9 July 2019 in Energies
Verified
Journal Article
Open access
PDF file
AMAlo Mikola
Alo Mikola
Raimo SimsonRaimo Simson
Raimo Simson
Jarek  KurnitskiJarek Kurnitski
Jarek Kurnitski
Single room ventilation units with heat recovery is one of the ventilation solutions that have been used in renovated residential buildings in Estonia. In multi-story buildings, especially in a cold climate, the performance of units is affected by the stack effect and wind-induced pressure differences between the indoor and the outdoor air. Renovation of the building envelope improves air tightness and the impact of the pressure conditions is amplified. The aim of this study was to predict the air pressure conditions in typical renovated multi-story apartment buildings and to analyze the performance of room-based ventilation units. The field measurements of air pressure differences in a renovated 5-story apartment building during the winter season were conducted and the results were used to simulate whole-year pressure conditions with IDA-ICE software. Performance of two types of single room ventilation units were measured in the laboratory and their suitability as ventilation renovation solutions was assessed with simulations. The results show that one unit stopped its operation as a heat recovery ventilator. In order to ensure satisfactory indoor climate and heat recovery using wall mounted units the pressure difference values were determined and proposed for correct design.

9 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
AHAnti Hamburg
Anti Hamburg
AMAlo Mikola
Alo Mikola
TPTuule Mall Parts
Tuule Mall Parts
TKTargo Kalamees
Targo Kalamees
Domestic hot water (DHW) system energy losses are an important part of energy consumption in newly built or in reconstructed apartment buildings. To reach nZEB or low energy building targets (renovation cases) we should take these losses into account during the design phase. These losses depend on room and water temperature, insulation and length of pipes and water circulation strategy. The target of our study is to develop a method which can be used in the early stages of design in primary energy calculations. We are also interested in how much of these losses cannot be utilised as internal heat gain and how much heat loss depends on the level of energy performance of the building. We used detailed DHW system heat loss measurements and simulations from an nZEB apartment building and annual heat loss data from a total of 22 apartment buildings. Our study showed that EN 15316-3 standard equations for pipe length give more than a twice the pipe length in basements. We recommend that for pipe length calculation in basements, a calculation based on the building’s gross area should be used and for pipe length in vertical shafts, a building’s heating area-based calculation should be used. Our study also showed that up to 33% of pipe heat losses can be utilised as internal heat gain in energy renovated apartment buildings but in unheated basements this figure drops to 30% and in shafts rises to 40% for an average loss (thermal pipe insulation thickness 40 mm) of 10.8 W/m and 5.1 W/m. Unutilised delivered energy loss from DHW systems in smaller apartment buildings can be up to 12.1 kWh/(m2·a) and in bigger apartment buildings not less than 5.5 kWh/(m2·a) (40 mm thermal pipe insulation).

27 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
AHAnti Hamburg
Anti Hamburg
ÜPÜlar Palmiste
Ülar Palmiste
AMAlo Mikola
Alo Mikola
TKTargo Kalamees
Targo Kalamees
Ensuring proper indoor air quality in high-rise apartment buildings is a crucial challenge, particularly when upgrading ventilation systems during deep energy renovation of existing buildings. This study evaluates the condition of existing ventilation systems and assesses the performance, cost, and energy efficiency of different mechanical ventilation solutions with heat recovery, including centralized and decentralized balanced ventilation with heat recovery, single-room ventilation units, and mechanical extract ventilation with heat pump heat recovery or without heat recovery. An onsite survey revealed significant deficiencies in existing ventilation systems, such as airtight window installations without dedicated fresh air valves, misaligned and decayed exhaust shafts, and inadequate extract airflow in kitchens and bathrooms. SWOT analyses for each system highlighted their strengths, weaknesses, opportunities, and threats, providing valuable insights for decision-makers. The results indicate that while centralized and decentralized mechanical ventilation with heat recovery enhances energy efficiency and indoor air quality in high-rise multifamily apartment buildings, challenges such as high installation costs, maintenance complexity, and architectural constraints must be addressed. Heat recovery with exhaust air heat pumps is a viable alternative for high-rise apartment buildings when more efficient options are not feasible.

15 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
PSPaula Sankelo
Paula Sankelo
KAKaiser Ahmed
Kaiser Ahmed
AMAlo Mikola
Alo Mikola
Jarek  KurnitskiJarek Kurnitski
Jarek Kurnitski
Finland has approximately 150,000 oil-heated private homes. In 2020, the Finnish government launched subsidies for private homeowner energy renovations. In this study, we examine the impact of two new energy renovation subsidies, the ELY grant and the ARA grant, from an energy efficiency point of view. Data from these subsidies reveal that a typical energy renovation case is a building from the 1970s where the oil boiler is replaced with an air-to-water heat pump. With additional data from the Finnish Energy certificate registry, a reference 1970s house is constructed and modelled in the building simulation programme, IDA ICE 4.8. Combinations of several renovation measures are simulated: air-to-water heat pump, ground-source heat pump, ventilation heat recovery and improved insulation. We found that resorting mainly to air-to-water heat pumps is not the most energy-effective solution. Ground-source heat pumps deliver a more significant reduction in delivered energy, especially with additional measures on insulation and heat recovery. Ground-source heat pumps also demand slightly less power than air-to-water heat pumps. Onsite solar PV generation helps supplement part of the power needed for heat pump solutions. Subsidy policies should emphasize deep renovation, ventilation heat recovery and onsite electricity generation.

29 March 2021 in E3S Web of Conferences
Verified
Conference Paper
Open access
PDF file
TKTuule Mall Kull
Tuule Mall Kull
AMAlo Mikola
Alo Mikola
ATAndres Tukia
Andres Tukia
AKAhmet Köse
Ahmet Köse
EPEduard Petlenkov
Eduard Petlenkov
MTMartin Thalfeldt
Martin Thalfeldt
The performance of ventilation heat recovery has high impact to the total energy consumption of modern buildings and its sub-optimal performance results in a remarkable energy penalty. There are several issues, which can significantly affect the heat recovery efficiency such as the inaccuracy of sensors, errors in control systems, mechanical defects and incorrect setting of the system. In addition, the direct comparison of the designed and measured heat recovery efficiency is not necessarily meaningful due to varying boundary conditions e.g. mass flow rates. The main focus of this paper is to develop and demonstrate a simple automated method for monitoring the heat recovery efficiency of ventilation units using building monitoring system (BMS). As the supply and extract air mass flows and temperatures may differ from the calculated initial design parameters, the proposed solution is to analyse the heat recovery efficiency using the number of transfer unit (NTU) method. With this method the efficiency is always calculated by the limiting mass flow, meaning that the warm exhaust air can not transfer more energy to the cold supply air than it is able to contain. As a result, the NTU method gives us the possibility to continuously compare the result to the temperature efficiency declared by the producer of the unit. The developed method demonstrated that the application of NTU method enables identifying sub-optimal performance of ventilation heat recovery, which would not have been revealed by direct comparison of temperature efficiencies. In some cases, low measured temperature efficiency was associated with problems not connected to the heat recovery heat exchanger. The method also enabled to estimate the additional heating costs due to the decreased heat recovery efficiency.