Izabella Craciunescu

Dr. Izabella Craciunescu

National Institute for Research and Development of Isotopic and Molecular Technologies Cluj-Napoca, Romania
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
APAlexandra Pusta
Alexandra Pusta
Mihaela TertişMihaela Tertiş
Mihaela Tertiş
Izabella CraciunescuIzabella Craciunescu
Izabella Craciunescu
Rodica TurcuRodica Turcu
Rodica Turcu
SMSimona Maria Mirel
Simona Maria Mirel
Cecilia CristeaCecilia Cristea
Cecilia Cristea
With the predicted rise in the incidence of cancer, there is an ever-growing need for new cancer treatment strategies. Recently, magnetic nanoparticles have stood out as promising nanostructures for imaging and drug delivery systems as they possess unique properties. Moreover, magnetic nanomaterials functionalized with other compounds can lead to multicomponent nanoparticles with innovative structures and synergetic performance. The incorporation of chemotherapeutic drugs or RNA in magnetic drug delivery systems represents a promising alternative that can increase efficiency and reduce the side effects of anticancer therapy. This review presents a critical overview of the recent literature concerning the advancements in the field of magnetic nanoparticles used in drug delivery, with a focus on their classification, characteristics, synthesis and functionalization methods, limitations, and examples of magnetic drug delivery systems incorporating chemotherapeutics or RNA.

12 May 2021 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
Izabella CraciunescuIzabella Craciunescu
Izabella Craciunescu
PPPetru Palade
Petru Palade
NINicuşor Iacob
Nicuşor Iacob
GIGeorge Marian Ispas
George Marian Ispas
ASAnda Elena Stanciu
Anda Elena Stanciu
RTRodica Paula Turcu
Rodica Paula Turcu

4 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
CZCristian Zaharia
Cristian Zaharia
Virgil-Florin DumaVirgil-Florin Duma
Virgil-Florin Duma
Cosmin SinescuCosmin Sinescu
Cosmin Sinescu
VSVlad Mircea Socoliuc
Vlad Mircea Socoliuc
Izabella CraciunescuIzabella Craciunescu
Izabella Craciunescu
Meda-Lavinia NegrutiuMeda-Lavinia Negrutiu
Meda-Lavinia Negrutiu
Dental adhesives are used in a wide range of applications, including to place direct composite restorations in frontal or posterior teeth. One of the most frequent causes for the failure of composite resin restorations is microleakages. The first aim of this work is to introduce a new type of self-etched dental adhesive doped with magnetic nanoparticles (MPs) synthetized in the laboratory. The scope is to produce adhesives with a minimized width/thickness to decrease the risk of microleakages. The second aim is to assess the width/thickness of the adhesive layer in all the characteristic areas of the teeth using both the less precise but most common optical microscopy and the more accurate and volumetric micro-Computed Tomography (CT) investigations. Twenty extracted teeth have been divided into four groups: Group 1 includes ‘blank’ samples with adhesives that are not doped with MPs; Group 2 includes samples with adhesives doped with MPs; Groups 3 and 4 include samples with adhesives doped with MPs that are subjected to an active magnetic field for 5 and 10 min, respectively. Microscopy investigations followed by micro-CT and EDAX are performed on the adhesive. While a rather good agreement is obtained between the microscopy and micro-CT results, the capability of the latter to offer a full volumetric reconstruction of the layer is exploited to analyze the adhesion of the four considered dental materials. Thus, from micro-CT results the graphs of the surface areas as functions of the adhesive layer width are modeled mathematically, as well as the volume of sealants, for each of the four groups. To our knowledge, it is the first time that such a methodology is used. Characteristic parameters are extracted and the ascertainment of the optimal parameter that should be utilized for such assessments is discussed. The study demonstrates the adhesion improvement produced for Groups 3 and 4, where MPs are used. It also concludes that the magnetic field should be applied to the adhesive material for the longest possible exposure time (with a trade-off with the clinical duration of the treatment).

