Ben Potter

Dr. Ben Potter


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2014 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
MRMatthew Rowe
Matthew Rowe
TYTimur Yunusov
Timur Yunusov
Stephen HabenStephen Haben
Stephen Haben
CSColin Singleton
Colin Singleton
WHWilliam Holderbaum
William Holderbaum
BPBen Potter
Ben Potter
Reinforcing the Low Voltage (LV) distribution network will become essential to ensure it remains within its operating constraints as demand on the network increases. The deployment of energy storage in the distribution network provides an alternative to conventional reinforcement. This paper presents a control methodology for energy storage to reduce peak demand in a distribution network based on day-ahead demand forecasts and historical demand data. The control methodology pre-processes the forecast data prior to a planning phase to build in resilience to the inevitable errors between the forecasted and actual demand. The algorithm uses no real time adjustment so has an economical advantage over traditional storage control algorithms. Results show that peak demand on a single phase of a feeder can be reduced even when there are differences between the forecasted and the actual demand. In particular, results are presented that demonstrate when the algorithm is applied to a large number of single phase demand aggregations that it is possible to identify which of these aggregations are the most suitable candidates for the control methodology.

30 May 2014 in Energies
Verified
Journal Article
Open access
PDF file
MRMatthew Rowe
Matthew Rowe
TYTimur Yunusov
Timur Yunusov
Stephen HabenStephen Haben
Stephen Haben
William HolderbaumWilliam Holderbaum
William Holderbaum
BPBen Potter
Ben Potter
Energy storage is a potential alternative to conventional network reinforcement of the low voltage (LV) distribution network to ensure the grid’s infrastructure remains within its operating constraints. This paper presents a study on the control of such storage devices, owned by distribution network operators. A deterministic model predictive control (MPC) controller and a stochastic receding horizon controller (SRHC) are presented, where the objective is to achieve the greatest peak reduction in demand, for a given storage device specification, taking into account the high level of uncertainty in the prediction of LV demand. The algorithms presented in this paper are compared to a standard set-point controller and bench marked against a control algorithm with a perfect forecast. A specific case study, using storage on the LV network, is presented, and the results of each algorithm are compared. A comprehensive analysis is then carried out simulating a large number of LV networks of varying numbers of households. The results show that the performance of each algorithm is dependent on the number of aggregated households. However, on a typical aggregation, the novel SRHC algorithm presented in this paper is shown to outperform each of the comparable storage control techniques.

1 March 2013 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
MHMichael Hallworth
Michael Hallworth
BPBen Potter
Ben Potter
SSSeyed Ali Shirsavar
Seyed Ali Shirsavar
The phase‐shift full‐bridge (PSFB) converter allows high‐efficiency power conversion at high frequencies through zero voltage switching (ZVS); the parasitic drain‐to‐source capacitance of the metal‐oxide semiconductor field‐effect transistor is discharged by a resonant inductance before the switch is gated resulting in near zero turn‐on switching losses. Typically, an extra inductance is added to the leakage inductance of a transformer to form the resonant inductance necessary to charge and discharge the parasitic capacitances of the PSFB converter. However, many PSFB models do not consider the effects of the magnetising inductance or dead‐time in selecting the resonant inductance required to achieve ZVS. The choice of resonant inductance is crucial to the ZVS operation of the PSFB converter. Incorrectly sized resonant inductance will not achieve ZVS or will limit the load regulation ability of the converter. This study presents a unique and accurate equation for calculating the resonant inductance required to achieve ZVS over a wide load range incorporating the effects of the magnetising inductance and dead‐time. The derived equations are validated against PSPICE simulations of a PSFB converter and extensive hardware experimentations.

1 November 2006 in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
Verified
Conference Paper
Closed access
BPBen Potter
Ben Potter
SSS. A. Shirsavar
S. A. Shirsavar
This paper describes the design, implementation and characterisation of a contactless power transfer system for rotating applications. The power transfer system is based upon a zero-voltage-switched, full-bridge, DC-DC converter, but utilises a non-standard transformer. This transformer allows power transfer between its primary and secondary windings while also allowing free rotation between these windings. The aim of this research is to develop a solution that could replace mechanical slip-rings in certain applications where a non-contacting system would be advantageous. Based upon the design method presented in this paper, a 2 kW prototype system is constructed. Results obtained from testing the 2 kW prototype are presented and discussed. This discussion considers how the performance of the transformer varies with rotation and also the overall efficiency of the system

13 October 2015 in Energies
Verified
Journal Article
Open access
PDF file
CMCharles Moorey
Charles Moorey
William HolderbaumWilliam Holderbaum
William Holderbaum
BPBen Potter
Ben Potter
The efficiency of a Wireless Power Transfer (WPT) system is greatly dependent on both the geometry and operating frequency of the transmitting and receiving structures. By using Coupled Mode Theory (CMT), the figure of merit is calculated for resonantly-coupled loop and dipole systems. An in-depth analysis of the figure of merit is performed with respect to the key geometric parameters of the loops and dipoles, along with the resonant frequency, in order to identify the key relationships leading to high-efficiency WPT. For systems consisting of two identical single-turn loops, it is shown that the choice of both the loop radius and resonant frequency are essential in achieving high-efficiency WPT. For the dipole geometries studied, it is shown that the choice of length is largely irrelevant and that as a result of their capacitive nature, low-MHz frequency dipoles are able to produce significantly higher figures of merit than those of the loops considered. The results of the figure of merit analysis are used to propose and subsequently compare two mid-range loop and dipole WPT systems of equal size and operating frequency, where it is shown that the dipole system is able to achieve higher efficiencies than the loop system of the distance range examined.

1 January 2013
Verified
Conference Paper
Closed access
Stephen HabenStephen Haben
Stephen Haben
BPBen Potter
Ben Potter
CSC. Singleton
C. Singleton
PGP. Grindrod
P. Grindrod
WHW. Holderbaum
W. Holderbaum
DGD.V. Greetham
D.V. Greetham