Sandor Bernad

Dr. Sandor Bernad

Romanian Academy – Timisoara Branch, Center for Fundamental and Advanced Technical Research, 130004 Timisoara, Romania
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
GZGEORGE LUCIAN ZORILĂ
GEORGE LUCIAN ZORILĂ
RCRăzvan Grigoraș Căpitănescu
Răzvan Grigoraș Căpitănescu
RDRoxana Cristina Dragusin
Roxana Cristina Dragusin
AIAnca-Maria Istrate-Ofiteru
Anca-Maria Istrate-Ofiteru
Elena BernadElena Bernad
Elena Bernad
Dominic Gabriel IliescuDominic Gabriel Iliescu
Dominic Gabriel Iliescu
Objective: Omentum involvement resulting from uterine perforation is a rare complication following intrauterine procedures that might require immediate intervention due to severe ischemic consequences. This review examines the prevalence of this complication, risk factors, the mode and timing of diagnosis, the proper management and the outcome. Methods: A systematic literature search was conducted on PubMed, PubMed Central and Scopus using uterine perforation, D&C, abortion and omentum as keywords. The exclusion criteria included the presence of the uterus or placenta’s malignancy and uterine perforation following delivery or caused by an intrauterine device. Results: The review included 11 articles from 133 screened papers. We identified 12 cases that three evaluators further analysed. We also present the case of a 32-year-old woman diagnosed with uterine perforation and omentum involvement. The patient underwent a hysteroscopic procedure with resectioning the protruding omentum into the uterine cavity, followed by intrauterine device insertion. Conclusion: This paper highlights the importance of a comprehensive gynaecological evaluation following a D&C procedure that includes a thorough clinical examination and a detailed ultrasound assessment. Healthcare providers should not overlook the diagnosis of omentum involvement in the presence of a history of intrauterine procedures.

9 July 2019 in Molecules
Verified
Journal Article
Open access
PDF file
SBSandor Bernad
Sandor Bernad
DSDaniela Susan-Resiga
Daniela Susan-Resiga
EBElena S. Bernad
Elena S. Bernad
The present study investigated the possibilities and feasibility of drug targeting for an arterial bifurcation lesion to influence the host healing response. A micrometer sized iron particle was used only to model the magnetic carrier in the experimental investigation (not intended for clinical use), to demonstrate the feasibility of the particle targeting at the lesion site and facilitate the new experimental investigations using coated superparamagnetic iron oxide nanoparticles. Magnetic fields were generated by a single permanent external magnet (ferrite magnet). Artery bifurcation exerts severe impacts on drug distribution, both in the main vessel and the branches, practically inducing an uneven drug concentration distribution in the bifurcation lesion area. There are permanently positioned magnets in the vicinity of the bifurcation near the diseased area. The generated magnetic field induced deviation of the injected ferromagnetic particles and were captured onto the vessel wall of the test section. To increase the particle accumulation in the targeted region and consequently avoid the polypharmacology (interaction of the injected drug particles with multiple target sites), it is critical to understand flow hemodynamics and the correlation between flow structure, magnetic field gradient, and spatial position.

14 September 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
ATAlin TOTOREAN
Alin TOTOREAN
ITIuliana-Claudia TOTOREAN
Iuliana-Claudia TOTOREAN
SBSandor Bernad
Sandor Bernad
TCTiberiu Ciocan
Tiberiu Ciocan
DMDaniel Malita
Daniel Malita
Elena BernadElena Bernad
Elena Bernad
The complicated abdominal aorta and its branches are a portion of the circulatory system prone to developing atherosclerotic plaque and aneurysms. These disorders are closely connected to the changing blood flow environment that the area’s complicated architecture produces (between celiac artery and iliac artery bifurcation); this phenomenon is widespread at arterial bifurcations. Based on computed tomography angiography (CTA) scans, this current work offers a numerical analysis of a patient-specific reconstruction of the abdominal aorta and its branches to identify and emphasize the most likely areas to develop atherosclerosis. The simulations were run following the heart cycle and under physiological settings. The wall shear stress (WSS), velocity field, and streamlines were examined. According to the findings, complex flow is primarily present at the location of arterial bifurcations, where abnormal flow patterns create recirculation zones with low and fluctuating WSS (<0.5 Pa), which are known to affect endothelial homeostasis and cause adverse vessel remodeling. The study provides a patient-specific hemodynamic analysis model, which couples in vivo CT imaging with in silico simulation under physiological circumstances. The study offers quantitative data on the range fluctuations of important hemodynamic parameters, such as WSS and recirculation region expansion, which are directly linked to the onset and progression of atherosclerosis. The findings could also help drug targeting at this vascular level by understanding blood flow patterns in the abdominal aorta and its branches.

