Elmar Laistler

Dr. Elmar Laistler

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2017 in Frontiers in Physics
Verified
Journal Article
Open access
EMEwald Moser
Ewald Moser
ELElmar Laistler
Elmar Laistler
FSFranz Schmitt
Franz Schmitt
GKGeorg Kontaxis
Georg Kontaxis
"History, of course, is difficult to write, if for no other reason, than that it has so many players and so many authors." – P. J. Keating (former Australian Prime Minister) Starting with post-war developments in nuclear magnetic resonance (NMR) a race for stronger and stronger magnetic fields has begun in the 1950s to overcome the inherently low sensitivity of this promising method. Further challenges were larger magnet bores to accommodate small animals and eventually humans. Initially, resistive electromagnets with small pole distances, or sample volumes, and field strengths up to 2.35 T (or 100 MHz 1H frequency) were used in applications in physics, chemistry, and material science. This was followed by stronger and more stable (NbTi based) superconducting magnet technology typically implemented first for small-bore systems in analytical chemistry, biochemistry and structural biology, and eventually allowing larger horizontal-bore magnets with diameters large enough to fit small laboratory animals. By the end of the 1970s, first low-field resistive magnets big enough to accommodate humans were developed and superconducting whole-body systems followed. Currently, cutting-edge analytical NMR systems are available at proton frequencies up to 1 GHz (23.5 T) based on Nb3Sn at 1.9 K. A new 1.2 GHz system (28 T) at 1.9 K, operating in persistent mode but using a combination of low and high temperature multi-filament superconductors is to be released. Preclinical instruments range from small-bore animal systems with typically 600 - 800 MHz (14.1 - 18.8 T) up to 900 MHz (21 T) at 1.9 K. Human whole-body MRI systems currently operate up to 10.5 T. Hybrid combined superconducting and resistive electromagnets with even higher field strength of 45 T dc and 100 T pulsed, are available for material research, of course with smaller free bore diameters. This rather costly development towards higher and higher field strength is a consequence of the inherently low and, thus, urgently needed sensitivity in all NMR experiments. This review particularly describes and compares the developments in superconducting magnet technology and, thus, sensitivity in three fields of research: analytical NMR, biomedical and preclinical research, and human MRI and MRS, highlighting important steps and

24 November 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
LLLucia Navarro de Lara
Lucia Navarro de Lara
Christian WindischbergerChristian Windischberger
Christian Windischberger
Andre KuehneAndre Kuehne
Andre Kuehne
MWMichael Woletz
Michael Woletz
JSJürgen Sieg
Jürgen Sieg
ELElmar Laistler
Elmar Laistler
Purpose: To overcome current limitations in combined transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) studies by employing a dedicated coil array design for 3 Tesla.Methods: The state‐of‐the‐art setup for concurrent TMS/fMRI is to use a large birdcage head coil, with the TMS between the subject's head and the MR coil. This setup has drawbacks in sensitivity, positioning, and available imaging techniques. In this study, an ultraslim 7‐channel receive‐only coil array for 3 T, which can be placed between the subject's head and the TMS, is presented. Interactions between the devices are investigated and the performance of the new setup is evaluated in comparison to the state‐of‐the‐art setup.Results: MR sensitivity obtained at the depth of the TMS stimulation is increased by a factor of five. Parallel imaging with an acceleration factor of two is feasible with low g‐factors. Possible interactions between TMS and the novel hardware were investigated and were found negligible.Conclusion: The novel coil array is safe, strongly improves signal‐to‐noise ratio in concurrent TMS/fMRI experiments, enables parallel imaging, and allows for flexible positioning of the TMS on the head while ensuring efficient TMS stimulation due to its ultraslim design. Magn Reson Med 74:1492–1501, 2015. © 2014 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

