Anas Tahir

Mr. Anas Tahir


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2021 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
Tawsifur RahmanTawsifur Rahman
Tawsifur Rahman
AKAmith Khandakar
Amith Khandakar
YQYazan Qiblawey
Yazan Qiblawey
ATAnas Tahir
Anas Tahir
Serkan KiranyazSerkan Kiranyaz
Serkan Kiranyaz
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury

30 October 2021 in Computers in Biology and Medicine
Verified
Journal Article
Open access
ATAnas Tahir
Anas Tahir
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
AKAmith Khandakar
Amith Khandakar
Tawsifur RahmanTawsifur Rahman
Tawsifur Rahman
YQYazan Qiblawey
Yazan Qiblawey
THTahir Hamid
Tahir Hamid
The immense spread of coronavirus disease 2019 (COVID-19) has left healthcare systems incapable to diagnose and test patients at the required rate. Given the effects of COVID-19 on pulmonary tissues, chest radiographic imaging has become a necessity for screening and monitoring the disease. Numerous studies have proposed Deep Learning approaches for the automatic diagnosis of COVID-19. Although these methods achieved outstanding performance in detection, they have used limited chest X-ray (CXR) repositories for evaluation, usually with a few hundred COVID-19 CXR images only. Thus, such data scarcity prevents reliable evaluation of Deep Learning models with the potential of overfitting. In addition, most studies showed no or limited capability in infection localization and severity grading of COVID-19 pneumonia. In this study, we address this urgent need by proposing a systematic and unified approach for lung segmentation and COVID-19 localization with infection quantification from CXR images. To accomplish this, we have constructed the largest benchmark dataset with 33,920 CXR images, including 11,956 COVID-19 samples, where the annotation of ground-truth lung segmentation masks is performed on CXRs by an elegant human-machine collaborative approach. An extensive set of experiments was performed using the state-of-the-art segmentation networks, U-Net, U-Net++, and Feature Pyramid Networks (FPN). The developed network, after an iterative process, reached a superior performance for lung region segmentation with Intersection over Union (IoU) of 96.11% and Dice Similarity Coefficient (DSC) of 97.99%. Furthermore, COVID-19 infections of various shapes and types were reliably localized with 83.05% IoU and 88.21% DSC. Finally, the proposed approach has achieved an outstanding COVID-19 detection performance with both sensitivity and specificity values above 99%.

20 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
AKAmith Khandakar
Amith Khandakar
KAKhawla Alzoubi
Khawla Alzoubi
SMSamar Mansoor
Samar Mansoor
ATAnas Tahir
Anas Tahir
NANasser Al-Emadi
Nasser Al-Emadi
One of the major causes of death all over the world is heart disease or cardiac dysfunction. These diseases could be identified easily with the variations in the sound produced due to the heart activity. These sophisticated auscultations need important clinical experience and concentrated listening skills. Therefore, there is an unmet need for a portable system for the early detection of cardiac illnesses. This paper proposes a prototype model of a smart digital-stethoscope system to monitor patient’s heart sounds and diagnose any abnormality in a real-time manner. This system consists of two subsystems that communicate wirelessly using Bluetooth low energy technology: A portable digital stethoscope subsystem, and a computer-based decision-making subsystem. The portable subsystem captures the heart sounds of the patient, filters and digitizes, and sends the captured heart sounds to a personal computer wirelessly to visualize the heart sounds and for further processing to make a decision if the heart sounds are normal or abnormal. Twenty-seven t-domain, f-domain, and Mel frequency cepstral coefficients (MFCC) features were used to train a public database to identify the best-performing algorithm for classifying abnormal and normal heart sound (HS). The hyper parameter optimization, along with and without a feature reduction method, was tested to improve accuracy. The cost-adjusted optimized ensemble algorithm can produce 97% and 88% accuracy of classifying abnormal and normal HS, respectively.

