ZiHe Gao

Prof. Dr. ZiHe Gao

School of Civil Engineering, Zhengzhou University, Henan 450001, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2019 in Fire and Materials
Verified
Journal Article
Closed access
PDF file
LLLinjie Li
Linjie Li
ZiHe GaoZiHe Gao
ZiHe Gao
JJJie Ji
Jie Ji
JZJiping Zhu
Jiping Zhu
HWHaobo Wang
Haobo Wang
DZDechuang Zhou
Dechuang Zhou

14 July 2016 in Fire Technology
Verified
Journal Article
Closed access
PDF file
LLL. J. Li
L. J. Li
SLS. H. Lin
S. H. Lin
BYB. Yao
B. Yao
JJJie Ji
Jie Ji
ZiHe GaoZiHe Gao
ZiHe Gao
JSJ. H. Sun
J. H. Sun

12 May 2023 in Fire
Verified
Journal Article
Open access
PDF file
HQHengjie Qin
Hengjie Qin
JWJiangqi Wen
Jiangqi Wen
ZiHe GaoZiHe Gao
ZiHe Gao
LClingling chai
lingling chai
HYHao-wei YAO
Hao-wei YAO
Real-time acquisition and visualization of temperature anomalies in building spaces and 3D temperature field data during fires are of vital importance for fire danger warnings, early rescue operations, evacuation commands, and subsequent fire accident investigations. Taking into account the non-contact, global (planar and spatial), and high efficiency advantages of acoustic CT temperature measurement technology, this study involved the conducting of exploratory preliminary research in order to provide new ideas for the real-time global perception of information on building fires. The detailed research objective was as follows: obtain the temperature data at any time of a fire based on Fire Dynamics Simulator (FDS) and fit them to form the base temperature distribution diagram at that time. The large ill-conditioned matrix equation of acoustic flight under the scheme of multi-grid division was then constructed. The discrete temperature data of each grid in the building space was obtained by solving the matrix equation based on algebraic reconstruction algorithm (ART) and joint algebraic reconstruction algorithm (SART). The three-dimensional temperature field reconstruction of building space was realized by the interpolation of discrete temperature data. The reconstruction effect of each scheme was evaluated through the error analysis between the reconstruction data and the basic data. The results show that the real-time reconstruction of a 3D temperature field of a building thermal field can be realized based on acoustic CT temperature measurement technology, and the reconstruction algorithm and grid division scheme have a significant control effect on the reconstruction effect.

8 April 2024 in Indoor and Built Environment
Verified
Journal Article
Closed access
ZiHe GaoZiHe Gao
ZiHe Gao
JCJiajun Cai
Jiajun Cai
LJLin Jiang
Lin Jiang
RMRhoda Afriyie Mensah
Rhoda Afriyie Mensah
CFChuangang Fan
Chuangang Fan
In high-altitude tunnels, due to the ambient pressure and density of air being different from those under normal pressure, the convection and heat radiation in tunnels are also different when fires occur. As a result, the smoke exhaust capacity varies under different pressures. This work aimed to numerically explore the impact of ambient pressure on the smoke exhaust efficiency at high-altitude shallow tunnels with natural ventilation by shaft. The numerical results demonstrated that the smoke exhaust capacity is enhanced with increasing ambient pressure. This is because of the increase in the air entrainment coefficient and air density, and it causes plug-holing more easily to occur under higher ambient pressures. Once the plug-holing has taken place, the fresh air can be directly exhausted through the shaft, which results in a poor smoke exhaust capacity. By accounting for the factors of the smoke layer thickness, ambient pressure, the exhausted smoke temperature and heat release rate, the Richardson number was introduced as the criterion for determining whether plug-holing occurs. As ambient pressure was increased, the critical Richardson number for plug-holing was observed to decrease, a finding supported by existing research.

1 March 2024 in Fire
Verified
Journal Article
Open access
PDF file
YSYouzhi Shi
Youzhi Shi
SQShixiong Qian
Shixiong Qian
PZPengju Zhao
Pengju Zhao
PGPan Guo
Pan Guo
ZiHe GaoZiHe Gao
ZiHe Gao
This research focuses on the impact of smoke exhaust volume and smoke vent layout, which are two crucial factors affecting the smoke control efficiency in tunnels, on the smoke exhaust effect in tunnel fires. Numerical simulation methods are employed to investigate the impact of changing the smoke exhaust volume and the smoke vent number on the smoke exhaust performance in a curved tunnel with a ceiling centralized smoke exhaust system. This research primarily examines the length of the smoke distribution, the smoke temperature under the ceiling, the vertical visibility, and the exhausted smoke mass flow rate. The findings indicate that, in a tunnel with a single-side ceiling centralized smoke exhaust mode, an imbalance in smoke distribution occurs between the upstream and downstream of the fire source. The upstream area experiences a higher amount of smoke, while the downstream area has thinner smoke. Increasing the smoke exhaust volume yielded positive effects on smoke control, as evident in the reduced the smoke spread range, and improved the smoke exhaust efficiency. The influence of changing smoke vent number on the smoke exhaust effect was dependent on the smoke exhaust volume. When the smoke exhaust volume was excessive, altering the number of smoke vents had a minimal impact on smoke exhaust, while in cases with small smoke exhaust volumes, changes in smoke vent numbers obviously influenced the smoke control effect. Therefore, selecting an appropriate smoke exhaust volume and raising the smoke vent number can effectively optimize the performance of the ceiling centralized smoke exhaust system.

22 December 2023 in Indoor and Built Environment
Verified
Journal Article
Closed access
ZiHe GaoZiHe Gao
ZiHe Gao
PWPu Wang
Pu Wang
JCJiajun Cai
Jiajun Cai
MLMingge Liu
Mingge Liu
LLLinjie Li
Linjie Li
When there is a fire in a tunnel, the heat released by the combustion is difficult to dissipate and the temperature inside the tunnel would rise rapidly. Longitudinal ventilation (LV) has been commonly adopted as the smoke control strategy in tunnel fires, which is essential to safeguard the tunnel structure and the trapped people. Besides the smoke control method by LV, the water mist system (WMS) can provide a powerful cooling effect for the high-temperature smoke in the tunnel. This article aims to investigate the impact of WMS on the smoke back-layering (BL) length with LV and the mutual effect process between the smoke spread and the WMS. The findings show that the BL length is restricted more effectively by the combined action of water mist and LV. Upon activation of the WMS, the water mist’s effect inhibits the smoke’s ability to spread upstream and causes the smoke layer to settle down, which disturbs the stability of the smoke layer. An unstable layer of smoke is more likely to be blown downstream by longitudinal ventilation. All water mist particle diameters show a significant reduction in smoke back-layering with an increased flow rate. The BL length would gradually reduce as the particle diameter is decreased. The tendency of flow rate and particle diameter on the BL length shows similar effects to the critical velocity ( Vcr). The Vcr is reduced with the rising flow rate and increased with expanding particle diameter.