Andre Kuehne

Dr. Andre Kuehne

MRI.TOOLS GmbH
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2015 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
COCelal Oezerdem
Celal Oezerdem
LWLukas Winter
Lukas Winter
AGAndreas Graessl
Andreas Graessl
KPKatharina Paul
Katharina Paul
AEAntje Els
Antje Els
Thoralf NiendorfThoralf Niendorf
Thoralf Niendorf
Purpose: To design, evaluate, and apply a bow tie antenna transceiver radiofrequency (RF) coil array tailored for cardiac MRI at 7.0 Tesla (T).Methods: The radiofrequency (RF) coil array comprises 16 building blocks each containing a bow tie shaped λ/2‐dipole antenna. Numerical simulations were used for transmission field homogenization and RF safety validation. RF characteristics were examined in a phantom study. The array's suitability for high spatial resolution two‐dimensional (2D) CINE imaging and for real time imaging of the heart was examined in a volunteer study.Results: The arrays transmission fields and RF characteristics are suitable for cardiac MRI at 7.0T. The coil performance afforded a spatial resolution as good as (0.8 × 0.8 × 2.5) mm3 for segmented 2D CINE MRI at 7.0T which is by a factor of 12 superior versus standardized protocols used in clinical practice at 1.5T. The proposed transceiver array supports 1D acceleration factors of up to R = 6 without impairing image quality significantly.Conclusion: The 16‐channel bow tie antenna transceiver array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0 Tesla. Magn Reson Med 75:2553–2565, 2016.

7 March 2017 in British Journal of Radiology
Verified
Journal Article
Open access
BHBrian F Hutton
Brian F Hutton
MOMichele Occhipinti
Michele Occhipinti
Andre KuehneAndre Kuehne
Andre Kuehne
DMDomokos Mathe
Domokos Mathe
NKNoémi Kovács
Noémi Kovács
OCOn behalf of the INSERT consortium
On behalf of the INSERT consortium
There is increasing clinical use of combined positron emission tomography and MRI, but to date there has been no clinical system developed capable of simultaneous single-photon emission computed tomography (SPECT) and MRI. There has been development of preclinical systems, but there are several challenges faced by researchers who are developing a clinical prototype including the need for the system to be compact and stationary with MRI-compatible components. The limited work in this area is described with specific reference to the Integrated SPECT/MRI for Enhanced stratification in Radio-chemo Therapy (INSERT) project, which is at an advanced stage of developing a clinical prototype. Issues of SPECT/MRI compatibility are outlined and the clinical appeal of such a system is discussed, especially in the management of brain tumour treatment.

24 November 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
LLLucia Navarro de Lara
Lucia Navarro de Lara
Christian WindischbergerChristian Windischberger
Christian Windischberger
Andre KuehneAndre Kuehne
Andre Kuehne
MWMichael Woletz
Michael Woletz
JSJürgen Sieg
Jürgen Sieg
ELElmar Laistler
Elmar Laistler
Purpose: To overcome current limitations in combined transcranial magnetic stimulation (TMS) and functional magnetic resonance imaging (fMRI) studies by employing a dedicated coil array design for 3 Tesla.Methods: The state‐of‐the‐art setup for concurrent TMS/fMRI is to use a large birdcage head coil, with the TMS between the subject's head and the MR coil. This setup has drawbacks in sensitivity, positioning, and available imaging techniques. In this study, an ultraslim 7‐channel receive‐only coil array for 3 T, which can be placed between the subject's head and the TMS, is presented. Interactions between the devices are investigated and the performance of the new setup is evaluated in comparison to the state‐of‐the‐art setup.Results: MR sensitivity obtained at the depth of the TMS stimulation is increased by a factor of five. Parallel imaging with an acceleration factor of two is feasible with low g‐factors. Possible interactions between TMS and the novel hardware were investigated and were found negligible.Conclusion: The novel coil array is safe, strongly improves signal‐to‐noise ratio in concurrent TMS/fMRI experiments, enables parallel imaging, and allows for flexible positioning of the TMS on the head while ensuring efficient TMS stimulation due to its ultraslim design. Magn Reson Med 74:1492–1501, 2015. © 2014 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

9 July 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
SGSigrun Goluch
Sigrun Goluch
Andre KuehneAndre Kuehne
Andre Kuehne
MMMartin Meyerspeer
Martin Meyerspeer
RFRoberta Frass-Kriegl
Roberta Frass-Kriegl
ASAlbrecht I. Schmid
Albrecht I. Schmid
ELElmar Laistler
Elmar Laistler

15 February 2013 in Scientific Reports
Verified
Journal Article
Open access
HWHelmar Waiczies
Helmar Waiczies
SLStefano Lepore
Stefano Lepore
SDSusanne Drechsler
Susanne Drechsler
FQFatimunnisa Qadri
Fatimunnisa Qadri
BPBettina Purfürst
Bettina Purfürst
SWSonia Waiczies
Sonia Waiczies
Magnetic resonance imaging (MRI) provides the opportunity of tracking cells in vivo. Major challenges in dissecting cells from the recipient tissue and signal sensitivity constraints albeit exist. In this study, we aimed to tackle these limitations in order to study inflammation in autoimmune encephalomyelitis. We constructed a very small dual-tunable radio frequency (RF) birdcage probe tailored for 19F (fluorine) and 1H (proton) MR mouse neuroimaging. The novel design eliminated the need for extra electrical components on the probe structure and afforded a uniform -field as well as good SNR. We employed fluorescently-tagged 19F nanoparticles and could study the dynamics of inflammatory cells between CNS and lymphatic system during development of encephalomyelitis, even within regions of the brain that are otherwise not easily visualized by conventional probes. 19F/1H MR Neuroimaging will allow us to study the nature of immune cell infiltration during brain inflammation over an extensive period of time.

16 October 2014 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
Andre KuehneAndre Kuehne
Andre Kuehne
SGSigrun Goluch
Sigrun Goluch
PWPatrick Waxmann
Patrick Waxmann
FSFrank Seifert
Frank Seifert
BIBernd Ittermann
Bernd Ittermann
ELElmar Laistler
Elmar Laistler