Hao-wei YAO

Prof. Dr. Hao-wei YAO


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2024 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
ZLZhen Lou
Zhen Lou
JHJunqi Huang
Junqi Huang
MWMin Wang
Min Wang
YZYang Zhang
Yang Zhang
KLKefeng Lv
Kefeng Lv
HYHao-wei YAO
Hao-wei YAO
Fire incidents in energy storage stations are frequent, posing significant firefighting safety risks. To simulate the fire characteristics and inhibition performances by fine water mist for lithium-ion battery packs in an energy-storage cabin, the PyroSim software is used to build a 1:1 experimental geometry model of a containerized lithium-ion energy storage cabin. The simulation reveals five stages and their characteristic parameter variations during a fire incident: initial temperature rise, flame generation, flame spread, stable combustion, and flame extinguishment. By adjusting various parameters of the fine water mist, the design of the fine water mist firefighting system for containerized energy storage units is optimized. The simulation results indicate that the optimal inhibition effect for the energy storage cabin's fine water mist firefighting system is achieved when the spray intensity is ≥24 l/min, the fog cone angle is 76°, nozzle velocity is 10 m/s, and the optimal particle size of the fine water mist is 50 μm. The research findings not only provide a rational method and theoretical guidance for the numerical simulation of thermal runaway in lithium batteries but also offer theoretical data support for the safety design and protection of future energy storage cabins.

13 September 2022 in Computational Intelligence and Neuroscience
Verified
Journal Article
Open access
PDF file
HYHao-wei YAO
Hao-wei YAO
KLKe-Feng Lv
Ke-Feng Lv
YLYou-Xin Li
You-Xin Li
JZJin-Guang Zhang
Jin-Guang Zhang
ZLZhong-Bin Lv
Zhong-Bin Lv
HQHeng-Jie Qin
Heng-Jie Qin
In this study, while aiming at the prevention of fire accidents in underground commercial streets, an underground commercial street is selected as a research object, and the building fire is numerically simulated using the PyroSim software. Fire simulation scenarios are divided according to different fire zones by analyzing the temperature, carbon monoxide (CO) concentration, and visibility in the smoke layer inside a building. The available safe evacuation time is calculated according to the critical fire hazard judgment conditions. We found that the time when the flue gas temperature and CO concentration reached the critical value in the fire site was longer than the time when the visibility reached the critical value reducing or even avoiding the spread of smoke from the fire area to the evacuation stairs can provide effective help for crowd evacuation. Finally, the safety of the building is evaluated, and fire prevention countermeasures are defined based on the actual situation and fire numerical simulation results to reduce fire incidence, casualties, and economic losses.

29 December 2022 in Buildings
Verified
Journal Article
Open access
PDF file
XWXiaoge Wei
Xiaoge Wei
YZYinlong Zhao
Yinlong Zhao
LLLiping Lian
Liping Lian
HYHao-wei YAO
Hao-wei YAO
HSHuaitao Song
Huaitao Song
HQHengjie Qin
Hengjie Qin
In order to cope with limited land availability and the increasing urban population, more high-rise buildings are being built throughout cities, but this has also led to new challenges in the emergency evacuation of people. Therefore, we conducted an evacuation experiment of a group of people in the stairwells of high-rise buildings to explore the movement law of groups in stairwells. The experiment had 18 scenes, including the evacuation movement of an independent group and the crowd evacuation movement of different groups. Analyzing the independent groups’ movement showed that regardless of the type of group, the average speed of the crowd was more than 1.2 m/s, which was longer than that of previous studies. The more constraints in the evacuation process, the smaller the speed difference between males and females. Group cohesion was mostly concentrated at about 1 s. Moreover, group velocity and cohesion were found to have no significant correlation in stairwell movement. Analyzing the crowd evacuation time of eight different scenes showed that it took longer for crowds bearing weight to evacuate than those not bearing weight. According to the spatiotemporal evolution of crowd evacuation in stairwells, the crowd moves intermittently in the evacuation process, especially in the early and middle stages of evacuation, and the influence of group factors on this process was not obvious. Regardless of the kind of scene or stairwell, the number of pedestrians generally first increased and then decreased to a significantly low value, and the number of pedestrians reached about 30 in the scenario of people without any load. Additionally, the speed of the pedestrians entering the stairwell in the back of the group was not faster than that of the pedestrians in the front, which showed that pedestrians rarely engaged in overtaking behavior. The research results of this paper not only enrich evacuation research but also provide support for the design of high-rise stairs.

