Azin Sadat Mousavi

Azin Sadat Mousavi

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 July 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PYPeyman Yousefian
Peyman Yousefian
Sungtae ShinSungtae Shin
Sungtae Shin
AMAzin Sadat Mousavi
Azin Sadat Mousavi
CKChang-Sei Kim
Chang-Sei Kim
RMRamakrishna Mukkamala
Ramakrishna Mukkamala
JHJIN-OH HAHN
JIN-OH HAHN
The goal of this study was to investigate the potential of wearable limb ballistocardiography (BCG) to enable cuff-less blood pressure (BP) monitoring, by investigating the association between wearable limb BCG-based pulse transit time (PTT) and BP. A wearable BCG-based PTT was calculated using the BCG and photoplethysmogram (PPG) signals acquired by a wristband as proximal and distal timing reference (called the wrist PTT). Its efficacy as surrogate of BP was examined in comparison with PTT calculated using the whole-body BCG acquired by a customized weighing scale (scale PTT) as well as pulse arrival time (PAT) using the experimental data collected from 22 young healthy participants under multiple BP-perturbing interventions. The wrist PTT exhibited close association with both diastolic (group average r = 0.79; mean absolute error (MAE) = 5.1 mmHg) and systolic (group average r = 0.81; MAE = 7.6 mmHg) BP. The efficacy of the wrist PTT was superior to scale PTT and PAT for both diastolic and systolic BP. The association was consistent and robust against diverse BP-perturbing interventions. The wrist PTT showed superior association with BP when calculated with green PPG rather than infrared PPG. In sum, wearable limb BCG has the potential to realize convenient cuff-less BP monitoring via PTT.

30 July 2020 in IEEE Access
Verified
Journal Article
Open access
PYPeyman Yousefian
Peyman Yousefian
Sungtae ShinSungtae Shin
Sungtae Shin
AMAzin Sadat Mousavi
Azin Sadat Mousavi
ATAli Tivay
Ali Tivay
CKChang-Sei Kim
Chang-Sei Kim
JHJIN-OH HAHN
JIN-OH HAHN
The objective of this study was to investigate the efficacy of pulse transit time (PTT)-pulse wave analysis (PWA) fusion in cuff-less blood pressure (BP) trend tracking based on the wearable wrist ballistocardiogram (BCG). We constructed PTT and 36 candidate BCG PWA features based on the BCG and photoplethysmogram (PPG) signals acquired at the wrist. We performed a model-based analysis to select 6 candidate BCG PWA features most sensitive to BP. We aggregated the 6 BCG PWA features into novel predictors of diastolic, systolic, and pulse BP (DP, SP, and PP) orthogonal to PTT by covariance-maximizing dimensionality reduction. Then, we evaluated and compared the efficacy of BCG PTT and BCG PTT-PWA fusion in tracking the trend of DP, SP, and PP. Unique innovations of this study, generalizable to a range of physiological signals beyond the BCG, are (i) the systematic selection of PWA features based on model-based analysis and (ii) the development of PWA-based BP predictors orthogonal to PTT. Using the experimental wrist BCG and PPG signals collected from 23 human subjects, we demonstrated that (i) BCG PTT-PWA fusion may significantly outperform BCG PTT; (ii) PTT may play the primary role in tracking BP while BCG PWA features may still have an independent and complementary value (especially in tracking PP); and (iii) model-based selection of BCG PWA features can enhance the robustness of BP trend tracking based on BCG PTT-PWA fusion.

1 July 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YYYang Yao
Yang Yao
Sungtae ShinSungtae Shin
Sungtae Shin
AMAzin Sadat Mousavi
Azin Sadat Mousavi
CKChang-Sei Kim
Chang-Sei Kim
LXLisheng Xu
Lisheng Xu
JHJIN-OH HAHN
JIN-OH HAHN
This study investigates the potential of the limb ballistocardiogram (BCG) for unobtrusive estimation of cardiovascular (CV) parameters. In conjunction with the reference CV parameters (including diastolic, pulse, and systolic pressures, stroke volume, cardiac output, and total peripheral resistance), an upper-limb BCG based on an accelerometer embedded in a wearable armband and a lower-limb BCG based on a strain gauge embedded in a weighing scale were instrumented simultaneously with a finger photoplethysmogram (PPG). To standardize the analysis, the more convenient yet unconventional armband BCG was transformed into the more conventional weighing scale BCG (called the synthetic weighing scale BCG) using a signal processing procedure. The characteristic features were extracted from these BCG and PPG waveforms in the form of wave-to-wave time intervals, wave amplitudes, and wave-to-wave amplitudes. Then, the relationship between the characteristic features associated with (i) the weighing scale BCG-PPG pair and (ii) the synthetic weighing scale BCG-PPG pair versus the CV parameters, was analyzed using the multivariate linear regression analysis. The results indicated that each of the CV parameters of interest may be accurately estimated by a combination of as few as two characteristic features in the upper-limb or lower-limb BCG, and also that the characteristic features recruited for the CV parameters were to a large extent relevant according to the physiological mechanism underlying the BCG.

