Gionata Fragomeni

Prof. Gionata Fragomeni

Magna Graecia University, Catanzaro, Calabria, Italy
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2015 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
MCMaria Vittoria Caruso
Maria Vittoria Caruso
VGVera Gramigna
Vera Gramigna
MRMichele Rossi
Michele Rossi
GSGiuseppe Filiberto Serraino
Giuseppe Filiberto Serraino
ARAttilio Renzulli
Attilio Renzulli
Gionata FragomeniGionata Fragomeni
Gionata Fragomeni

20 June 2018 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
GAGiuseppina Ambrogio
Giuseppina Ambrogio
GPG. Palumbo
G. Palumbo
ESE. Sgambitterra
E. Sgambitterra
PGP. Guglielmi
P. Guglielmi
APA. Piccininni
A. Piccininni
Gionata FragomeniGionata Fragomeni
Gionata Fragomeni

1 July 2011 in ASAIO Journal
Verified
Journal Article
Closed access
CBCarmine De Bartolo
Carmine De Bartolo
ANAlessandra Nigro
Alessandra Nigro
Gionata FragomeniGionata Fragomeni
Gionata Fragomeni
FCFrancesco M. Colacino
Francesco M. Colacino
DWDongfang Wang
Dongfang Wang
JZJoseph Zwischenberger
Joseph Zwischenberger
An experimental and numerical analysis was performed for the Wang-Zwische double-lumen cannula (DLC) (Avalon Elite). The aim of this work was to provide insight for future improvement by characterizing the fluid dynamic behavior of the novel catheter with metrics often associated with blood trauma. Pressure and flow distributions were measured on a steady-flow rig using a 50% glycerol-water mixture by imposing a 2 L/min flow rate across the drainage and infusion lumens. The fluid was modeled as Newtonian with density of 1050 kg/m3 and dynamic viscosity of 0.0035 kg/m·s. Reynolds numbers typical for transitional flow (Re = 2000–2500) were computed within the lumens because of the changing cross-sections of the cannula geometry. Numerical computations were performed using the steady three-dimensional Reynolds-averaged Navier-Stokes (RANS) equations and the low-Reynolds k-ω turbulence model. Discretization of governing equations was based on a cell-centered finite volume method. Numerical results correlated well with global performance of the cannula, allowing evaluation of the geometry toward potential blood trauma. Peak wall shear stress (WSS) in the drainage lumen was higher than that of infusion lumen, mainly due to the presence of side holes. Furthermore, recirculation regions were predicted in transition tubing to connectors of both the drainage and the infusion lumens because of adverse pressure gradients caused by the sudden enlargement of the cannula geometry. In this three-dimensional computational fluid dynamics (CFD) study, we observed higher peak WSS values for the drainage lumen, which may potentially cause blood trauma. Furthermore, recirculation regions were predicted in the proximity of the exit sections of both the infusion and drainage lumens, which may contribute to thrombosis formation. This study provides insight for future DLC modifications in minimizing cannula-induced blood trauma and thrombogenicity in long-term applications.

1 January 2016 in Biocybernetics and Biomedical Engineering
Verified
Journal Article
Closed access
RMRosario Mazzitelli
Rosario Mazzitelli
FBFergal Boyle
Fergal Boyle
EMEoin Murphy
Eoin Murphy
ARAttilio Renzulli
Attilio Renzulli
Gionata FragomeniGionata Fragomeni
Gionata Fragomeni

1 January 2017 in Procedia Engineering
Verified
Journal Article
Open access
GAGiuseppina Ambrogio
Giuseppina Ambrogio
ESEmanuele Sgambitterra
Emanuele Sgambitterra
Luigi De NapoliLuigi De Napoli
Luigi De Napoli
FGFrancesco Gagliardi
Francesco Gagliardi
Gionata FragomeniGionata Fragomeni
Gionata Fragomeni
TVTomaso M. Villa
Tomaso M. Villa
Titanium and its alloys are widely used in cranioplasty because they are biocompatible with excellent mechanical properties and favor the osseointegration with the bone. However, when Titanium alloys have to be worked several problems occurred from a manufacturing point of view: the standard procedure for obtaining Titanium prostheses is represented by the machining processes, which result time and cost consuming. The aim of this research consist to introduce alternative flexible sheet forming processes, i.e. Super Plastic Forming (SPF) and Single Point Incremental Forming (SPIF), for the manufacturing of patient-oriented titanium prostheses. The research activities have already highlighted the potentiality of the investigated forming processes that can be alternatively used taking into account both the damage morphology and the need of urgency operation. In the present work, the way of manufacturing the Ti prostheses by SPF and SPIF is described. A comparative analysis has been performed, thus highlighting the peculiarities of the investigated processes and the prostheses feasibility

1 December 2014 in Journal of Membrane Science
Verified
Journal Article
Closed access
INIlaria E. De Napoli
Ilaria E. De Napoli
Elisabetta ZanettiElisabetta Zanetti
Elisabetta Zanetti
Gionata FragomeniGionata Fragomeni
Gionata Fragomeni
EGErmenegildo Giuzio
Ermenegildo Giuzio
AAAlberto Audenino
Alberto Audenino
GCGerardo Catapano
Gerardo Catapano