8 April 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ZBZ. P. BAI
Z. P. BAI
HYHao-wei YAO
Hao-wei YAO
HZH. H. Zhang
H. H. Zhang
The fire characteristics under natural ventilation in the cable compartment of the utility tunnel are studied. A series of small-scale fire experimental tests are conducted to obtain the maximum temperature below the ceiling of different ignition vertical heights and cable types. In this paper, the ceiling temperature decay and heat release rate (HRR) are studied in the cable compartment of utility tunnel. Through experimental tests, the fire characteristics of placing the fire source on the near wall side 3.0 m away from the shaft of the utility tunnel cable compartment are studied. The results showed that under the action of natural ventilation, with the decrease of fuel quantity, the mass loss of cable decreases, and the maximum temperature below the ceiling of the cable compartment in the utility tunnel decreases. ZRYJV cables burn more sufficient combustion than RVVR cables. A new empirical association for total HRR is proposed. Those experimental test results are used as validation data for the newly proposed empirical correlation of total HRR. This paper hopes to provide some basic fire safety references for the utility tunnel planning of the urban underground cable compartment.

15 June 2023 in Fire
Verified
Journal Article
Open access
PDF file
HSHuaitao Song
Huaitao Song
HYHao-wei YAO
Hao-wei YAO
XWXiaoge Wei
Xiaoge Wei
HQHengjie Qin
Hengjie Qin
YLYouxin Li
Youxin Li
QCQianlong Chen
Qianlong Chen
Fire accidents due to oil-immersed transformers seriously threaten the safe operation of power systems. In this paper, the similarity principle was used to design a high-pressure water mist fire-extinguishing test platform for a small-scale transformer fire, and the design method achieved a good fire extinguishing effect. The results indicate that a deflagration phenomenon, lasting about 2–4 s, could be observed after activating the high-pressure water mist system; the flame temperature rose rapidly at first, then dropped sharply, and finally cooled to the indoor temperature. The nozzle’s flow rate in this system has a significant impact on the fire extinguishing time. Meanwhile, the adjustment of the upper nozzle height also influenced the fire suppression effectiveness of the system, where a height of 1800 mm achieved the best performance compared to the others. In addition, the ambient wind speed is a very unfavorable factor for transformer fire suppression, where the fire extinguishing efficiency decreases rapidly with the increase in wind speed. Therefore, under low wind speed conditions, the high-pressure water mist system has great advantages in the fire suppression of outdoor oil-immersed transformers, and the above research results can provide a reference for the optimization design of this system.

12 May 2023 in Fire
Verified
Journal Article
Open access
PDF file
HQHengjie Qin
Hengjie Qin
JWJiangqi Wen
Jiangqi Wen
ZiHe GaoZiHe Gao
ZiHe Gao
LClingling chai
lingling chai
HYHao-wei YAO
Hao-wei YAO
Real-time acquisition and visualization of temperature anomalies in building spaces and 3D temperature field data during fires are of vital importance for fire danger warnings, early rescue operations, evacuation commands, and subsequent fire accident investigations. Taking into account the non-contact, global (planar and spatial), and high efficiency advantages of acoustic CT temperature measurement technology, this study involved the conducting of exploratory preliminary research in order to provide new ideas for the real-time global perception of information on building fires. The detailed research objective was as follows: obtain the temperature data at any time of a fire based on Fire Dynamics Simulator (FDS) and fit them to form the base temperature distribution diagram at that time. The large ill-conditioned matrix equation of acoustic flight under the scheme of multi-grid division was then constructed. The discrete temperature data of each grid in the building space was obtained by solving the matrix equation based on algebraic reconstruction algorithm (ART) and joint algebraic reconstruction algorithm (SART). The three-dimensional temperature field reconstruction of building space was realized by the interpolation of discrete temperature data. The reconstruction effect of each scheme was evaluated through the error analysis between the reconstruction data and the basic data. The results show that the real-time reconstruction of a 3D temperature field of a building thermal field can be realized based on acoustic CT temperature measurement technology, and the reconstruction algorithm and grid division scheme have a significant control effect on the reconstruction effect.