The physiological processes and mechanisms of an arterial system are complex and subtle. Physics-based models have been proven to be a very useful tool to simulate actual physiological behavior of the arteries. The current physics-based models include high-dimensional models (2D and 3D models) and low-dimensional models (0D, 1D and tube-load models). High-dimensional models can describe the local hemodynamic information of arteries in detail. With regard to an exact model of the whole arterial system, a high-dimensional model is computationally impracticable since the complex geometry, viscosity or elastic properties and complex vectorial output need to be provided. For low-dimensional models, the structure, centerline and viscosity or elastic properties only need to be provided. Therefore, low-dimensional modeling with lower computational costs might be a more applicable approach to represent hemodynamic properties of the entire arterial system and these three types of low-dimensional models have been extensively used in the study of cardiovascular dynamics. In recent decades, application of physics-based models to estimate central aortic pressure has attracted increasing interest. However, to our best knowledge, there has been few review paper about reconstruction of central aortic pressure using these physics-based models. In this paper, three types of low-dimensional physical models (0D, 1D and tube-load models) of systemic arteries are reviewed, the application of three types of models on estimation of central aortic pressure is taken as an example to discuss their advantages and disadvantages, and the proper choice of models for specific researches and applications are advised.
This study investigates the potential of the limb ballistocardiogram (BCG) for unobtrusive estimation of cardiovascular (CV) parameters. In conjunction with the reference CV parameters (including diastolic, pulse, and systolic pressures, stroke volume, cardiac output, and total peripheral resistance), an upper-limb BCG based on an accelerometer embedded in a wearable armband and a lower-limb BCG based on a strain gauge embedded in a weighing scale were instrumented simultaneously with a finger photoplethysmogram (PPG). To standardize the analysis, the more convenient yet unconventional armband BCG was transformed into the more conventional weighing scale BCG (called the synthetic weighing scale BCG) using a signal processing procedure. The characteristic features were extracted from these BCG and PPG waveforms in the form of wave-to-wave time intervals, wave amplitudes, and wave-to-wave amplitudes. Then, the relationship between the characteristic features associated with (i) the weighing scale BCG-PPG pair and (ii) the synthetic weighing scale BCG-PPG pair versus the CV parameters, was analyzed using the multivariate linear regression analysis. The results indicated that each of the CV parameters of interest may be accurately estimated by a combination of as few as two characteristic features in the upper-limb or lower-limb BCG, and also that the characteristic features recruited for the CV parameters were to a large extent relevant according to the physiological mechanism underlying the BCG.
Arterial stiffness is an important risk factor for cardiovascular events. Radial augmentation index (AIr) can be more conveniently measured compared with carotid-femoral pulse wave velocity (cfPWV). However, the performance ofAIrin assessing arterial stiffness is limited. This study proposes a novel indexAIrd, a combination ofAIrand diastolic augmentation index (AId) with a weightα, to achieve better performance overAIrin assessing arterial stiffness. 120 subjects (43 ± 21 years old) were enrolled. The best-fitαis determined by the best correlation coefficient betweenAIrdandcfPWV. The performance of the method was tested using the 12-fold cross validation method.AIrd(r = 0.68,P < 0.001) shows a stronger correlation withcfPWVand a narrower prediction interval thanAIr(r = 0.61,P < 0.001),AId(r = −0.17,P = 0.06), the central augmentation index (AIc) (r = 0.61,P < 0.001) orAIcnormalized for heart rate of 75 bpm (r = 0.65,P < 0.001). Compared withAIr(age,P < 0.001; gender,P < 0.001; heart rate,P < 0.001; diastolic blood pressure,P < 0.001; weight,P = 0.001),AIrdhas fewer confounding factors (age,P < 0.001; gender,P < 0.001). In conclusion,AIrdderives performance improvement in assessing arterial stiffness, with a stronger correlation withcfPWVand fewer confounding factors.
23 May 2022 in IEEE Transactions on Biomedical Engineering
Objective: Preterm birth is the leading cause of morbidity and mortality involving over 10% of infants. Tools for timely diagnosis of preterm birth are lacking and the underlying physiological mechanisms are unclear. The aim of the present study is to improve early assessment of pregnancy progression by combining and optimizing a large number of electrohysterography (EHG) features with a dedicated machine learning framework. Methods: A set of reported EHG features are extracted. In addition, novel cross and multichannel entropy and mutual information are employed. The optimal feature set is selected using a wrapper method according to the accuracy of the leave-one-out cross validation. An annotated database of 74 EHG recordings in women with preterm contractions was employed to test the ability of the proposed method to recognize the onset of labor and the risk of preterm birth. Difference between using the contractile segments only and the whole EHG signal was compared. Results: The proposed method produces an accuracy of 96.4% and 90.5% for labor and preterm prediction, respectively, much higher than that reported in previous studies. The best labor prediction was observed with the contraction segments and the best preterm prediction achieved with the whole EHG signal. Entropy features, particularly the newly-employed cross entropy contribute significantly to the optimal feature set for both labor and preterm prediction. Significance: Our results suggest that changes in the EHG, particularly the regularity, might manifest early in pregnancy. Single-channel and cross entropy may therefore provide relevant prognostic opportunities for pregnancy monitoring.
26 April 2023 in Biomedical Signal Processing and Control