26 March 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PYPeyman Yousefian
Peyman Yousefian
Sungtae ShinSungtae Shin
Sungtae Shin
AMAzin Sadat Mousavi
Azin Sadat Mousavi
CKChang-Sei Kim
Chang-Sei Kim
BFBarry Finegan
Barry Finegan
JHJIN-OH HAHN
JIN-OH HAHN
By virtue of its direct association with the cardiovascular (CV) functions and compatibility to unobtrusive measurement during daily activities, the limb ballistocardiogram (BCG) is receiving an increasing interest as a viable means for ultra-convenient CV health and disease monitoring. However, limited insights on its physical implications have hampered disciplined interpretation of the BCG and systematic development of the BCG-based approaches for CV health monitoring. In this study, a mathematical model that can predict the limb BCG in responses to the arterial blood pressure (BP) waves in the aorta was developed and experimentally validated. The validated mathematical model suggests that (i) the limb BCG waveform reveals the timings and amplitudes associated with the aortic BP waves; (ii) mechanical filtering exerted by the musculoskeletal properties of the body can obscure the manifestation of the arterial BP waves in the limb BCG; and (iii) the limb BCG exhibits meaningful morphological changes in response to the alterations in the CV risk predictors. The physical insights garnered by the analysis of the mathematical model may open up new opportunities toward next generation of the BCG-based CV healthcare techniques embedded with transparency, interpretability, and robustness against the external variability.

15 May 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
JPJesse D. Parreira
Jesse D. Parreira
Yekanth Ram ChalumuriYekanth Ram Chalumuri
Yekanth Ram Chalumuri
AMAzin Sadat Mousavi
Azin Sadat Mousavi
MMMihir Modak
Mihir Modak
YZYuanyuan Zhou
Yuanyuan Zhou
JHJIN-OH HAHN
JIN-OH HAHN

1 July 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
Sungtae ShinSungtae Shin
Sungtae Shin
AMAzin Sadat Mousavi
Azin Sadat Mousavi
SLSophia Lyle
Sophia Lyle
EJElisabeth Jang
Elisabeth Jang
PYPeyman Yousefian
Peyman Yousefian
JHJIN-OH HAHN
JIN-OH HAHN
Objective: Toward the ultimate goal of robust cuff-less blood pressure (BP) tracking with wrist wearables against postural changes, the goal of this work was to investigate posture-dependent variability in pulse transit time (PTT) measured with ballistocardiogram (BCG) and photoplethysmogram (PPG) signal pair at the wrist. Methods: BCG and PPG signals were acquired from 25 subjects under the combination of 3 body (standing, sitting, and supine) and 3 arm (vertical in head-to-foot direction, placed on the chest, and holding a shoulder) postures. PTT was computed as the time interval between the BCG J wave and the PPG foot, and the impact of the 9 postures on PTT was analyzed by invoking an array of possible physical mechanisms. Results: Our work suggests that (i) wrist BCG-PPG PTT is consistent under standing and sitting postures with vertically held arms; and (ii) changes in wrist orientation and height as well as restrictions in body and arm movement may alter wrist BCG-PPG PTT via distortions in the wrist BCG and PPG waveforms. The results indicate that wrist BCG-PPG PTT varies with respect to postures even when BP remains constant. Conclusion: The potential of cuff-less BP tracking via wrist BCG-PPG PTT demonstrated under standing posture with arms vertically down in the head-to-foot direction may not generalize to other body and arm postures. Significance: Understanding the physical mechanisms responsible for posture-induced BCG-PPG PTT variability may increase the versatility of the wrist BCG for cuff-less BP tracking.