25 October 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
SBSandor Bernad
Sandor Bernad
Elena BernadElena Bernad
Elena Bernad
This study presents preliminary computational and experimental findings on two alternative permanent magnet configurations helpful for magnetic drug administration in vivo. A numerical simulation and a direct experimental measurement of the magnetic induction on the magnet system’s surface were used to map the magnetic field. In addition, the ferrite-type (grade Y35) and permanent neodymium magnets (grade N52) to produce powerful magnetic forces were also examined analytically and quantitatively. Ansys-Maxwell software and Finite Element Method Magnetism (FEMM) version 4.2 were used for all numerical computations in the current investigation. For both magnets, the generated magnetic fields were comparatively studied for targeting Fe particles having a diameter of 6 μm. The following findings were drawn from the present investigation: (i) the particle deposition on the vessel wall is greatly influenced by the intensity of the magnetic field, the magnet type, the magnet size, and the magnetic characteristics of the micro-sized magnetic particles (MSMPs); (ii) ferrite-type magnets might be employed to deliver magnetoresponsive particles to a target location, even if they are less powerful than neodymium magnets; and (iii) the results from the Computational Fluid Dynamics( CFD) models agree well with the measured magnetic field induction, magnetic field strength, and their fluctuation with the distance from the magnet surface.

12 September 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
SBSandor Bernad
Sandor Bernad
VSVlad Mircea Socoliuc
Vlad Mircea Socoliuc
DSDaniela Susan-Resiga
Daniela Susan-Resiga
Izabella CraciunescuIzabella Craciunescu
Izabella Craciunescu
Rodica TurcuRodica Turcu
Rodica Turcu
Elena BernadElena Bernad
Elena Bernad
Drug therapy for vascular disease has been promoted to inhibit angiogenesis in atherosclerotic plaques and prevent restenosis following surgical intervention. This paper investigates the arterial depositions and distribution of PEG-functionalized magnetic nanocomposite clusters (PEG_MNCs) following local delivery in a stented artery model in a uniform magnetic field produced by a regionally positioned external permanent magnet; also, the PEG_MNCs aggregation or chain formation in and around the implanted stent. The central concept is to employ one external permanent magnet system, which produces enough magnetic field to magnetize and guide the magnetic nanoclusters in the stented artery region. At room temperature (25 °C), optical microscopy of the suspension model’s aggregation process was carried out in the external magnetic field. According to the optical microscopy pictures, the PEG_MNC particles form long linear aggregates due to dipolar magnetic interactions when there is an external magnetic field. During magnetic particle targeting, 20 mL of the model suspensions are injected (at a constant flow rate of 39.6 mL/min for the period of 30 s) by the syringe pump in the mean flow (flow velocity is Um = 0.25 m/s, corresponding to the Reynolds number of Re = 232) into the stented artery model. The PEG_MNC clusters are attracted by the magnetic forces (generated by the permanent external magnet) and captured around the stent struts and the bottom artery wall before and inside the implanted stent. The colloidal interaction among the MNC clusters was investigated by calculating the electrostatic repulsion, van der Waals and magnetic dipole-dipole energies. The current work offers essential details about PEG_MNCs aggregation and chain structure development in the presence of an external magnetic field and the process underlying this structure formation.

1 January 2014 in Bio-Medical Materials and Engineering
Verified
Journal Article
Closed access
PDF file
Elena BernadElena Bernad
Elena Bernad
SBSandor Bernad
Sandor Bernad
MCMarius L. Craina
Marius L. Craina
In this study, effects of serial stenosis on coronary hemodynamics were investigated in the human right coronary artery (RCA) using blood flow analysis. A 3-D model of a serial stenosed RCA was reconstructed based on multislice computerized tomography images. Numerical analysis examined the effect of multiple serial stenoses on the hemodynamic characteristics such as flow separation, pressure drop and FFR. Pressure loss associated with flow expansion after each constriction was large. Overall pressure drop increased from 1700 Pa (12.75 mmHg) at the end diastole to 11000 Pa (82.5 mmHg) at the peak systole. In two stenoses the corresponding pressure gradients werearound 30 mmHg and corresponded to the stenosis with FFR < 0.7 (associated to the sever stenosis). Severe stenosies caused large pressure drops across the throat. Blood flow distal to the stenosis was associated with fluctuations of the wall shear stress and vorticity.