1 April 2017 in NeuroImage
Verified
Journal Article
Closed access
LLLucia Navarro de Lara
Lucia Navarro de Lara
MTMartin Tik
Martin Tik
MWMichael Woletz
Michael Woletz
RFRoberta Frass-Kriegl
Roberta Frass-Kriegl
EMEwald Moser
Ewald Moser
Christian WindischbergerChristian Windischberger
Christian Windischberger

13 January 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
LNLena Nohava
Lena Nohava
RCRaphaela Czerny
Raphaela Czerny
SRSigrun Roat
Sigrun Roat
MOMichael Obermann
Michael Obermann
AKAndre Kuehne
Andre Kuehne
ELElmar Laistler
Elmar Laistler
Magnetic resonance has become a backbone of medical imaging but suffers from inherently low sensitivity. This can be alleviated by improved radio frequency (RF) coils. Multi-turn multi-gap coaxial coils (MTMG-CCs) introduced in this work are flexible, form-fitting RF coils extending the concept of the single-turn single-gap CC by introducing multiple cable turns and/or gaps. It is demonstrated that this enables free choice of the coil diameter, and thus, optimizing it for the application to a certain anatomical site, while operating at the self-resonance frequency. An equivalent circuit for MTMG-CCs is modeled to predict their resonance frequency. Possible configurations regarding size, number of turns and gaps, and cable types for different B 0 field strengths are calculated. Standard copper wire loop coils (SCs) and flexible CCs made from commercial coaxial cable were fabricated as receive-only coils for 3 T and transmit/receive coils at 7 T with diameters between 4 and 15 cm. Electromagnetic simulations are used to investigate the currents on MTMG-CCs, and demonstrate comparable specific absorption rate of 7 T CCs and SCs. Signal-to-noise ratio (SNR), transmit efficiency, and active detuning performance of CCs were compared in bench tests and MR experiments. For the form-fitted receive-only CCs at 3 T no significant SNR degradation was found as compared to flat SCs on a balloon phantom. Form-fitted transmit/receive CCs at 7 T showed higher transmit efficiency and SNR. MTMG-CCs can be sized to optimize sensitivity, are flexible and lightweight, and could therefore enable the fabrication of wearable coils with improved patient comfort.

26 August 2016 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GFGeorg B. Fiedler
Georg B. Fiedler
ASAlbrecht I. Schmid
Albrecht I. Schmid
SGSigrun Goluch
Sigrun Goluch
KSKiril Schewzow
Kiril Schewzow
ELElmar Laistler
Elmar Laistler
MMMartin Meyerspeer
Martin Meyerspeer
31P magnetic resonance spectroscopy (MRS) is widely used for non-invasive investigation of muscle metabolism dynamics. This study aims to extend knowledge on parameters derived from these measurements in detail and comprehensiveness: proton (H+) efflux, buffer capacity and the contributions of glycolytic (L) and oxidative (Q) rates to ATP synthesis were calculated from the evolutions of phosphocreatine (PCr) and pH. Data are reported for two muscles in the human calf, for each subject and over a wide range of exercise intensities. 22 subjects performed plantar flexions in a 7T MR-scanner, leading to PCr changes ranging from barely noticeable to almost complete depletion, depending on exercise protocol and muscle studied by localized MRS. Cytosolic buffer capacity was quantified for the first time non-invasively and individually, as was proton efflux evolution in early recovery. Acidification started once PCr depletion reached 60–75%. Initial and end-exercise L correlated with end-exercise levels of PCr and approximately linear with pH. Q calculated directly from PCr and pH derivatives was plausible, requiring fewer assumptions than the commonly used ADP-model. In conclusion, the evolution of parameters describing cellular energy metabolism was measured over a wide range of exercise intensities, revealing a relatively complete picture of muscle metabolism.

9 July 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
SGSigrun Goluch
Sigrun Goluch
Andre KuehneAndre Kuehne
Andre Kuehne
MMMartin Meyerspeer
Martin Meyerspeer
RFRoberta Frass-Kriegl
Roberta Frass-Kriegl
ASAlbrecht I. Schmid
Albrecht I. Schmid
ELElmar Laistler
Elmar Laistler