JIN-OH HAHN

Dr. JIN-OH HAHN

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2015 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
JHJIN-OH HAHN
JIN-OH HAHN
OIOmer Inan
Omer Inan
LMLalit K. Mestha
Lalit K. Mestha
CKChang-Sei Kim
Chang-Sei Kim
SKSurvi Kyal
Survi Kyal
Ubiquitous blood pressure (BP) monitoring is needed to improve hypertension detection and control and is becoming feasible due to recent technological advances such as in wearable sensing. Pulse transit time (PTT) represents a well-known potential approach for ubiquitous BP monitoring. The goal of this review is to facilitate the achievement of reliable ubiquitous BP monitoring via PTT. We explain the conventional BP measurement methods and their limitations; present models to summarize the theory of the PTT-BP relationship; outline the approach while pinpointing the key challenges; overview the previous work toward putting the theory to practice; make suggestions for best practice and future research; and discuss realistic expectations for the approach.

7 March 2018 in Science Translational Medicine
Verified
Journal Article
Closed access
PDF file
ACAnand Chandrasekhar
Anand Chandrasekhar
CKChang-Sei Kim
Chang-Sei Kim
MNMohammed Naji
Mohammed Naji
KNKeerthana Natarajan
Keerthana Natarajan
JHJIN-OH HAHN
JIN-OH HAHN
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
High blood pressure (BP) is a major cardiovascular risk factor that is treatable, yet hypertension awareness and control rates are low. Ubiquitous BP monitoring technology could improve hypertension management, but existing devices require an inflatable cuff and are not compatible with such anytime, anywhere measurement of BP. We extended the oscillometric principle, which is used by most automatic cuff devices, to develop a cuff-less BP monitoring device using a smartphone. As the user presses her/his finger against the smartphone, the external pressure of the underlying artery is steadily increased while the phone measures the applied pressure and resulting variable-amplitude blood volume oscillations. A smartphone application provides visual feedback to guide the amount of pressure applied over time via the finger pressing and computes systolic and diastolic BP from the measurements. We prospectively tested the smartphone-based device for real-time BP monitoring in human subjects to evaluate usability (n = 30) and accuracy against a standard automatic cuff-based device (n = 32). We likewise tested a finger cuff device, which uses the volume-clamp method of BP detection. About 90% of the users learned the finger actuation required by the smartphone-based device after one or two practice trials. The device yielded bias and precision errors of 3.3 and 8.8 mmHg for systolic BP and −5.6 and 7.7 mmHg for diastolic BP over a 40 to 50 mmHg range of BP. These errors were comparable to the finger cuff device. Cuff-less and calibration-free monitoring of systolic and diastolic BP may be feasible via a smartphone.

1 October 2024 in Journal of the American Heart Association
Verified
Journal Article
Open access
KSKaan Sel
Kaan Sel
DODeen Osman
Deen Osman
FZFatemeh Zare
Fatemeh Zare
SSSina Masoumi Shahrbabak
Sina Masoumi Shahrbabak
LBLaura Brattain
Laura Brattain
RJRoozbeh Jafari
Roozbeh Jafari
The past several decades have seen rapid advances in diagnosis and treatment of cardiovascular diseases and stroke, enabled by technological breakthroughs in imaging, genomics, and physiological monitoring, coupled with therapeutic interventions. We now face the challenge of how to (1) rapidly process large, complex multimodal and multiscale medical measurements; (2) map all available data streams to the trajectories of disease states over the patient's lifetime; and (3) apply this information for optimal clinical interventions and outcomes. Here we review new advances that may address these challenges using digital twin technology to fulfill the promise of personalized cardiovascular medical practice. Rooted in engineering mechanics and manufacturing, the digital twin is a virtual representation engineered to model and simulate its physical counterpart. Recent breakthroughs in scientific computation, artificial intelligence, and sensor technology have enabled rapid bidirectional interactions between the virtual‐physical counterparts with measurements of the physical twin that inform and improve its virtual twin, which in turn provide updated virtual projections of disease trajectories and anticipated clinical outcomes. Verification, validation, and uncertainty quantification builds confidence and trust by clinicians and patients in the digital twin and establishes boundaries for the use of simulations in cardiovascular medicine. Mechanistic physiological models form the fundamental building blocks of the personalized digital twin that continuously forecast optimal management of cardiovascular health using individualized data streams. We present exemplars from the existing body of literature pertaining to mechanistic model development for cardiovascular dynamics and summarize existing technical challenges and opportunities pertaining to the foundation of a digital twin.

