 and 60 °C s−1, respectively. We validated, from the fluorescence results from DNA stained with SYBR Green I, that the proposed chip amplified the DNA from vector clone, containing tumor suppressor gene BRCA 1 (127 base pairs at 11th exon), after 30 thermal cycles of 3 s, 5 s, and 5 s at 92 °C, 55 °C, and 72 °C, respectively, in a 200 nL-volume chamber. As for specificity of DNA products, owing to difficulty in analyzing the very small volume PCR results from the micro chip, we vicariously employed the larger volume PCR products after cycling with the same sustaining temperatures as with the micro chip but with much slower ramping rates (3.3 °C s−1 when rising, 2.5 °C s−1 when cooling) within circa 20 minutes on a commercial PCR machine and confirmed the specificity to BRCA 1 (127 base pairs) with agarose gel electrophoresis. Accordingly, the fabricated micro chip demonstrated a very low power consumption and rapid thermal response, both of which are crucial to the development of a fully integrated and battery-powered instrument for a lab-on-a-chip DNA analysis.

6 May 2009 in Analytical Chemistry
Verified
Journal Article
Closed access
Sung-Jin KimSung-Jin Kim
Sung-Jin Kim
FWFang Wang
Fang Wang
MBMark A. Burns
Mark A. Burns
Katsuo KurabayashiKatsuo Kurabayashi
Katsuo Kurabayashi

1 April 2017 in Chemical Engineering Journal
Verified
Journal Article
Closed access
ZLZhenglin Li
Zhenglin Li
Sung-Jin KimSung-Jin Kim
Sung-Jin Kim

29 December 2011 in Analytical Chemistry
Verified
Journal Article
Closed access
Sung-Jin KimSung-Jin Kim
Sung-Jin Kim
RYRyuji Yokokawa
Ryuji Yokokawa
SLSasha Cai Lesher-Perez
Sasha Cai Lesher-Perez
STShuichi Takayama
Shuichi Takayama

3 February 2020 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
JKJoo Sung Kim
Joo Sung Kim
SLSeung Chul Lee
Seung Chul Lee
JHJinhyun Hwang
Jinhyun Hwang
ELEunho Lee
Eunho Lee
KCKilwon Cho
Kilwon Cho
WLWi Hyoung Lee
Wi Hyoung Lee