12 September 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
SBSandor Bernad
Sandor Bernad
VSVlad Mircea Socoliuc
Vlad Mircea Socoliuc
DSDaniela Susan-Resiga
Daniela Susan-Resiga
Izabella CraciunescuIzabella Craciunescu
Izabella Craciunescu
Rodica TurcuRodica Turcu
Rodica Turcu
Elena BernadElena Bernad
Elena Bernad
Drug therapy for vascular disease has been promoted to inhibit angiogenesis in atherosclerotic plaques and prevent restenosis following surgical intervention. This paper investigates the arterial depositions and distribution of PEG-functionalized magnetic nanocomposite clusters (PEG_MNCs) following local delivery in a stented artery model in a uniform magnetic field produced by a regionally positioned external permanent magnet; also, the PEG_MNCs aggregation or chain formation in and around the implanted stent. The central concept is to employ one external permanent magnet system, which produces enough magnetic field to magnetize and guide the magnetic nanoclusters in the stented artery region. At room temperature (25 °C), optical microscopy of the suspension model’s aggregation process was carried out in the external magnetic field. According to the optical microscopy pictures, the PEG_MNC particles form long linear aggregates due to dipolar magnetic interactions when there is an external magnetic field. During magnetic particle targeting, 20 mL of the model suspensions are injected (at a constant flow rate of 39.6 mL/min for the period of 30 s) by the syringe pump in the mean flow (flow velocity is Um = 0.25 m/s, corresponding to the Reynolds number of Re = 232) into the stented artery model. The PEG_MNC clusters are attracted by the magnetic forces (generated by the permanent external magnet) and captured around the stent struts and the bottom artery wall before and inside the implanted stent. The colloidal interaction among the MNC clusters was investigated by calculating the electrostatic repulsion, van der Waals and magnetic dipole-dipole energies. The current work offers essential details about PEG_MNCs aggregation and chain structure development in the presence of an external magnetic field and the process underlying this structure formation.

25 August 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MSMaria Suciu
Maria Suciu
CMClaudiu Mirescu
Claudiu Mirescu
Izabella CraciunescuIzabella Craciunescu
Izabella Craciunescu
GMGabriel Sergiu Gabriel MACAVEI
Gabriel Sergiu Gabriel MACAVEI
CLCristian Leostean
Cristian Leostean
Lucian Barbu-TudoranLucian Barbu-Tudoran
Lucian Barbu-Tudoran
The in vivo distribution of 50 nm clusters of polyethylene glycol-conjugated superparamagnetic iron oxide nanoparticles (SPIONs-PEG) was conducted in this study. SPIONs-PEG were synthesized de novo, and their structure and paramagnetic behaviors were analyzed by specific methods (TEM, DLS, XRD, VSM). Wistar rats were treated with 10 mg Fe/kg body weight SPIONs-PEG and their organs and blood were examined at two intervals for short-term (15, 30, 60, 180 min) and long-term (6, 12, 24 h) exposure evaluation. Most exposed organs were investigated through light and transmission electron microscopy, and blood and urine samples were examined through fluorescence spectrophotometry. SPIONs-PEG clusters entered the bloodstream after intraperitoneal and intravenous administrations and ended up in the urine, with the highest clearance at 12 h. The skin and spleen were within normal histological parameters, while the liver, kidney, brain, and lungs showed signs of transient local anoxia or other transient pathological affections. This study shows that once internalized, the synthesized SPIONs-PEG disperse well through the bloodstream with minor to nil induced tissue damage, are biocompatible, have good clearance, and are suited for biomedical applications.

29 March 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Izabella CraciunescuIzabella Craciunescu
Izabella Craciunescu
GIGeorge Marian Ispas
George Marian Ispas
ACAlexandra Ciorita
Alexandra Ciorita
CLCristian Leostean
Cristian Leostean
EIErzsébet ILLÉS
Erzsébet ILLÉS
Rodica TurcuRodica Turcu
Rodica Turcu
In general, magnetic nanoparticles are not often used in dental applications due to some limitations of these materials, such as aggregation problems and low mechanical and chemical resistance but also esthetic problems due to their black color. Our research presents the synthesis of novel magnetic dental composite materials based on magnetic nanoparticles, functionalized and properly coated to overcome the limitations of using magnetic nanoparticles in dental applications. The composites were prepared using a preparation flow containing several integrated reaction steps used previously sequentially. An adequate and deep characterization of dental magnetic composites has been carried out in order to demonstrate that each limitation has been successfully overcome. It was proved that each component brings particular benefits in dental interventions: Fe3O4 nanoparticles have biocompatible, non-toxic properties and also antimicrobial effects; the SiO2 layer significantly increases the mechanical strength of the material; and the Ca(OH)2 layer initiates local calcification and significantly improves the color of the dental composite material. Due to magnetic properties, an innovative application approach on the tooth surface can be achieved under an external magnetic field, which, compared to conventional methods, has a major impact on reducing the occurrence of dental caries under filling materials as well as on reducing microfractures.