This work presents a phase-locked loop (PLL) algorithm adequate for applications regarding single-phase power grids. The proposed approach is based on the correlation of the input signal with a complex one obtained from an adaptive filter aiming at minimizing computational burden and increase accuracy if compared with a former algorithm previously proposed in literature. Thus it is possible to obtain high disturbance rejection, especially when dealing with the presence of subharmonics and interharmonics in the frequency spectrum of the supply voltage. Performance is thoroughly evaluated through experimental tests considering both steady-state and dynamic behaviors, while a proper comparison is established with other similar solutions.
This work aims to analyze and validate through mathematical modeling and experimental results, in a three-phase three-wire electrical system, the technical viability of a static power converter with a two-level topology with only two controlled branches (2L2B), operating as a grid-side converter (GSC) in a wind turbine generator based on a doubly fed induction generator (DFIG). With this reduced-switches topology, the GSC is able to regulate the DC-link voltage level from the generator back-to-back converter and provide ancillary services of harmonic filtering and reactive power compensation from linear/nonlinear loads connected to the point of common coupling. An 8-kVA experimental prototype was implemented in the laboratory to validate the proposal. The prototype control system was realized using the dSPACE DS1103 PPC Controller Board platform programmed via MATLAB/Simulink. The effectiveness of the proposed system is verified by comparing the results obtained with the 2L2B topology to the ones with the usual two-level three-branch topology.
Currently, power quality is a major issue for all sorts of customers. End users of the electricity service in industrial, commercial and residential sectors have nonlinear loads or loads that are sensitive to disturbances in the electric power supply. In this context, this paper presents a study on four different control strategies for the application of synchronous compensator based on a doubly-fed induction generator (DFIG). The mathematical modeling developed to support the proposal of this article is validated through computational simulations and experimental results. This work contains strong arguments that support the idea that the proposed synchronous compensator can be employed to cancel oscillations caused by imbalances in the grid, and can furthermore inject or absorb reactive and active power without the characteristic oscillations that arise when negative sequence components are present in the system.
1 March 2021 in International Journal of Electrical Power & Energy Systems