Andreas Fhager

Dr. Andreas Fhager

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2006 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AFAndreas Fhager
Andreas Fhager
PHParham Hashemzadeh
Parham Hashemzadeh
MPM. Persson
M. Persson
A tomographic time-domain reconstruction algorithm for solving the inverse electromagnetic problem is described. The application we have in mind is dielectric breast cancer detection but the results are of general interest to the field of microwave tomography. Reconstructions have been made from experimental and numerically simulated data for objects of different sizes in order to investigate the relation between the spectral content of the illuminating pulse and the quality of the reconstructed image. We have found that the spectral content is crucial for a successful reconstruction. The work has further shown that when imaging objects with different scale lengths it is an advantage to use a multiple step procedure. Low frequency content in the pulse is used to image the large structures and the reconstruction process then proceed by using higher frequency data to resolve small scale lengths. Good agreement between the results obtained from experimental data and simulated data has been achieved

1 January 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AFAndreas Fhager
Andreas Fhager
MGM. Gustafsson
M. Gustafsson
SNS. Nordebo
S. Nordebo
In this paper, quantitative dielectric image reconstruction based on broadband microwave measurements is investigated. A time-domain-based algorithm is derived where Debye model parameters are reconstructed in order to take into account the strong dispersive behavior found in biological tissue. The algorithm is tested with experimental and numerical data in order to verify the algorithm and to investigate improvements in the reconstructed image resulting from the improved description of the dielectric properties of the tissue when using broadband data. The comparison is made in relation to the more commonly used conductivity model. For the evaluation, two examples were considered, the first was a lossy saline solution and the second was less lossy tap water. Both liquids are strongly dispersive and used as a background medium in the imaging examples. The results show that the Debye model algorithm is of most importance in the tap water for a bandwidth of more than 1.5 GHz. Also the saline solution exhibits a dispersive behavior but since the losses restrict the useful bandwidth, the Debye model is of less significance even if somewhat larger and stronger artifacts can be seen in the conductivity model reconstructions.

1 September 2018 in Diagnostics
Verified
Journal Article
Open access
PDF file
TRTomas Rydholm
Tomas Rydholm
AFAndreas Fhager
Andreas Fhager
MPMikael Persson
Mikael Persson
SGShireen Geimer
Shireen Geimer
PMPaul Meaney
Paul Meaney
A breast phantom developed at the Supelec Institute was interrogated to study its suitability for microwave tomography measurements. A microwave measurement system based on 16 monopole antennas and a vector network analyzer was used to study how the S-parameters are influenced by insertion of the phantom. The phantom is a 3D-printed structure consisting of plastic shells that can be filled with tissue mimicking liquids. The phantom was filled with different liquids and tested with the measurement system to determine whether the plastic has any effects on the recovered images or not. Measurements of the phantom when it is filled with the same liquid as the surrounding coupling medium are of particular interest. In this case, the phantom plastic has a substantial effects on the measurements which ultimately detracts from the desired images.

5 March 2021 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
SHSamar Hosseinzadegan
Samar Hosseinzadegan
AFAndreas Fhager
Andreas Fhager
MPMikael Persson
Mikael Persson
SGShireen Geimer
Shireen Geimer
PMPaul Meaney
Paul Meaney
This article describes a fast microwave tomography reconstruction algorithm based on the 2-D discrete dipole approximation (DDA). Synthetic data from a finite-element-based solver and experimental data from a microwave imaging system are used to reconstruct images and to validate the algorithm. The microwave measurement system consists of 16 monopole antennas immersed in a tank filled with lossy coupling liquid and a vector network analyzer. The low-profile antennas and lossy nature of the system make the DDA an ideal forward solver in image reconstructions. The results show that the algorithm can readily reconstruct a 2-D plane of a cylindrical phantom. The proposed forward solver combined with the nodal adjoint method for computing the Jacobian matrix enables the algorithm to reconstruct an image within 6 s. This implementation provides significant time savings and reduced memory requirements and is a dramatic improvement over previous implementations.

9 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
AFAndreas Fhager
Andreas Fhager
SCStefan Candefjord
Stefan Candefjord
MEMikael Elam
Mikael Elam
MPMikael Persson
Mikael Persson
Early, preferably prehospital, detection of intracranial bleeding after trauma or stroke would dramatically improve the acute care of these large patient groups. In this paper, we use simulated microwave transmission data to investigate the performance of a machine learning classification algorithm based on subspace distances for the detection of intracranial bleeding. A computational model, consisting of realistic human head models of patients with bleeding, as well as healthy subjects, was inserted in an antenna array model. The Finite-Difference Time-Domain (FDTD) method was then used to generate simulated transmission coefficients between all possible combinations of antenna pairs. These transmission data were used both to train and evaluate the performance of the classification algorithm and to investigate its ability to distinguish patients with versus without intracranial bleeding. We studied how classification results were affected by the number of healthy subjects and patients used to train the algorithm, and in particular, we were interested in investigating how many samples were needed in the training dataset to obtain classification results better than chance. Our results indicated that at least 200 subjects, i.e., 100 each of the healthy subjects and bleeding patients, were needed to obtain classification results consistently better than chance (p < 0.05 using Student’s t-test). The results also showed that classification results improved with the number of subjects in the training data. With a sample size that approached 1000 subjects, classifications results characterized as area under the receiver operating curve (AUC) approached 1.0, indicating very high sensitivity and specificity.

17 March 2008 in Inverse Problems
Verified
Journal Article
Closed access
SNSven Nordebo
Sven Nordebo
AFAndreas Fhager
Andreas Fhager
MGMats Gustafsson
Mats Gustafsson
MPMikael Persson
Mikael Persson