Javier Monroy

Dr. Javier Monroy

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JMJavier Monroy
Javier Monroy
VBVictor Hernandez Bennetts
Victor Hernandez Bennetts
HFHan Fan
Han Fan
ALAchim J. Lilienthal
Achim J. Lilienthal
JGJavier Gonzalez-Jimenez
Javier Gonzalez-Jimenez
This work presents a simulation framework developed under the widely used Robot Operating System (ROS) to enable the validation of robotics systems and gas sensing algorithms under realistic environments. The framework is rooted in the principles of computational fluid dynamics and filament dispersion theory, modeling wind flow and gas dispersion in 3D real-world scenarios (i.e., accounting for walls, furniture, etc.). Moreover, it integrates the simulation of different environmental sensors, such as metal oxide gas sensors, photo ionization detectors, or anemometers. We illustrate the potential and applicability of the proposed tool by presenting a simulation case in a complex and realistic office-like environment where gas leaks of different chemicals occur simultaneously. Furthermore, we accomplish quantitative and qualitative validation by comparing our simulated results against real-world data recorded inside a wind tunnel where methane was released under different wind flow profiles. Based on these results, we conclude that our simulation framework can provide a good approximation to real world measurements when advective airflows are present in the environment.

7 June 2011 in Sensors
Verified
Journal Article
Open access
PDF file
JGJavier Gonzalez-Jimenez
Javier Gonzalez-Jimenez
JMJavier Monroy
Javier Monroy
JBJose Luis Blanco-Claraco
Jose Luis Blanco-Claraco
One of the major disadvantages of the use of Metal Oxide Semiconductor (MOS) technology as a transducer for electronic gas sensing devices (e-noses) is the long recovery period needed after each gas exposure. This severely restricts its usage in applications where the gas concentrations may change rapidly, as in mobile robotic olfaction, where allowing for sensor recovery forces the robot to move at a very low speed, almost incompatible with any practical robot operation. This paper describes the design of a new e-nose which overcomes, to a great extent, such a limitation. The proposed e-nose, called Multi-Chamber Electronic Nose (MCE-nose), comprises several identical sets of MOS sensors accommodated in separate chambers (four in our current prototype), which alternate between sensing and recovery states, providing, as a whole, a device capable of sensing changes in chemical concentrations faster. The utility and performance of the MCE-nose in mobile robotic olfaction is shown through several experiments involving rapid sensing of gas concentration and mobile robot gas mapping.

11 October 2012 in Sensors
Verified
Journal Article
Open access
PDF file
JMJavier Monroy
Javier Monroy
JGJavier Gonzalez-Jimenez
Javier Gonzalez-Jimenez
JBJose Luis Blanco-Claraco
Jose Luis Blanco-Claraco
Metal Oxide Semiconductor (MOX) gas transducers are one of the preferable technologies to build electronic noses because of their high sensitivity and low price. In this paper we present an approach to overcome to a certain extent one of their major disadvantages: their slow recovery time (tens of seconds), which limits their suitability to applications where the sensor is exposed to rapid changes of the gas concentration. Our proposal consists of exploiting a double first-order model of the MOX-based sensor from which a steady-state output is anticipated in real time given measurements of the transient state signal. This approach assumes that the nature of the volatile is known and requires a precalibration of the system time constants for each substance, an issue that is also described in the paper. The applicability of the proposed approach is validated with several experiments in real, uncontrolled scenarios with a mobile robot bearing an e-nose.

8 May 2015 in Autonomous Robots
Verified
Journal Article
Closed access
PDF file
JMJavier Monroy
Javier Monroy
JBJose-Luis Blanco
Jose-Luis Blanco
JGJavier Gonzalez-Jimenez
Javier Gonzalez-Jimenez

1 May 2016
Verified
Conference Paper
Closed access
MJMariano Jaimez
Mariano Jaimez
JMJavier Monroy
Javier Monroy
JGJavier Gonzalez-Jimenez
Javier Gonzalez-Jimenez
In this paper we present a fast and precise method to estimate the planar motion of a lidar from consecutive range scans. For every scanned point we formulate the range flow constraint equation in terms of the sensor velocity, and minimize a robust function of the resulting geometric constraints to obtain the motion estimate. Conversely to traditional approaches, this method does not search for correspondences but performs dense scan alignment based on the scan gradients, in the fashion of dense 3D visual odometry. The minimization problem is solved in a coarse-to-fine scheme to cope with large displacements, and a smooth filter based on the covariance of the estimate is employed to handle uncertainty in unconstraint scenarios (e.g. corridors). Simulated and real experiments have been performed to compare our approach with two prominent scan matchers and with wheel odometry. Quantitative and qualitative results demonstrate the superior performance of our approach which, along with its very low computational cost (0.9 milliseconds on a single CPU core), makes it suitable for those robotic applications that require planar odometry. For this purpose, we also provide the code so that the robotics community can benefit from it.

4 February 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
POPepe Ojeda
Pepe Ojeda
JMJavier Monroy
Javier Monroy
JGJavier Gonzalez-Jimenez
Javier Gonzalez-Jimenez
Gas source localization (GSL) by an olfactory robot is a research field with a great potential for applications but also with numerous unsolved challenges, particularly when the search must take place in realistic, indoor environments that feature obstacles and turbulent airflows. In this work, we present a new probabilistic GSL method for a terrestrial mobile robot that revolves around the propagation of local estimations throughout the environment. By exploiting the geometry of the environment as the basis for this propagation, we avoid relying on analytical dispersion models, eliminating the need to assume controlled environmental conditions. Simulated and real experiments are presented in different indoor environments featuring multiple rooms and turbulent flows, demonstrating the suitability of our approach for locating the emitting gas source.