9 August 2016 in Scientific Reports
Verified
Journal Article
Open access
CKChang-Sei Kim
Chang-Sei Kim
SOStephanie L. Ober
Stephanie L. Ober
MMM. Sean McMurtry
M. Sean McMurtry
BFBarry A. Finegan
Barry A. Finegan
OIOmer T. Inan
Omer T. Inan
JHJIN-OH HAHN
JIN-OH HAHN
For more than a century, it has been known that the body recoils each time the heart ejects blood into the arteries. These subtle cardiogenic body movements have been measured with increasingly convenient ballistocardiography (BCG) instruments over the years. A typical BCG measurement shows several waves, most notably the “I”, “J” and “K” waves. However, the mechanism for the genesis of these waves has remained elusive. We formulated a simple mathematical model of the BCG waveform. We showed that the model could predict the BCG waves as well as physiologic timings and amplitudes of the major waves. The validated model reveals that the principal mechanism for the genesis of the BCG waves is blood pressure gradients in the ascending and descending aorta. This new mechanistic insight may be exploited to allow BCG to realize its potential for unobtrusive monitoring and diagnosis of cardiovascular health and disease.

7 August 2002 in IEEE Transactions on Control Systems Technology
Verified
Journal Article
Closed access
JHJIN-OH HAHN
JIN-OH HAHN
RRR. Rajamani
R. Rajamani
LAL. Alexander
L. Alexander
Vehicle control systems such as collision avoidance, adaptive cruise control, and automated lane-keeping systems as well as ABS and stability control systems can benefit significantly from being made "road-adaptive." The estimation of tire-road friction coefficient at the wheels allows the control algorithm in such systems to adapt to external driving conditions. This paper develops a new tire-road friction coefficient estimation algorithm based on measurements related to the lateral dynamics of the vehicle. A lateral tire force model parameterized as a function of slip angle, friction coefficient, normal force and cornering stiffness is used. A real-time parameter identification algorithm that utilizes measurements from a differential global positioning system (DGPS) system and a gyroscope is used to identify the tire-road friction coefficient and cornering stiffness parameters of the tire. The advantage of the developed algorithm is that it does not require large longitudinal slip in order to provide reliable friction estimates. Simulation studies indicate that a parameter convergence rate of 1 s can be obtained. Experiments conducted on both dry and slippery road indicate that the algorithm can work very effectively in identifying a slippery road.

2 June 2015 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
CKChang-Sei Kim
Chang-Sei Kim
ACAndrew M. Carek
Andrew M. Carek
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
OIOmer T. Inan
Omer T. Inan
JHJIN-OH HAHN
JIN-OH HAHN
Goal: We tested the hypothesis that the ballistocardiogram (BCG) waveform could yield a viable proximal timing reference for measuring pulse transit time (PTT). Methods: From 15 healthy volunteers, we measured PTT as the time interval between BCG and a noninvasively measured finger blood pressure (BP) waveform. To evaluate the efficacy of the BCG-based PTT in estimating BP, we likewise measured pulse arrival time (PAT) using the electrocardiogram (ECG) as proximal timing reference and compared their correlations to BP. Results: BCG-based PTT was correlated with BP reasonably well: the mean correlation coefficient (r ) was 0.62 for diastolic (DP), 0.65 for mean (MP), and 0.66 for systolic (SP) pressures when the intersecting tangent method was used as distal timing reference. Comparing four distal timing references (intersecting tangent, maximum second derivative, diastolic minimum, and systolic maximum), PTT exhibited the best correlation with BP when the systolic maximum method was used (mean r value was 0.66 for DP, 0.67 for MP, and 0.70 for SP). PTT was more strongly correlated with DP than PAT regardless of the distal timing reference: mean r value was 0.62 versus 0.51 (p = 0.07) for intersecting tangent, 0.54 versus 0.49 (p = 0.17) for maximum second derivative, 0.58 versus 0.52 (p = 0.37) for diastolic minimum, and 0.66 versus 0.60 (p = 0.10) for systolic maximum methods. The difference between PTT and PAT in estimating DP was significant (p = 0.01) when the r values associated with all the distal timing references were compared altogether. However, PAT appeared to outperform PTT in estimating SP ( p = 0.31 when the r values associated with all the distal timing references were compared altogether). Conclusion: We conclude that BCG is an adequate proximal timing reference in deriving PTT, and that BCG-based PTT may be superior to ECG-based PAT in estimating DP. Significance: PTT with BCG as proximal timing reference has potential to enable convenient and ubiquitous cuffless BP monitoring.