16 September 2020 in IEEE Open Journal of the Communications Society
Verified
Journal Article
Open access
AAAbdullateef Almohamad
Abdullateef Almohamad
ATAnas Tahir
Anas Tahir
AAAyman Al-Kababji
Ayman Al-Kababji
HFHaji M. Furqan
Haji M. Furqan
TKTamer Khattab
Tamer Khattab
HAHuseyin Arslan
Huseyin Arslan
With the emergence of the internet of things (IoT) technology, wireless connectivity should be more ubiquitous than ever. In fact, the availability of wireless connection everywhere comes with security threats that, unfortunately, cannot be handled by conventional cryptographic solutions alone, especially in heterogeneous and decentralized future wireless networks. In general, physical layer security (PLS) helps in bridging this gap by taking advantage of the fading propagation channel. Moreover, the adoption of reconfigurable intelligent surfaces (RIS) in wireless networks makes the PLS techniques more efficient by involving the channel into the design loop. In this paper, we conduct a comprehensive literature review on the RIS-assisted PLS for future wireless communications. We start by introducing the basic concepts of RISs and their different applications in wireless communication networks and the most common PLS performance metrics. Then, we focus on the review and classification of RIS-assisted PLS applications, exhibiting multiple scenarios, system models, objectives, and methodologies. In fact, most of the works in this field formulate an optimization problem to maximize the secrecy rate (SR) or secrecy capacity (SC) at a legitimate user by jointly optimizing the beamformer at the transmitter and the RIS’s coefficients, while the differences are in the adopted methodology to optimally/sub-optimally approach the solution. We finalize this survey by presenting some insightful recommendations and suggesting open problems for future research extensions.

15 November 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
NINabil Ibtehaz
Nabil Ibtehaz
Sakib MahmudSakib Mahmud
Sakib Mahmud
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
AKAmith Khandakar
Amith Khandakar
MKMuhammad Salman Khan
Muhammad Salman Khan
MRM. Sohel Rahman
M. Sohel Rahman
Cardiovascular diseases are one of the most severe causes of mortality, annually taking a heavy toll on lives worldwide. Continuous monitoring of blood pressure seems to be the most viable option, but this demands an invasive process, introducing several layers of complexities and reliability concerns due to non-invasive techniques not being accurate. This motivates us to develop a method to estimate the continuous arterial blood pressure (ABP) waveform through a non-invasive approach using Photoplethysmogram (PPG) signals. We explore the advantage of deep learning, as it would free us from sticking to ideally shaped PPG signals only by making handcrafted feature computation irrelevant, which is a shortcoming of the existing approaches. Thus, we present PPG2ABP, a two-stage cascaded deep learning-based method that manages to estimate the continuous ABP waveform from the input PPG signal with a mean absolute error of 4.604 mmHg, preserving the shape, magnitude, and phase in unison. However, the more astounding success of PPG2ABP turns out to be that the computed values of Diastolic Blood Pressure (DBP), Mean Arterial Pressure (MAP), and Systolic Blood Pressure (SBP) from the estimated ABP waveform outperform the existing works under several metrics (mean absolute error of 3.449 ± 6.147 mmHg, 2.310 ± 4.437 mmHg, and 5.727 ± 9.162 mmHg, respectively), despite that PPG2ABP is not explicitly trained to do so. Notably, both for DBP and MAP, we achieve Grade A in the BHS (British Hypertension Society) Standard and satisfy the AAMI (Association for the Advancement of Medical Instrumentation) standard.

17 May 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
YQYazan Qiblawey
Yazan Qiblawey
ATAnas Tahir
Anas Tahir
Muhammad E. H. ChowdhuryMuhammad E. H. Chowdhury
Muhammad E. H. Chowdhury
AKAmith Khandakar
Amith Khandakar
Serkan KiranyazSerkan Kiranyaz
Serkan Kiranyaz
MAMohamed Arselene Ayari
Mohamed Arselene Ayari
Detecting COVID-19 at an early stage is essential to reduce the mortality risk of the patients. In this study, a cascaded system is proposed to segment the lung, detect, localize, and quantify COVID-19 infections from computed tomography images. An extensive set of experiments were performed using Encoder–Decoder Convolutional Neural Networks (ED-CNNs), UNet, and Feature Pyramid Network (FPN), with different backbone (encoder) structures using the variants of DenseNet and ResNet. The conducted experiments for lung region segmentation showed a Dice Similarity Coefficient (DSC) of 97.19% and Intersection over Union (IoU) of 95.10% using U-Net model with the DenseNet 161 encoder. Furthermore, the proposed system achieved an elegant performance for COVID-19 infection segmentation with a DSC of 94.13% and IoU of 91.85% using the FPN with DenseNet201 encoder. The proposed system can reliably localize infections of various shapes and sizes, especially small infection regions, which are rarely considered in recent studies. Moreover, the proposed system achieved high COVID-19 detection performance with 99.64% sensitivity and 98.72% specificity. Finally, the system was able to discriminate between different severity levels of COVID-19 infection over a dataset of 1110 subjects with sensitivity values of 98.3%, 71.2%, 77.8%, and 100% for mild, moderate, severe, and critical, respectively.