Roberta Frass-Kriegl

Dr. Roberta Frass-Kriegl

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2017 in NeuroImage
Verified
Journal Article
Closed access
LLLucia Navarro de Lara
Lucia Navarro de Lara
MTMartin Tik
Martin Tik
MWMichael Woletz
Michael Woletz
RFRoberta Frass-Kriegl
Roberta Frass-Kriegl
EMEwald Moser
Ewald Moser
Christian WindischbergerChristian Windischberger
Christian Windischberger

13 January 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
LNLena Nohava
Lena Nohava
RCRaphaela Czerny
Raphaela Czerny
SRSigrun Roat
Sigrun Roat
MOMichael Obermann
Michael Obermann
AKAndre Kuehne
Andre Kuehne
ELElmar Laistler
Elmar Laistler
Magnetic resonance has become a backbone of medical imaging but suffers from inherently low sensitivity. This can be alleviated by improved radio frequency (RF) coils. Multi-turn multi-gap coaxial coils (MTMG-CCs) introduced in this work are flexible, form-fitting RF coils extending the concept of the single-turn single-gap CC by introducing multiple cable turns and/or gaps. It is demonstrated that this enables free choice of the coil diameter, and thus, optimizing it for the application to a certain anatomical site, while operating at the self-resonance frequency. An equivalent circuit for MTMG-CCs is modeled to predict their resonance frequency. Possible configurations regarding size, number of turns and gaps, and cable types for different B 0 field strengths are calculated. Standard copper wire loop coils (SCs) and flexible CCs made from commercial coaxial cable were fabricated as receive-only coils for 3 T and transmit/receive coils at 7 T with diameters between 4 and 15 cm. Electromagnetic simulations are used to investigate the currents on MTMG-CCs, and demonstrate comparable specific absorption rate of 7 T CCs and SCs. Signal-to-noise ratio (SNR), transmit efficiency, and active detuning performance of CCs were compared in bench tests and MR experiments. For the form-fitted receive-only CCs at 3 T no significant SNR degradation was found as compared to flat SCs on a balloon phantom. Form-fitted transmit/receive CCs at 7 T showed higher transmit efficiency and SNR. MTMG-CCs can be sized to optimize sensitivity, are flexible and lightweight, and could therefore enable the fabrication of wearable coils with improved patient comfort.

9 July 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
SGSigrun Goluch
Sigrun Goluch
Andre KuehneAndre Kuehne
Andre Kuehne
MMMartin Meyerspeer
Martin Meyerspeer
RFRoberta Frass-Kriegl
Roberta Frass-Kriegl
ASAlbrecht I. Schmid
Albrecht I. Schmid
ELElmar Laistler
Elmar Laistler

1 November 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
RFRoberta Frass-Kriegl
Roberta Frass-Kriegl
LLLucia Isabel Navarro de Lara
Lucia Isabel Navarro de Lara
MPMichael Pichler
Michael Pichler
JSJürgen Sieg
Jürgen Sieg
EMEwald Moser
Ewald Moser
ELElmar Laistler
Elmar Laistler
The purpose of this work is the design, implementation and evaluation of a mechanically flexible receive-only coil array for magnetic resonance imaging (MRI) at 3 T that can be applied to various target organs and provides high parallel imaging performance. A 23-channel array was designed based on a rigid-flex printed circuit board (PCB). The flexible multi-layer part contains the copper traces forming the coil elements. The rigid part of the PCB houses the solder joints and lumped elements. The coil housing consists of rigid caps mounted above the rigid parts. Adhesive PTFE sheets cover all flexible parts. The developed array was tested on the bench as well as in phantom and in vivo MRI experiments employing parallel imaging acceleration factors up to six. Efficient mutual decoupling between receive elements and detuning between receive array and body coil was achieved. An increased signal-to-noise ratio in comparison to commercial reference coils is demonstrated, especially in regions close to the developed array and for high parallel imaging acceleration factors. Exemplary in vivo images of head, ankle, knee, shoulder and hand are presented. Based on high sensitivity close to the array and low g-factors, this flexible coil is well suited for studies of occipital and temporal cortex, as well as musculoskeletal targets like knee, ankle, elbow and wrist.

17 April 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
RFRoberta Frass-Kriegl
Roberta Frass-Kriegl
JGJean‐Christophe Ginefri
Jean‐Christophe Ginefri
MPMarie Poirier‐Quinot
Marie Poirier‐Quinot
LDLuc Darrasse
Luc Darrasse
SGSigrun Goluch
Sigrun Goluch
ELElmar Laistler
Elmar Laistler

10 March 2017 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
ELElmar Laistler
Elmar Laistler
BDBarbara Dymerska
Barbara Dymerska
JSJürgen Sieg
Jürgen Sieg
SGSigrun Goluch
Sigrun Goluch
RFRoberta Frass-Kriegl
Roberta Frass-Kriegl
EMEwald Moser
Ewald Moser
Purpose: To demonstrate a dedicated setup for ultrahigh resolution MR imaging of the human finger in vivo.Methods: A radiofrequency coil was designed for optimized signal homogeneity and sensitivity in the finger at ultrahigh magnetic field strength (7 T), providing high measurement sensitivity. Imaging sequences (2D turbo‐spin echo (TSE) and 3D magnetization‐prepared rapid acquisition gradient echo (MPRAGE)) were adapted for high spatial resolution and good contrast of different tissues in the finger, while keeping acquisition time below 10 minutes. Data was postprocessed to display finger structures in three dimensions.Results: 3D MPRAGE data with isotropic resolution of 200 µm, along with 2D TSE images with in‐plane resolutions of 58 × 78 µm2 and 100 × 97 µm2, allowed clear identification of various anatomical features such as bone and bone marrow, tendons and annular ligaments, cartilage, arteries and veins, nerves, and Pacinian corpuscles.Conclusion: Using this dedicated finger coil at 7 T, together with adapted acquisition sequences, it is possible to depict the internal structures of the human finger in vivo within patient‐compatible measurement time. It may serve as a tool for diagnosis and treatment monitoring in pathologies ranging from inflammatory or erosive joint diseases to injuries of tendons and ligaments to nervous or vascular disorders in the finger. Magn Reson Med 79:588–592, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.